Question 280
A blade has two configured vNICs, yet a failed fabric interconnect isolates all management and application traffic. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What is the best next implementation or troubleshooting step?
- Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities.
- Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs.
- Create and secure an appropriate management configuration backup before a major maintenance operation.
- Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path.
Explanation
Correct Answer
B:Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs. Logical dual vNIC definitions provide resilience only when each has a functioning independent physical fabric path. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.
Incorrect Answers
A:Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities. This concerns UCS blade chassis IOM discovery, not UCS fabric redundancy.
C:Create and secure an appropriate management configuration backup before a major maintenance operation. This concerns UCS management backup, not UCS fabric redundancy.
D:Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path. This concerns UCS VLAN pool and template, not UCS fabric redundancy.
Question 281
An engineer plans simultaneous firmware activation on every blade supporting a critical cluster with no evacuation plan. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Why is the targeted engineering response justified in this situation?
- A server and adapter firmware combination must be supported for its hardware and operating environment.
- Intersight resource assignment and RBAC limit which infrastructure objects and policies an administrator can manage.
- UCS-X in Intersight Managed Mode uses Intersight-defined policies and profiles rather than unmodified UCS Manager assumptions.
- Rolling hardware maintenance reduces service disruption only if dependent workloads can tolerate sequential host removal.
Explanation
Correct Answer
D:Rolling hardware maintenance reduces service disruption only if dependent workloads can tolerate sequential host removal. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.
Incorrect Answers
A:A server and adapter firmware combination must be supported for its hardware and operating environment. This concerns UCS firmware compatibility, not UCS firmware change sequencing.
B:Intersight resource assignment and RBAC limit which infrastructure objects and policies an administrator can manage. This concerns intersight organization scope, not UCS firmware change sequencing.
C:UCS-X in Intersight Managed Mode uses Intersight-defined policies and profiles rather than unmodified UCS Manager assumptions. This concerns UCS-x intersight managed mode, not UCS firmware change sequencing.
Question 282
A SAN change places multiple unrelated hosts and several targets in one broad Fibre Channel zone to simplify access. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What should the engineer do first to address the observed failure?
- Activate the intended zoneset on the correct VSAN and validate its active membership.
- Check the CFS distribution scope and commit or activation workflow for the affected feature.
- Apply a least-privilege zoning design with an individual initiator and explicitly approved target members per zone.
- Reconcile FCNS registrations and target identity changes before recreating the entire VSAN.
Explanation
Correct Answer
C:Apply a least-privilege zoning design with an individual initiator and explicitly approved target members per zone. Tightly scoped FC zones limit which initiators can discover or communicate with designated targets. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.
Incorrect Answers
A:Activate the intended zoneset on the correct VSAN and validate its active membership. This concerns zoneset activation state, not single-initiator zoning.
B:Check the CFS distribution scope and commit or activation workflow for the affected feature. This concerns cisco fabric services distribution, not single-initiator zoning.
D:Reconcile FCNS registrations and target identity changes before recreating the entire VSAN. This concerns fibre channel name-server entries, not single-initiator zoning.
Question 283
Receivers on a routed multicast fabric join a group, but sources in another subnet do not reach them after an RP address change. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What information should be inspected before the change is applied?
- Inspect peer-link state, peer-keepalive reachability, consistency checks and suspended port reasons.
- Inspect HSRP or VRRP group IDs, virtual IPs, priorities, tracking and peer status.
- Inspect EVPN BGP neighbor state, advertised Type-2 routes, route targets and the corresponding VNI.
- Inspect PIM neighbors, RP mapping, join state and reverse-path-forwarding interfaces.
Explanation
Correct Answer
D:Inspect PIM neighbors, RP mapping, join state and reverse-path-forwarding interfaces. These records help distinguish the suspected failure from a superficially similar fault before modifying production. PIM sparse mode relies on correct multicast routing state and, where applicable, an RP for shared-tree discovery. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.
Incorrect Answers
A:Inspect peer-link state, peer-keepalive reachability, consistency checks and suspended port reasons. This concerns vpc peer-link recovery, not PIM multicast rendezvous point.
B:Inspect HSRP or VRRP group IDs, virtual IPs, priorities, tracking and peer status. This concerns first-hop gateway failover, not PIM multicast rendezvous point.
C:Inspect EVPN BGP neighbor state, advertised Type-2 routes, route targets and the corresponding VNI. This concerns mp-BGP evpn route learning, not PIM multicast rendezvous point.
Question 284
A SAN-boot blade fails to discover the primary boot LUN even though the fibre channel interface shows link up. Operations is validating the host before approving production workload placement. Which limitation prevents the team from overgeneralizing this result?
- An FC link up indication alone cannot prove that the boot LUN is authorized and reachable.
- Manual association to an incompatible blade may bypass placement intent without satisfying hardware needs.
- A unique server serial number does not replace unique Fibre Channel initiator identifiers.
- Changing a SAN zone alone will not override a boot order still set to local media.
Explanation
Correct Answer
A:An FC link up indication alone cannot prove that the boot LUN is authorized and reachable. SAN boot requires all of the initiator, fabric zoning, target presentation and boot policy to agree. Operations is validating the host before approving production workload placement.
Incorrect Answers
B:Manual association to an incompatible blade may bypass placement intent without satisfying hardware needs. That response is associated with server pool qualification rather than the specific san boot path policy condition described here. For the stated failure, the preferred action is: Validate the service-profile SAN boot target WWPN/LUN settings and underlying zoning/masking path. Relevant evidence: Inspect service-profile boot targets, FLOGI, active zones, array masking and target LUN visibility. Operations is validating the host before approving production workload placement.
C:A unique server serial number does not replace unique Fibre Channel initiator identifiers. That response is associated with wwpn pool allocation rather than the specific san boot path policy condition described here. For the stated failure, the preferred action is: Validate the service-profile SAN boot target WWPN/LUN settings and underlying zoning/masking path. Relevant evidence: Inspect service-profile boot targets, FLOGI, active zones, array masking and target LUN visibility. Operations is validating the host before approving production workload placement.
D:Changing a SAN zone alone will not override a boot order still set to local media. This concerns c-series boot policy alignment, not SAN boot path policy.
Question 285
A maintenance script needs to run on a fixed schedule but an engineer proposes an EEM syslog trigger instead. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. Which technical principle best explains the recommended response?
- Guest Shell provides a separate Linux execution environment with its own file and permission context.
- Scheduled tasks follow time-based execution rather than requiring a spontaneous syslog event to fire.
- Declarative, state-aware automation should converge on the desired configuration without producing repeated unnecessary changes.
- Embedded Event Manager runs configured actions in response to matching local events and authorization constraints.
Explanation
Correct Answer
B:Scheduled tasks follow time-based execution rather than requiring a spontaneous syslog event to fire. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.
Incorrect Answers
A:Guest Shell provides a separate Linux execution environment with its own file and permission context. This concerns guest shell isolation, not nx-os scheduler jobs.
C:Declarative, state-aware automation should converge on the desired configuration without producing repeated unnecessary changes. This concerns ansible idempotent templates, not nx-os scheduler jobs.
D:Embedded Event Manager runs configured actions in response to matching local events and authorization constraints. This concerns eem syslog-triggered remediation, not nx-os scheduler jobs.
Question 286
An operations team sees sporadic storage-path instability but its monitoring only polls device availability every five minutes. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What should the engineer do first to address the observed failure?
- Activate the intended zoneset on the correct VSAN and validate its active membership.
- Correlate SAN-specific health and interface telemetry in supported Nexus Dashboard or MDS monitoring tools.
- Check the CFS distribution scope and commit or activation workflow for the affected feature.
- Apply a least-privilege zoning design with an individual initiator and explicitly approved target members per zone.
Explanation
Correct Answer
B:Correlate SAN-specific health and interface telemetry in supported Nexus Dashboard or MDS monitoring tools. Topology, fabric events and time-series indicators reveal path problems hidden by simple reachability polling. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.
Incorrect Answers
A:Activate the intended zoneset on the correct VSAN and validate its active membership. This concerns zoneset activation state, not nexus dashboard SAN monitoring.
C:Check the CFS distribution scope and commit or activation workflow for the affected feature. This concerns cisco fabric services distribution, not nexus dashboard SAN monitoring.
D:Apply a least-privilege zoning design with an individual initiator and explicitly approved target members per zone. This concerns single-initiator zoning, not nexus dashboard SAN monitoring.
Question 287
A SAN array replaces a target HBA but operators try to keep its old WWPN hidden behind the same device alias without verification. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. Which controlled change is most appropriate given the evidence?
- Reconcile FCNS registrations and target identity changes before recreating the entire VSAN.
- Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning.
- Update the device alias to the authorized new WWPN and validate all zoning references before applying it.
- Verify iSCSI discovery addresses, initiator identity, authentication and storage VLAN path.
Explanation
Correct Answer
C:Update the device alias to the authorized new WWPN and validate all zoning references before applying it. Device aliases map readable names to FC identifiers and must follow actual hardware identity changes. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.
Incorrect Answers
A:Reconcile FCNS registrations and target identity changes before recreating the entire VSAN. This concerns fibre channel name-server entries, not device alias maintenance.
B:Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. This concerns npv uplink fabric services, not device alias maintenance.
D:Verify iSCSI discovery addresses, initiator identity, authentication and storage VLAN path. This concerns iscsi target discovery, not device alias maintenance.
Question 288
Clients connected to an access switch stop receiving DHCP leases after DHCP snooping is enabled. Security engineering must restore the approved service without relaxing unrelated protection. Which result would best confirm that the remediation worked?
- Authorized static hosts pass ARP inspection while forged bindings remain blocked.
- Clients obtain leases from the authorized server and rogue DHCP replies on access ports are still rejected.
- Tagged VMs appear in the intended microsegmented EPG and only approved flows traverse the boundary.
- Spoofed source addresses are dropped while approved host traffic continues normally.
Explanation
Correct Answer
B:Clients obtain leases from the authorized server and rogue DHCP replies on access ports are still rejected. This result tests the original failure rather than reporting merely that the configuration command was accepted. DHCP snooping should accept DHCP server responses from trusted paths while suppressing rogue access-port servers. Security engineering must restore the approved service without relaxing unrelated protection.
Incorrect Answers
A:Authorized static hosts pass ARP inspection while forged bindings remain blocked. That response is associated with dynamic arp inspection source of truth rather than the specific dhcp snooping trusted uplink condition described here. For the stated failure, the preferred action is: Mark only the verified DHCP-server-facing interface as trusted and validate the snooping VLAN scope. Relevant evidence: Inspect DHCP snooping trust configuration, VLAN enrollment, packet drops and server uplink topology. Security engineering must restore the approved service without relaxing unrelated protection.
C:Tagged VMs appear in the intended microsegmented EPG and only approved flows traverse the boundary. This concerns aci microsegmentation selector, not DHCP snooping trusted uplink.
D:Spoofed source addresses are dropped while approved host traffic continues normally. That response is associated with first-hop ip/mac spoof defense rather than the specific dhcp snooping trusted uplink condition described here. For the stated failure, the preferred action is: Mark only the verified DHCP-server-facing interface as trusted and validate the snooping VLAN scope. Relevant evidence: Inspect DHCP snooping trust configuration, VLAN enrollment, packet drops and server uplink topology. Security engineering must restore the approved service without relaxing unrelated protection.
Question 289
An infrastructure engineer changes a Nexus policy directly in production and an upcoming Terraform apply attempts to revert it unexpectedly. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. What is the strongest technical basis for the recommended action?
- Guest Shell provides a separate Linux execution environment with its own file and permission context.
- Intersight objects and their assignments must satisfy resource visibility and scope permissions.
- Credential protection and least privilege reduce the impact of source-code disclosure.
- Terraform compares declared infrastructure with observed resources and can undo unmanaged changes during apply.
Explanation
Correct Answer
D:Terraform compares declared infrastructure with observed resources and can undo unmanaged changes during apply. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.
Incorrect Answers
A:Guest Shell provides a separate Linux execution environment with its own file and permission context. This concerns guest shell isolation, not terraform plan and state.
B:Intersight objects and their assignments must satisfy resource visibility and scope permissions. This concerns intersight policy automation, not terraform plan and state.
C:Credential protection and least privilege reduce the impact of source-code disclosure. This concerns powershell api token security, not terraform plan and state.
Question 290
Two application teams use the same physical SAN switches but must keep their fabric control traffic separated. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which result would best confirm that the remediation worked?
- The active zoneset contains the actual registered port WWPNs and the host discovers its target.
- Each team's initiators and targets register only within the approved VSAN and access boundaries.
- Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets.
- The alias resolves to the correct active target identity and the host's allowed storage paths work.
Explanation
Correct Answer
B:Each team's initiators and targets register only within the approved VSAN and access boundaries. This result tests the original failure rather than reporting merely that the configuration command was accepted. VSANs provide logical fabric separation across shared physical Fibre Channel infrastructure. A storage change board requires a traceable diagnosis before allowing further fabric changes.
Incorrect Answers
A:The active zoneset contains the actual registered port WWPNs and the host discovers its target. That response is associated with wwpn versus wwnn rather than the specific vsan isolation condition described here. For the stated failure, the preferred action is: Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. Relevant evidence: Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. A storage change board requires a traceable diagnosis before allowing further fabric changes.
C:Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets. That response is associated with npv uplink fabric services rather than the specific vsan isolation condition described here. For the stated failure, the preferred action is: Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. Relevant evidence: Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. A storage change board requires a traceable diagnosis before allowing further fabric changes.
D:The alias resolves to the correct active target identity and the host's allowed storage paths work. This concerns device alias maintenance, not VSAN isolation.
Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests