Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 41

Question 400

An ACI endpoint attaches to a leaf interface but never receives its expected VLAN encapsulation because the domain is not bound to the access policy chain. The team is preparing a controlled production change and must preserve fabric reachability. What should the engineer do first to address the observed failure?

  1. Reconcile the VMM domain association, hypervisor inventory and EPG port-group mapping.
  2. Verify the VLAN pool, domain, AEP and interface policy group associations serving the endpoint port.
  3. Configure and validate an appropriate first-hop redundancy group with a shared virtual gateway and healthy tracking.
  4. Validate fabric discovery prerequisites, physical connectivity and node registration in APIC.

Explanation

Correct Answer

B:

Verify the VLAN pool, domain, AEP and interface policy group associations serving the endpoint port. ACI access policies rely on a consistent domain and attachment chain before deploying the correct encapsulation. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Reconcile the VMM domain association, hypervisor inventory and EPG port-group mapping. That response is associated with aci vmm association rather than the specific aci access policy chain condition described here. For the stated failure, the preferred action is: Verify the VLAN pool, domain, AEP and interface policy group associations serving the endpoint port. Relevant evidence: Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults. The team is preparing a controlled production change and must preserve fabric reachability.

C:

Configure and validate an appropriate first-hop redundancy group with a shared virtual gateway and healthy tracking. This concerns first-hop gateway failover, not aci access policy chain.

D:

Validate fabric discovery prerequisites, physical connectivity and node registration in APIC. That response is associated with aci fabric discovery rather than the specific aci access policy chain condition described here. For the stated failure, the preferred action is: Verify the VLAN pool, domain, AEP and interface policy group associations serving the endpoint port. Relevant evidence: Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults. The team is preparing a controlled production change and must preserve fabric reachability.

Question 401

A new MDS FC port channel comes up with only one member while the remaining ports are suspended. A storage change board requires a traceable diagnosis before allowing further fabric changes. What should the operator avoid assuming from the observed state?

  1. Forcing suspended links into service without correcting compatibility can destabilize a SAN fabric.
  2. Renaming device aliases does not resolve an underlying Fibre Channel domain ID conflict.
  3. Assuming that every local command is distributed automatically can leave peers inconsistent.
  4. A target LUN mapping cannot repair a failed physical or fabric login on the initiator port.

Explanation

Correct Answer

A:

Forcing suspended links into service without correcting compatibility can destabilize a SAN fabric. Fibre Channel port channels bundle compatible physical links; inconsistent member configuration can suspend interfaces. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

B:

Renaming device aliases does not resolve an underlying Fibre Channel domain ID conflict. That response is associated with fcid and domain id stability rather than the specific fibre channel port-channel consistency condition described here. For the stated failure, the preferred action is: Align interface speed, VSAN mode and compatibility parameters across the intended port-channel members. Relevant evidence: Inspect SAN port-channel summary, member compatibility results, link speeds and VSAN assignments. A storage change board requires a traceable diagnosis before allowing further fabric changes.

C:

Assuming that every local command is distributed automatically can leave peers inconsistent. This concerns cisco fabric services distribution, not fibre channel port-channel consistency.

D:

A target LUN mapping cannot repair a failed physical or fabric login on the initiator port. That response is associated with fibre channel fabric login rather than the specific fibre channel port-channel consistency condition described here. For the stated failure, the preferred action is: Align interface speed, VSAN mode and compatibility parameters across the intended port-channel members. Relevant evidence: Inspect SAN port-channel summary, member compatibility results, link speeds and VSAN assignments. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Question 402

A storage administrator zones a host using a node name although the fabric login is registered with a different port identifier. A storage change board requires a traceable diagnosis before allowing further fabric changes. What is the best next implementation or troubleshooting step?

  1. Correlate SAN-specific health and interface telemetry in supported Nexus Dashboard or MDS monitoring tools.
  2. Align trunk allowed VSANs and verify the operational VSAN membership end to end.
  3. Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets.
  4. Use the correct initiator and target port WWPNs when creating the required zone memberships.

Explanation

Correct Answer

D:

Use the correct initiator and target port WWPNs when creating the required zone memberships. Fibre Channel port WWNs identify individual interfaces used by fabric login and zoning policies. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Correlate SAN-specific health and interface telemetry in supported Nexus Dashboard or MDS monitoring tools. This concerns nexus dashboard SAN monitoring, not wwpn versus wwnn.

B:

Align trunk allowed VSANs and verify the operational VSAN membership end to end. That response is associated with vsan trunk mismatch rather than the specific wwpn versus wwnn condition described here. For the stated failure, the preferred action is: Use the correct initiator and target port WWPNs when creating the required zone memberships. Relevant evidence: Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. A storage change board requires a traceable diagnosis before allowing further fabric changes.

C:

Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. That response is associated with vsan isolation rather than the specific wwpn versus wwnn condition described here. For the stated failure, the preferred action is: Use the correct initiator and target port WWPNs when creating the required zone memberships. Relevant evidence: Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Question 403

A virtualized host can ping the iSCSI target interface but discovers no storage sessions after a switch change. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What should the engineer collect before ruling out other causes?

  1. Inspect target portal IPs, IQN access rules, CHAP policy, TCP reachability and multipath sessions.
  2. Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs.
  3. Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs.
  4. Inspect alias database, recorded target WWPNs, zones using the alias and change approvals.

Explanation

Correct Answer

A:

Inspect target portal IPs, IQN access rules, CHAP policy, TCP reachability and multipath sessions. These records help distinguish the suspected failure from a superficially similar fault before modifying production. iSCSI uses IP transport and initiator-target session controls rather than Fibre Channel fabric login. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.

Incorrect Answers

B:

Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. This concerns VSAN isolation, not iscsi target discovery.

C:

Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. This concerns npv uplink fabric services, not iscsi target discovery.

D:

Inspect alias database, recorded target WWPNs, zones using the alias and change approvals. This concerns device alias maintenance, not iscsi target discovery.

Question 404

A fabric dashboard displays healthy switch reachability but a service experiences consistent high-latency paths. The team is preparing a controlled production change and must preserve fabric reachability. What should the operator avoid assuming from the observed state?

  1. Expanding import targets indiscriminately can leak routes across security and tenancy boundaries.
  2. An overall green dashboard health score does not guarantee all application paths perform normally.
  3. Forcing every redundant port to forward would create a bridging loop rather than improve resilience.
  4. LACP negotiation cannot compensate for incompatible allowed VLAN or switching-mode settings.

Explanation

Correct Answer

B:

An overall green dashboard health score does not guarantee all application paths perform normally. Fabric assurance tools combine topology and operational observations but require data correlation to identify service causes. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Expanding import targets indiscriminately can leak routes across security and tenancy boundaries. This concerns mp-BGP tenant route import, not nexus dashboard fabric visibility.

C:

Forcing every redundant port to forward would create a bridging loop rather than improve resilience. This concerns rstp blocked uplink, not nexus dashboard fabric visibility.

D:

LACP negotiation cannot compensate for incompatible allowed VLAN or switching-mode settings. This concerns lacp member mismatch, not nexus dashboard fabric visibility.

Question 405

An orchestration service retries a configuration POST after timeout and produces duplicate resources on a Nexus management controller. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. Which limitation prevents the team from overgeneralizing this result?

  1. A timeout is not proof that the server failed to apply the initial request.
  2. A script that runs without raising a Python exception can still produce an invalid monitoring conclusion.
  3. Adding GPUs alone will not solve a fabric bottleneck and may increase east-west network pressure.
  4. Network connectivity and a valid TLS session do not imply permission for every API operation.

Explanation

Correct Answer

A:

A timeout is not proof that the server failed to apply the initial request. Retrying non-idempotent create operations without state checks can duplicate resources after ambiguous timeouts. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.

Incorrect Answers

B:

A script that runs without raising a Python exception can still produce an invalid monitoring conclusion. This concerns on-box python exception handling, not rest api retries and idempotence.

C:

Adding GPUs alone will not solve a fabric bottleneck and may increase east-west network pressure. This concerns ai cluster network congestion, not rest api retries and idempotence.

D:

Network connectivity and a valid TLS session do not imply permission for every API operation. This concerns nx-api request authorization, not rest api retries and idempotence.

Question 406

An engineer plans simultaneous firmware activation on every blade supporting a critical cluster with no evacuation plan. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which observations would best validate the initial diagnosis?

  1. Inspect cluster failover capacity, target firmware policy, activation impact and host migration status.
  2. Inspect effective vNIC templates, VLAN object assignments, LAN uplink trunk allowances and fault logs.
  3. Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables.
  4. Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding.

Explanation

Correct Answer

A:

Inspect cluster failover capacity, target firmware policy, activation impact and host migration status. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Rolling hardware maintenance reduces service disruption only if dependent workloads can tolerate sequential host removal. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

B:

Inspect effective vNIC templates, VLAN object assignments, LAN uplink trunk allowances and fault logs. This concerns UCS VLAN pool and template, not UCS firmware change sequencing.

C:

Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables. This concerns UCS mac pool uniqueness, not UCS firmware change sequencing.

D:

Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding. This concerns UCS fabric redundancy, not UCS firmware change sequencing.

Question 407

An unexpected Fibre Channel switch joins a SAN ISL and begins participating in fabric services. Security engineering must restore the approved service without relaxing unrelated protection. What information should be inspected before the change is applied?

  1. Inspect switch WWN bindings, ISL neighbors, fabric membership and enforcement violation logs.
  2. Inspect assigned user roles, AAA server attributes, command authorization and audit logs.
  3. Inspect port-security policy, learned WWPNs, interface events and attempted fabric logins.
  4. Inspect role definitions, AAA authorization, zone management privileges and administrative audit logs.

Explanation

Correct Answer

A:

Inspect switch WWN bindings, ISL neighbors, fabric membership and enforcement violation logs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Fabric binding controls which fabric switches are allowed to join trusted SAN connections. Security engineering must restore the approved service without relaxing unrelated protection.

Incorrect Answers

B:

Inspect assigned user roles, AAA server attributes, command authorization and audit logs. This concerns nx-os administrative RBAC, not fabric binding membership.

C:

Inspect port-security policy, learned WWPNs, interface events and attempted fabric logins. This concerns fibre channel port security, not fabric binding membership.

D:

Inspect role definitions, AAA authorization, zone management privileges and administrative audit logs. This concerns mds SAN administrative control, not fabric binding membership.

Question 408

Latency-sensitive storage traffic shares uplinks with a large backup flow and drops rise during congestion. Operations is validating the host before approving production workload placement. What should the operator avoid assuming from the observed state?

  1. A storage-array LUN mapping cannot make an offline UCS SAN uplink carry the vHBA frames.
  2. Changing the displayed server name does not resolve a duplicate effective network identifier.
  3. An FC link up indication alone cannot prove that the boot LUN is authorized and reachable.
  4. A high-priority label inside UCS does not guarantee every upstream switch honors that class.

Explanation

Correct Answer

D:

A high-priority label inside UCS does not guarantee every upstream switch honors that class. QoS treatment is effective only when marking, queue allocation and congestion behavior align across involved devices. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

A storage-array LUN mapping cannot make an offline UCS SAN uplink carry the vHBA frames. That response is associated with san connectivity from blade chassis rather than the specific ucs network qos policy condition described here. For the stated failure, the preferred action is: Review UCS QoS classes and upstream priority handling across the entire network path. Relevant evidence: Inspect vNIC QoS policies, DCB settings if applicable, interface queue drops and upstream class maps. Operations is validating the host before approving production workload placement.

B:

Changing the displayed server name does not resolve a duplicate effective network identifier. That response is associated with ucs mac pool uniqueness rather than the specific ucs network qos policy condition described here. For the stated failure, the preferred action is: Review UCS QoS classes and upstream priority handling across the entire network path. Relevant evidence: Inspect vNIC QoS policies, DCB settings if applicable, interface queue drops and upstream class maps. Operations is validating the host before approving production workload placement.

C:

An FC link up indication alone cannot prove that the boot LUN is authorized and reachable. This concerns SAN boot path policy, not UCS network qos policy.

Question 409

An operations platform polls hundreds of leaf switches too slowly to detect short control-plane events. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which explanation most directly accounts for the required correction?

  1. With peer-link failure and a reachable peer, the secondary suspends vPC member ports to prevent loops and dual-active forwarding.
  2. VXLAN encapsulation depends on routable IP transport between VTEP endpoints before tenant traffic can traverse it.
  3. Integrated routing and bridging requires consistent L3 VNI and tenant routing context for inter-subnet forwarding.
  4. Model-driven telemetry can provide pushed state updates more frequently than coarse periodic polling.

Explanation

Correct Answer

D:

Model-driven telemetry can provide pushed state updates more frequently than coarse periodic polling. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

With peer-link failure and a reachable peer, the secondary suspends vPC member ports to prevent loops and dual-active forwarding. This concerns vpc peer-link recovery, not streaming telemetry health.

B:

VXLAN encapsulation depends on routable IP transport between VTEP endpoints before tenant traffic can traverse it. This concerns vxlan vtep underlay reachability, not streaming telemetry health.

C:

Integrated routing and bridging requires consistent L3 VNI and tenant routing context for inter-subnet forwarding. This concerns evpn vni-to-vrf mapping, not streaming telemetry health.

Question 410

An Intersight user has authorization to restart one lab server but can also deploy profiles to production organizations. Security engineering must restore the approved service without relaxing unrelated protection. Which qualification should the change record include?

  1. Enabling only an ARP inspection check may not validate every IP data packet's source identity.
  2. Increasing OSPF dead timers does not make incompatible authentication keys acceptable.
  3. Trusting all access ports would negate the primary protection against unauthorized DHCP servers.
  4. A role that appears read-only in one organization may still carry changes rights in another assigned scope.

Explanation

Correct Answer

D:

A role that appears read-only in one organization may still carry changes rights in another assigned scope. Intersight RBAC and organizational scoping define which managed resources an operator may control. Security engineering must restore the approved service without relaxing unrelated protection.

Incorrect Answers

A:

Enabling only an ARP inspection check may not validate every IP data packet's source identity. This concerns first-hop ip/mac spoof defense, not intersight scoped operations.

B:

Increasing OSPF dead timers does not make incompatible authentication keys acceptable. This concerns routing protocol keychain rollover, not intersight scoped operations.

C:

Trusting all access ports would negate the primary protection against unauthorized DHCP servers. This concerns DHCP snooping trusted uplink, not intersight scoped operations.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.