Question 380
A Linux workload can reach an NFS server by IP but receives access denied when mounting its application share. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which evidence set most directly tests the suspected failure?
- Inspect export paths, permitted clients, protocol version, mount request and server logs.
- Inspect SAN port-channel summary, member compatibility results, link speeds and VSAN assignments.
- Inspect MDS platform release notes, EPLD package compatibility, reload dependencies and alternate paths.
- Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events.
Explanation
Correct Answer
A:Inspect export paths, permitted clients, protocol version, mount request and server logs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. NFS file access is controlled by network and export permissions, not Fibre Channel zoning. A storage change board requires a traceable diagnosis before allowing further fabric changes.
Incorrect Answers
B:Inspect SAN port-channel summary, member compatibility results, link speeds and VSAN assignments. This concerns fibre channel port-channel consistency, not nfs export permissions.
C:Inspect MDS platform release notes, EPLD package compatibility, reload dependencies and alternate paths. This concerns mds epld update impact, not nfs export permissions.
D:Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events. This concerns fibre channel fabric login, not nfs export permissions.
Question 381
A UCS blade chassis appears in inventory but several blades remain undiscovered after an I/O module replacement. Operations is validating the host before approving production workload placement. What post-change observation gives the strongest evidence of success?
- Only the approved profile scope receives the tested update, with unrelated services preserved.
- Traffic remains available across a controlled single-fabric interruption with expected failover behavior.
- The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface.
- All expected blades appear in managed inventory without persistent IOM fault alarms.
Explanation
Correct Answer
D:All expected blades appear in managed inventory without persistent IOM fault alarms. This result tests the original failure rather than reporting merely that the configuration command was accepted. The blade chassis depends on a healthy IOM and fabric-interconnect management path to discover and service blades. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:Only the approved profile scope receives the tested update, with unrelated services preserved. This concerns updating service-profile templates, not UCS blade chassis IOM discovery.
B:Traffic remains available across a controlled single-fabric interruption with expected failover behavior. That response is associated with ucs fabric redundancy rather than the specific ucs blade chassis iom discovery condition described here. For the stated failure, the preferred action is: Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities. Relevant evidence: Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs. Operations is validating the host before approving production workload placement.
C:The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface. That response is associated with ucs vlan pool and template rather than the specific ucs blade chassis iom discovery condition described here. For the stated failure, the preferred action is: Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities. Relevant evidence: Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs. Operations is validating the host before approving production workload placement.
Question 382
A Nexus switch upgrade has been described as nondisruptive, but the running hardware and target image are not confirmed as ISSU compatible. The team is preparing a controlled production change and must preserve fabric reachability. What should the engineer do first to address the observed failure?
- Collect and analyze supported flow telemetry from the relevant interfaces and time interval.
- Mirror the relevant ingress and egress traffic to a secured analyzer with a valid SPAN configuration.
- Validate fabric discovery prerequisites, physical connectivity and node registration in APIC.
- Run the supported compatibility and impact checks and plan an outage if an ISSU path is not qualified.
Explanation
Correct Answer
D:Run the supported compatibility and impact checks and plan an outage if an ISSU path is not qualified. Nondisruptive software upgrade support is platform, topology and image-path dependent and must be verified. The team is preparing a controlled production change and must preserve fabric reachability.
Incorrect Answers
A:Collect and analyze supported flow telemetry from the relevant interfaces and time interval. This concerns netflow traffic attribution, not nexus issu eligibility.
B:Mirror the relevant ingress and egress traffic to a secured analyzer with a valid SPAN configuration. This concerns span packet-level diagnosis, not nexus issu eligibility.
C:Validate fabric discovery prerequisites, physical connectivity and node registration in APIC. This concerns aci fabric discovery, not nexus issu eligibility.
Question 383
A new Nexus switch starts Power On Auto Provisioning but stalls after DHCP because the boot image URL is unreachable. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. Which result would best confirm that the remediation worked?
- A second run against an unchanged fabric reports no material differences and service tests remain stable.
- The completed script retrieves the full authorized inventory across every page with no repeated identifiers.
- The plan lists only intended devices and the deployment audit matches those targets without collateral changes.
- The device retrieves verified artifacts and applies the approved initial configuration successfully.
Explanation
Correct Answer
D:The device retrieves verified artifacts and applies the approved initial configuration successfully. This result tests the original failure rather than reporting merely that the configuration command was accepted. POAP bootstrap depends on correct discovery and reachable provisioning artifacts, not DHCP completion alone. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.
Incorrect Answers
A:A second run against an unchanged fabric reports no material differences and service tests remain stable. This concerns ansible idempotent templates, not poap bootstrap dependencies.
B:The completed script retrieves the full authorized inventory across every page with no repeated identifiers. This concerns python api pagination, not poap bootstrap dependencies.
C:The plan lists only intended devices and the deployment audit matches those targets without collateral changes. This concerns nexus dashboard automation scope, not poap bootstrap dependencies.
Question 384
An Intersight user has authorization to restart one lab server but can also deploy profiles to production organizations. Security engineering must restore the approved service without relaxing unrelated protection. Why is the targeted engineering response justified in this situation?
- Intersight RBAC and organizational scoping define which managed resources an operator may control.
- FC port security can restrict which device WWNs are permitted to connect through designated fabric ports.
- Storage network RBAC limits configuration actions independently of physical access to SAN switches.
- Fabric binding controls which fabric switches are allowed to join trusted SAN connections.
Explanation
Correct Answer
A:Intersight RBAC and organizational scoping define which managed resources an operator may control. Security engineering must restore the approved service without relaxing unrelated protection.
Incorrect Answers
B:FC port security can restrict which device WWNs are permitted to connect through designated fabric ports. This concerns fibre channel port security, not intersight scoped operations.
C:Storage network RBAC limits configuration actions independently of physical access to SAN switches. This concerns mds SAN administrative control, not intersight scoped operations.
D:Fabric binding controls which fabric switches are allowed to join trusted SAN connections. This concerns fabric binding membership, not intersight scoped operations.
Question 385
A VXLAN VTEP can ping peers but no EVPN address-family neighbor is established and remote MAC/IP routes are absent. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which observations would best validate the initial diagnosis?
- Inspect PIM neighbors, RP mapping, join state and reverse-path-forwarding interfaces.
- Inspect affected path topology, fabric insights, health anomalies and matching device performance timelines.
- Check IPv6 link-local addresses, OSPFv3 interface participation, area settings and protocol packets.
- Inspect EVPN BGP neighbor state, advertised Type-2 routes, route targets and the corresponding VNI.
Explanation
Correct Answer
D:Inspect EVPN BGP neighbor state, advertised Type-2 routes, route targets and the corresponding VNI. These records help distinguish the suspected failure from a superficially similar fault before modifying production. EVPN distributes MAC and IP reachability using MP-BGP; underlay IP reachability alone cannot populate those bindings. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.
Incorrect Answers
A:Inspect PIM neighbors, RP mapping, join state and reverse-path-forwarding interfaces. This concerns PIM multicast rendezvous point, not mp-BGP evpn route learning.
B:Inspect affected path topology, fabric insights, health anomalies and matching device performance timelines. This concerns nexus dashboard fabric visibility, not mp-BGP evpn route learning.
C:Check IPv6 link-local addresses, OSPFv3 interface participation, area settings and protocol packets. This concerns ospfv3 IPv6 neighbor discovery, not mp-BGP evpn route learning.
Question 386
An Ansible fabric playbook reports hundreds of changed interfaces on every run even when no administrator intended a configuration change. The automation change must pass a preproduction test and leave a verifiable audit trail. Which intervention most directly addresses the stated condition?
- Validate the DHCP options, image/script availability and bootstrap transport path before restarting POAP.
- Implement documented pagination and response-error handling in the inventory API client.
- Replace non-idempotent imperative commands with state-aware configuration modules and diff-based validation where supported.
- Use NX-OS scheduling capability with the appropriate job definition and maintenance safeguards.
Explanation
Correct Answer
C:Replace non-idempotent imperative commands with state-aware configuration modules and diff-based validation where supported. Declarative, state-aware automation should converge on the desired configuration without producing repeated unnecessary changes. The automation change must pass a preproduction test and leave a verifiable audit trail.
Incorrect Answers
A:Validate the DHCP options, image/script availability and bootstrap transport path before restarting POAP. That response is associated with poap bootstrap dependencies rather than the specific ansible idempotent templates condition described here. For the stated failure, the preferred action is: Replace non-idempotent imperative commands with state-aware configuration modules and diff-based validation where supported. Relevant evidence: Inspect Ansible change output, module behavior, running configurations and intended-state version control. The automation change must pass a preproduction test and leave a verifiable audit trail.
B:Implement documented pagination and response-error handling in the inventory API client. That response is associated with python api pagination rather than the specific ansible idempotent templates condition described here. For the stated failure, the preferred action is: Replace non-idempotent imperative commands with state-aware configuration modules and diff-based validation where supported. Relevant evidence: Inspect Ansible change output, module behavior, running configurations and intended-state version control. The automation change must pass a preproduction test and leave a verifiable audit trail.
D:Use NX-OS scheduling capability with the appropriate job definition and maintenance safeguards. This concerns nx-os scheduler jobs, not ansible idempotent templates.
Question 387
A new Fibre Channel host is connected to an MDS switch but never receives a fabric identifier and cannot discover targets. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which result would best confirm that the remediation worked?
- Domain IDs become unique and stable, fabric merge completes and attached initiators retain valid paths.
- Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets.
- All expected FC interfaces are active members and fabric traffic remains available after a link failure.
- The initiator appears in FLOGI with an FCID and can proceed to authorized name-server discovery.
Explanation
Correct Answer
D:The initiator appears in FLOGI with an FCID and can proceed to authorized name-server discovery. This result tests the original failure rather than reporting merely that the configuration command was accepted. An initiator must complete fabric login and receive an FCID before normal fabric services can identify it. A storage change board requires a traceable diagnosis before allowing further fabric changes.
Incorrect Answers
A:Domain IDs become unique and stable, fabric merge completes and attached initiators retain valid paths. That response is associated with fcid and domain id stability rather than the specific fibre channel fabric login condition described here. For the stated failure, the preferred action is: Validate physical FC link and initiator FLOGI registration before changing storage-array masking. Relevant evidence: Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events. A storage change board requires a traceable diagnosis before allowing further fabric changes.
B:Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets. This concerns npv uplink fabric services, not fibre channel fabric login.
C:All expected FC interfaces are active members and fabric traffic remains available after a link failure. That response is associated with fibre channel port-channel consistency rather than the specific fibre channel fabric login condition described here. For the stated failure, the preferred action is: Validate physical FC link and initiator FLOGI registration before changing storage-array masking. Relevant evidence: Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events. A storage change board requires a traceable diagnosis before allowing further fabric changes.
Question 388
A fabric interconnect has never exported its current UCS configuration despite recent service-profile and policy changes. Operations is validating the host before approving production workload placement. Which controlled change is most appropriate given the evidence?
- Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks.
- Review UCS QoS classes and upstream priority handling across the entire network path.
- Create and secure an appropriate management configuration backup before a major maintenance operation.
- Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities.
Explanation
Correct Answer
C:Create and secure an appropriate management configuration backup before a major maintenance operation. UCS configuration backups retain recovery information for policies and identities and should accompany approved changes. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. This concerns SAN connectivity from blade chassis, not UCS management backup.
B:Review UCS QoS classes and upstream priority handling across the entire network path. This concerns UCS network qos policy, not UCS management backup.
D:Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities. This concerns wwpn pool allocation, not UCS management backup.
Question 389
Layer 2 VXLAN segments work but traffic between tenant IP subnets fails because the L3 VNI is associated with the wrong VRF. The team is preparing a controlled production change and must preserve fabric reachability. What information should be inspected before the change is applied?
- Inspect VNI-to-VRF mappings, NVE membership, route targets and tenant route tables.
- Inspect loopback addresses, underlay routes, tunnel source settings and VTEP reachability.
- Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults.
- Inspect fabric membership, node discovery events, infra connectivity and APIC registration details.
Explanation
Correct Answer
A:Inspect VNI-to-VRF mappings, NVE membership, route targets and tenant route tables. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Integrated routing and bridging requires consistent L3 VNI and tenant routing context for inter-subnet forwarding. The team is preparing a controlled production change and must preserve fabric reachability.
Incorrect Answers
B:Inspect loopback addresses, underlay routes, tunnel source settings and VTEP reachability. This concerns vxlan vtep underlay reachability, not evpn vni-to-vrf mapping.
C:Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults. This concerns aci access policy chain, not evpn vni-to-vrf mapping.
D:Inspect fabric membership, node discovery events, infra connectivity and APIC registration details. This concerns aci fabric discovery, not evpn vni-to-vrf mapping.
Question 390
A leaf learns EVPN prefixes from a neighbor but cannot install remote tenant routes because the received route targets are not imported. The team is preparing a controlled production change and must preserve fabric reachability. Which limitation prevents the team from overgeneralizing this result?
- A working keepalive is not a replacement data path for the vPC peer-link.
- An FHRP cannot repair a host's incorrect default gateway or disconnected Layer 2 segment.
- Expanding import targets indiscriminately can leak routes across security and tenancy boundaries.
- An RP mapping correction will not compensate for broken RPF reachability to the multicast source.
Explanation
Correct Answer
C:Expanding import targets indiscriminately can leak routes across security and tenancy boundaries. MP-BGP session establishment does not guarantee tenant routes will be imported when policy attributes mismatch. The team is preparing a controlled production change and must preserve fabric reachability.
Incorrect Answers
A:A working keepalive is not a replacement data path for the vPC peer-link. This concerns vpc peer-link recovery, not mp-BGP tenant route import.
B:An FHRP cannot repair a host's incorrect default gateway or disconnected Layer 2 segment. This concerns first-hop gateway failover, not mp-BGP tenant route import.
D:An RP mapping correction will not compensate for broken RPF reachability to the multicast source. This concerns PIM multicast rendezvous point, not mp-BGP tenant route import.
Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests