Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 42

Question 410

An Intersight user has authorization to restart one lab server but can also deploy profiles to production organizations. Security engineering must restore the approved service without relaxing unrelated protection. Which qualification should the change record include?

  1. Enabling only an ARP inspection check may not validate every IP data packet's source identity.
  2. Increasing OSPF dead timers does not make incompatible authentication keys acceptable.
  3. Trusting all access ports would negate the primary protection against unauthorized DHCP servers.
  4. A role that appears read-only in one organization may still carry changes rights in another assigned scope.

Explanation

Correct Answer

D:

A role that appears read-only in one organization may still carry changes rights in another assigned scope. Intersight RBAC and organizational scoping define which managed resources an operator may control. Security engineering must restore the approved service without relaxing unrelated protection.

Incorrect Answers

A:

Enabling only an ARP inspection check may not validate every IP data packet's source identity. This concerns first-hop ip/mac spoof defense, not intersight scoped operations.

B:

Increasing OSPF dead timers does not make incompatible authentication keys acceptable. This concerns routing protocol keychain rollover, not intersight scoped operations.

C:

Trusting all access ports would negate the primary protection against unauthorized DHCP servers. This concerns DHCP snooping trusted uplink, not intersight scoped operations.

Question 411

A data-center VLAN loses its gateway whenever the active router is rebooted even though the standby has a working SVI. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which result would best confirm that the remediation worked?

  1. Receivers begin receiving the intended group traffic and multicast routing entries show the expected incoming interface.
  2. Hosts retain default-gateway reachability through a controlled active-router failure test.
  3. Remote MAC/IP routes appear in the EVPN database and tested inter-VTEP traffic succeeds.
  4. Approved templates match both peers, drift exceptions are resolved and service tests remain normal.

Explanation

Correct Answer

B:

Hosts retain default-gateway reachability through a controlled active-router failure test. This result tests the original failure rather than reporting merely that the configuration command was accepted. An FHRP keeps a virtual default gateway available while members transition between active and standby roles. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

Receivers begin receiving the intended group traffic and multicast routing entries show the expected incoming interface. This concerns PIM multicast rendezvous point, not first-hop gateway failover.

C:

Remote MAC/IP routes appear in the EVPN database and tested inter-VTEP traffic succeeds. This concerns mp-BGP evpn route learning, not first-hop gateway failover.

D:

Approved templates match both peers, drift exceptions are resolved and service tests remain normal. This concerns fabric configuration drift, not first-hop gateway failover.

Question 412

A blade's vNIC sees intermittent retransmissions after a QoS change, but ordinary UCS counters lack per-packet context. Operations is validating the host before approving production workload placement. Which test result best demonstrates restoration of the intended behavior?

  1. Hardware environmental faults are resolved and sustained compute tests no longer show thermal throttling.
  2. The server locates the approved boot target and starts consistently through planned reboots.
  3. A controlled capture identifies whether retransmissions coincide with drops or network reordering.
  4. The affected adapter fault clears after a supported fix and workload connectivity validates correctly.

Explanation

Correct Answer

C:

A controlled capture identifies whether retransmissions coincide with drops or network reordering. This result tests the original failure rather than reporting merely that the configuration command was accepted. Packet replication can reveal TCP and frame-level behavior that interface counters summarize only coarsely. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Hardware environmental faults are resolved and sustained compute tests no longer show thermal throttling. That response is associated with chassis power and thermal monitoring rather than the specific compute traffic span condition described here. For the stated failure, the preferred action is: Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path. Relevant evidence: Inspect capture-point support, vNIC policy, frame timestamps, queue counters and retransmission patterns. Operations is validating the host before approving production workload placement.

B:

The server locates the approved boot target and starts consistently through planned reboots. This concerns c-series boot policy alignment, not compute traffic span.

D:

The affected adapter fault clears after a supported fix and workload connectivity validates correctly. That response is associated with intersight alert triage rather than the specific compute traffic span condition described here. For the stated failure, the preferred action is: Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path. Relevant evidence: Inspect capture-point support, vNIC policy, frame timestamps, queue counters and retransmission patterns. Operations is validating the host before approving production workload placement.

Question 413

A replacement management cluster is being restored from an old UCS backup while recently issued MAC and WWPN pools may differ. Operations is validating the host before approving production workload placement. Why is the targeted engineering response justified in this situation?

  1. Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure.
  2. Physical power or cooling constraints can throttle compute even when guest metrics show no software error.
  3. Rolling hardware maintenance reduces service disruption only if dependent workloads can tolerate sequential host removal.
  4. A server and adapter firmware combination must be supported for its hardware and operating environment.

Explanation

Correct Answer

A:

Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure. Operations is validating the host before approving production workload placement.

Incorrect Answers

B:

Physical power or cooling constraints can throttle compute even when guest metrics show no software error. This concerns chassis power and thermal monitoring, not UCS restore integrity.

C:

Rolling hardware maintenance reduces service disruption only if dependent workloads can tolerate sequential host removal. This concerns UCS firmware change sequencing, not UCS restore integrity.

D:

A server and adapter firmware combination must be supported for its hardware and operating environment. This concerns UCS firmware compatibility, not UCS restore integrity.

Question 414

A fabric interconnect has never exported its current UCS configuration despite recent service-profile and policy changes. Operations is validating the host before approving production workload placement. What post-change observation gives the strongest evidence of success?

  1. An authorized operator can locate and validate the backup artifact and restore procedure in a controlled test.
  2. Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment.
  3. The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths.
  4. The intended traffic class meets its latency and drop requirements under a controlled mixed-load test.

Explanation

Correct Answer

A:

An authorized operator can locate and validate the backup artifact and restore procedure in a controlled test. This result tests the original failure rather than reporting merely that the configuration command was accepted. UCS configuration backups retain recovery information for policies and identities and should accompany approved changes. Operations is validating the host before approving production workload placement.

Incorrect Answers

B:

Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment. This concerns UCS mac pool uniqueness, not UCS management backup.

C:

The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths. This concerns SAN connectivity from blade chassis, not UCS management backup.

D:

The intended traffic class meets its latency and drop requirements under a controlled mixed-load test. This concerns UCS network qos policy, not UCS management backup.

Question 415

A Linux workload can reach an NFS server by IP but receives access denied when mounting its application share. A storage change board requires a traceable diagnosis before allowing further fabric changes. What should the operator avoid assuming from the observed state?

  1. Opening all export access to the entire subnet may bypass least privilege rather than fix the specific denial.
  2. Successful ICMP ping does not establish that iSCSI discovery or target authorization is working.
  3. Redundant supervisors do not make every FC software version transition nondisruptive.
  4. A green availability tile does not establish stable storage latency, fabric health or end-to-end redundancy.

Explanation

Correct Answer

A:

Opening all export access to the entire subnet may bypass least privilege rather than fix the specific denial. NFS file access is controlled by network and export permissions, not Fibre Channel zoning. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

B:

Successful ICMP ping does not establish that iSCSI discovery or target authorization is working. This concerns iscsi target discovery, not nfs export permissions.

C:

Redundant supervisors do not make every FC software version transition nondisruptive. This concerns mds nondisruptive upgrade planning, not nfs export permissions.

D:

A green availability tile does not establish stable storage latency, fabric health or end-to-end redundancy. This concerns nexus dashboard SAN monitoring, not nfs export permissions.

Question 416

A new Nexus switch starts Power On Auto Provisioning but stalls after DHCP because the boot image URL is unreachable. The automation change must pass a preproduction test and leave a verifiable audit trail. How should the implementation be validated against the original failure?

  1. The plan lists only intended devices and the deployment audit matches those targets without collateral changes.
  2. The utility reads the intended local input under the approved Guest Shell permissions and completes the task.
  3. The completed script retrieves the full authorized inventory across every page with no repeated identifiers.
  4. The device retrieves verified artifacts and applies the approved initial configuration successfully.

Explanation

Correct Answer

D:

The device retrieves verified artifacts and applies the approved initial configuration successfully. This result tests the original failure rather than reporting merely that the configuration command was accepted. POAP bootstrap depends on correct discovery and reachable provisioning artifacts, not DHCP completion alone. The automation change must pass a preproduction test and leave a verifiable audit trail.

Incorrect Answers

A:

The plan lists only intended devices and the deployment audit matches those targets without collateral changes. That response is associated with nexus dashboard automation scope rather than the specific poap bootstrap dependencies condition described here. For the stated failure, the preferred action is: Validate the DHCP options, image/script availability and bootstrap transport path before restarting POAP. Relevant evidence: Inspect DHCP offers, bootstrap URL, DNS/routing, file server availability and switch console logs. The automation change must pass a preproduction test and leave a verifiable audit trail.

B:

The utility reads the intended local input under the approved Guest Shell permissions and completes the task. This concerns guest shell isolation, not poap bootstrap dependencies.

C:

The completed script retrieves the full authorized inventory across every page with no repeated identifiers. That response is associated with python api pagination rather than the specific poap bootstrap dependencies condition described here. For the stated failure, the preferred action is: Validate the DHCP options, image/script availability and bootstrap transport path before restarting POAP. Relevant evidence: Inspect DHCP offers, bootstrap URL, DNS/routing, file server availability and switch console logs. The automation change must pass a preproduction test and leave a verifiable audit trail.

Question 417

A hypervisor installation leaves a virtual media image first in a UCS boot policy, causing repeated setup after power cycles. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which qualification should the change record include?

  1. Successful one-time installation does not ensure the persistent boot policy has been corrected.
  2. Changing the displayed server name does not resolve a duplicate effective network identifier.
  3. A template update must not be assumed to affect just the blade presently open in the UI.
  4. Manual association to an incompatible blade may bypass placement intent without satisfying hardware needs.

Explanation

Correct Answer

A:

Successful one-time installation does not ensure the persistent boot policy has been corrected. A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

B:

Changing the displayed server name does not resolve a duplicate effective network identifier. This concerns UCS mac pool uniqueness, not boot order and removable media.

C:

A template update must not be assumed to affect just the blade presently open in the UI. This concerns updating service-profile templates, not boot order and removable media.

D:

Manual association to an incompatible blade may bypass placement intent without satisfying hardware needs. This concerns server pool qualification, not boot order and removable media.

Question 418

A new Fibre Channel host is connected to an MDS switch but never receives a fabric identifier and cannot discover targets. A storage change board requires a traceable diagnosis before allowing further fabric changes. What caveat is critical when interpreting a successful remediation?

  1. Forcing suspended links into service without correcting compatibility can destabilize a SAN fabric.
  2. A redundant fabric cannot protect traffic that was incorrectly attached to a single SAN path.
  3. Renaming device aliases does not resolve an underlying Fibre Channel domain ID conflict.
  4. A target LUN mapping cannot repair a failed physical or fabric login on the initiator port.

Explanation

Correct Answer

D:

A target LUN mapping cannot repair a failed physical or fabric login on the initiator port. An initiator must complete fabric login and receive an FCID before normal fabric services can identify it. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Forcing suspended links into service without correcting compatibility can destabilize a SAN fabric. That response is associated with fibre channel port-channel consistency rather than the specific fibre channel fabric login condition described here. For the stated failure, the preferred action is: Validate physical FC link and initiator FLOGI registration before changing storage-array masking. Relevant evidence: Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events. A storage change board requires a traceable diagnosis before allowing further fabric changes.

B:

A redundant fabric cannot protect traffic that was incorrectly attached to a single SAN path. This concerns mds epld update impact, not fibre channel fabric login.

C:

Renaming device aliases does not resolve an underlying Fibre Channel domain ID conflict. That response is associated with fcid and domain id stability rather than the specific fibre channel fabric login condition described here. For the stated failure, the preferred action is: Validate physical FC link and initiator FLOGI registration before changing storage-array masking. Relevant evidence: Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Question 419

A storage administrator zones a host using a node name although the fabric login is registered with a different port identifier. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What should the operator avoid assuming from the observed state?

  1. A node-level WWNN cannot always replace a port-specific WWPN expected by the zoning policy.
  2. A storage-array firmware update is not a demonstrated cure for physical FC CRC errors.
  3. A link-up indicator for the parent trunk does not prove that every intended VSAN is carried.
  4. An ordinary Fibre Channel zone does not by itself create a separate control-plane fabric.

Explanation

Correct Answer

A:

A node-level WWNN cannot always replace a port-specific WWPN expected by the zoning policy. Fibre Channel port WWNs identify individual interfaces used by fabric login and zoning policies. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.

Incorrect Answers

B:

A storage-array firmware update is not a demonstrated cure for physical FC CRC errors. This concerns SAN port error telemetry, not wwpn versus wwnn.

C:

A link-up indicator for the parent trunk does not prove that every intended VSAN is carried. This concerns VSAN trunk mismatch, not wwpn versus wwnn.

D:

An ordinary Fibre Channel zone does not by itself create a separate control-plane fabric. This concerns VSAN isolation, not wwpn versus wwnn.

Question 420

Latency-sensitive storage traffic shares uplinks with a large backup flow and drops rise during congestion. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What is the best next implementation or troubleshooting step?

  1. Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs.
  2. Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks.
  3. Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment.
  4. Review UCS QoS classes and upstream priority handling across the entire network path.

Explanation

Correct Answer

D:

Review UCS QoS classes and upstream priority handling across the entire network path. QoS treatment is effective only when marking, queue allocation and congestion behavior align across involved devices. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs. This concerns UCS fabric redundancy, not UCS network qos policy.

B:

Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. This concerns SAN connectivity from blade chassis, not UCS network qos policy.

C:

Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment. This concerns UCS mac pool uniqueness, not UCS network qos policy.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.