Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 30

Question 290

Two application teams use the same physical SAN switches but must keep their fabric control traffic separated. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which result would best confirm that the remediation worked?

  1. The active zoneset contains the actual registered port WWPNs and the host discovers its target.
  2. Each team's initiators and targets register only within the approved VSAN and access boundaries.
  3. Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets.
  4. The alias resolves to the correct active target identity and the host's allowed storage paths work.

Explanation

Correct Answer

B:

Each team's initiators and targets register only within the approved VSAN and access boundaries. This result tests the original failure rather than reporting merely that the configuration command was accepted. VSANs provide logical fabric separation across shared physical Fibre Channel infrastructure. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

The active zoneset contains the actual registered port WWPNs and the host discovers its target. That response is associated with wwpn versus wwnn rather than the specific vsan isolation condition described here. For the stated failure, the preferred action is: Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. Relevant evidence: Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

C:

Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets. That response is associated with npv uplink fabric services rather than the specific vsan isolation condition described here. For the stated failure, the preferred action is: Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. Relevant evidence: Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

D:

The alias resolves to the correct active target identity and the host's allowed storage paths work. This concerns device alias maintenance, not VSAN isolation.

Question 291

An unauthorized initiator plugs into an available SAN switch port and attempts fabric login using an unapproved WWPN. A follow-up access review asks the team to validate the same boundary with a controlled negative test. Which controlled change is most appropriate given the evidence?

  1. Replace the inherited privilege with a least-privilege SAN read/monitor role and confirm AAA enforcement.
  2. Configure and test the approved AAA method order and protected break-glass account following change policy.
  3. Configure approved Fibre Channel port-security bindings and verify rejection of unregistered identities.
  4. Enforce an approved fabric-binding policy for permitted switch identities and review authorized ISL membership.

Explanation

Correct Answer

C:

Configure approved Fibre Channel port-security bindings and verify rejection of unregistered identities. FC port security can restrict which device WWNs are permitted to connect through designated fabric ports. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

A:

Replace the inherited privilege with a least-privilege SAN read/monitor role and confirm AAA enforcement. This concerns mds SAN administrative control, not fibre channel port security.

B:

Configure and test the approved AAA method order and protected break-glass account following change policy. This concerns centralized AAA fallback, not fibre channel port security.

D:

Enforce an approved fabric-binding policy for permitted switch identities and review authorized ISL membership. This concerns fabric binding membership, not fibre channel port security.

Question 292

An NX-OS switch logs an uplink failure but an EEM policy intended to notify the NOC never triggers. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. What is the strongest technical basis for the recommended action?

  1. An HTTP 403 indicates a reachable endpoint has refused the request under its authorization controls.
  2. Guest Shell provides a separate Linux execution environment with its own file and permission context.
  3. Embedded Event Manager runs configured actions in response to matching local events and authorization constraints.
  4. Scheduled tasks follow time-based execution rather than requiring a spontaneous syslog event to fire.

Explanation

Correct Answer

C:

Embedded Event Manager runs configured actions in response to matching local events and authorization constraints. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.

Incorrect Answers

A:

An HTTP 403 indicates a reachable endpoint has refused the request under its authorization controls. This concerns nx-api request authorization, not eem syslog-triggered remediation.

B:

Guest Shell provides a separate Linux execution environment with its own file and permission context. This concerns guest shell isolation, not eem syslog-triggered remediation.

D:

Scheduled tasks follow time-based execution rather than requiring a spontaneous syslog event to fire. This concerns nx-os scheduler jobs, not eem syslog-triggered remediation.

Question 293

A UCS blade shows unexplained throttling during compute peaks despite normal guest operating-system logs. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which technical principle best explains the recommended response?

  1. The blade chassis depends on a healthy IOM and fabric-interconnect management path to discover and service blades.
  2. Packet replication can reveal TCP and frame-level behavior that interface counters summarize only coarsely.
  3. Hardware alerts require component-level evidence; unrelated performance alarms may have a separate root cause.
  4. Physical power or cooling constraints can throttle compute even when guest metrics show no software error.

Explanation

Correct Answer

D:

Physical power or cooling constraints can throttle compute even when guest metrics show no software error. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

The blade chassis depends on a healthy IOM and fabric-interconnect management path to discover and service blades. This concerns UCS blade chassis IOM discovery, not chassis power and thermal monitoring.

B:

Packet replication can reveal TCP and frame-level behavior that interface counters summarize only coarsely. This concerns compute traffic span, not chassis power and thermal monitoring.

C:

Hardware alerts require component-level evidence; unrelated performance alarms may have a separate root cause. This concerns intersight alert triage, not chassis power and thermal monitoring.

Question 294

A new Nexus switch starts Power On Auto Provisioning but stalls after DHCP because the boot image URL is unreachable. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. What should the engineer collect before ruling out other causes?

  1. Inspect response metadata, page limits, next tokens, error responses and known inventory counts.
  2. Inspect EEM detector configuration, actual syslog message, applet history and action permissions.
  3. Inspect target site IDs, inventory assignments, proposed diffs and authorizations.
  4. Inspect DHCP offers, bootstrap URL, DNS/routing, file server availability and switch console logs.

Explanation

Correct Answer

D:

Inspect DHCP offers, bootstrap URL, DNS/routing, file server availability and switch console logs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. POAP bootstrap depends on correct discovery and reachable provisioning artifacts, not DHCP completion alone. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.

Incorrect Answers

A:

Inspect response metadata, page limits, next tokens, error responses and known inventory counts. This concerns python api pagination, not poap bootstrap dependencies.

B:

Inspect EEM detector configuration, actual syslog message, applet history and action permissions. This concerns eem syslog-triggered remediation, not poap bootstrap dependencies.

C:

Inspect target site IDs, inventory assignments, proposed diffs and authorizations. This concerns nexus dashboard automation scope, not poap bootstrap dependencies.

Question 295

An Intersight user has authorization to restart one lab server but can also deploy profiles to production organizations. A follow-up access review asks the team to validate the same boundary with a controlled negative test. Which intervention most directly addresses the stated condition?

  1. Assign a scoped UCS administrative role that permits health visibility without SAN policy modification.
  2. Limit the user to the appropriate organization, resource group and role for the lab estate.
  3. Replace the inherited privilege with a least-privilege SAN read/monitor role and confirm AAA enforcement.
  4. Enable and validate supported MACsec on both compatible link endpoints with an approved keying design.

Explanation

Correct Answer

B:

Limit the user to the appropriate organization, resource group and role for the lab estate. Intersight RBAC and organizational scoping define which managed resources an operator may control. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

A:

Assign a scoped UCS administrative role that permits health visibility without SAN policy modification. This concerns UCS administrative separation, not intersight scoped operations.

C:

Replace the inherited privilege with a least-privilege SAN read/monitor role and confirm AAA enforcement. This concerns mds SAN administrative control, not intersight scoped operations.

D:

Enable and validate supported MACsec on both compatible link endpoints with an approved keying design. This concerns MACsec protection scope, not intersight scoped operations.

Question 296

A SAN supervisor EPLD change is scheduled during peak transaction load without assessing module reload requirements. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which test result best demonstrates restoration of the intended behavior?

  1. Error counters stop increasing after the physical fix and application storage latency improves.
  2. Post-update EPLD versions are correct and tested host multipath failover retains service during planned disruption.
  3. The approved client mounts the correct export with intended read/write access and no overbroad client allowance.
  4. The authorized initiator establishes the intended iSCSI sessions and sees the mapped LUN through supported paths.

Explanation

Correct Answer

B:

Post-update EPLD versions are correct and tested host multipath failover retains service during planned disruption. This result tests the original failure rather than reporting merely that the configuration command was accepted. An EPLD update may reset affected SAN hardware even if a previous NX-OS patch required no outage. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Error counters stop increasing after the physical fix and application storage latency improves. This concerns SAN port error telemetry, not mds epld update impact.

C:

The approved client mounts the correct export with intended read/write access and no overbroad client allowance. This concerns nfs export permissions, not mds epld update impact.

D:

The authorized initiator establishes the intended iSCSI sessions and sees the mapped LUN through supported paths. This concerns iscsi target discovery, not mds epld update impact.

Question 297

An administrator imports a service-profile template and two new server identities unexpectedly request an overlapping MAC range. Operations is validating the host before approving production workload placement. How should the implementation be validated against the original failure?

  1. An authorized operator can locate and validate the backup artifact and restore procedure in a controlled test.
  2. The intended traffic class meets its latency and drop requirements under a controlled mixed-load test.
  3. The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface.
  4. Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment.

Explanation

Correct Answer

D:

Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment. This result tests the original failure rather than reporting merely that the configuration command was accepted. UCS identity pools must avoid reuse because overlapping MAC addresses can cause Layer 2 instability and confusing endpoint learning. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

An authorized operator can locate and validate the backup artifact and restore procedure in a controlled test. This concerns UCS management backup, not UCS mac pool uniqueness.

B:

The intended traffic class meets its latency and drop requirements under a controlled mixed-load test. That response is associated with ucs network qos policy rather than the specific ucs mac pool uniqueness condition described here. For the stated failure, the preferred action is: Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment. Relevant evidence: Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables. Operations is validating the host before approving production workload placement.

C:

The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface. That response is associated with ucs vlan pool and template rather than the specific ucs mac pool uniqueness condition described here. For the stated failure, the preferred action is: Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment. Relevant evidence: Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables. Operations is validating the host before approving production workload placement.

Question 298

A blade's vHBA is configured but the upstream SAN fabric never sees its WWPN login. Operations is validating the host before approving production workload placement. Which evidence set most directly tests the suspected failure?

  1. Inspect WWPN pool reservations, active vHBA identities, fabric login records and zoning references.
  2. Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries.
  3. Inspect vNIC QoS policies, DCB settings if applicable, interface queue drops and upstream class maps.
  4. Inspect cluster failover capacity, target firmware policy, activation impact and host migration status.

Explanation

Correct Answer

B:

Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries. These records help distinguish the suspected failure from a superficially similar fault before modifying production. A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Inspect WWPN pool reservations, active vHBA identities, fabric login records and zoning references. That response is associated with wwpn pool allocation rather than the specific san connectivity from blade chassis condition described here. For the stated failure, the preferred action is: Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. Relevant evidence: Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries. Operations is validating the host before approving production workload placement.

C:

Inspect vNIC QoS policies, DCB settings if applicable, interface queue drops and upstream class maps. That response is associated with ucs network qos policy rather than the specific san connectivity from blade chassis condition described here. For the stated failure, the preferred action is: Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. Relevant evidence: Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries. Operations is validating the host before approving production workload placement.

D:

Inspect cluster failover capacity, target firmware policy, activation impact and host migration status. This concerns UCS firmware change sequencing, not SAN connectivity from blade chassis.

Question 299

An operator plans an EPLD firmware update during a business peak because a software patch earlier completed without traffic loss. The team is preparing a controlled production change and must preserve fabric reachability. What should the operator avoid assuming from the observed state?

  1. Changing a BGP route map cannot repair a mismatched OSPF adjacency at this hop.
  2. A working keepalive is not a replacement data path for the vPC peer-link.
  3. Past nondisruptive NX-OS upgrades do not establish EPLD update impact on this hardware.
  4. An overall green dashboard health score does not guarantee all application paths perform normally.

Explanation

Correct Answer

C:

Past nondisruptive NX-OS upgrades do not establish EPLD update impact on this hardware. Programmable-logic updates can require component reset or reload even when an unrelated software patch did not. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Changing a BGP route map cannot repair a mismatched OSPF adjacency at this hop. This concerns OSPF area compatibility, not epld firmware maintenance.

B:

A working keepalive is not a replacement data path for the vPC peer-link. This concerns vpc peer-link recovery, not epld firmware maintenance.

D:

An overall green dashboard health score does not guarantee all application paths perform normally. This concerns nexus dashboard fabric visibility, not epld firmware maintenance.

Question 300

An automated UCS association binds a high-memory workload to a blade that lacks the required adapter capability. Operations is validating the host before approving production workload placement. Which test result best demonstrates restoration of the intended behavior?

  1. The workload profile attaches only to blades meeting the declared capacity and adapter criteria.
  2. The chassis and blades enroll in the correct domain and receive valid Intersight-managed profiles.
  3. The blade discovers the intended boot LUN and boots after a controlled restart.
  4. Only the approved profile scope receives the tested update, with unrelated services preserved.

Explanation

Correct Answer

A:

The workload profile attaches only to blades meeting the declared capacity and adapter criteria. This result tests the original failure rather than reporting merely that the configuration command was accepted. Pool qualification policies can restrict association based on compatible server hardware characteristics. Operations is validating the host before approving production workload placement.

Incorrect Answers

B:

The chassis and blades enroll in the correct domain and receive valid Intersight-managed profiles. This concerns UCS-x intersight managed mode, not server pool qualification.

C:

The blade discovers the intended boot LUN and boots after a controlled restart. That response is associated with san boot path policy rather than the specific server pool qualification condition described here. For the stated failure, the preferred action is: Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies. Relevant evidence: Inspect server inventory, qualification criteria, pool membership and association failures. Operations is validating the host before approving production workload placement.

D:

Only the approved profile scope receives the tested update, with unrelated services preserved. That response is associated with updating service-profile templates rather than the specific server pool qualification condition described here. For the stated failure, the preferred action is: Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies. Relevant evidence: Inspect server inventory, qualification criteria, pool membership and association failures. Operations is validating the host before approving production workload placement.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.