Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 28

Question 270

A new VXLAN leaf advertises local VNIs but tunnels to another leaf fail because the VTEP source loopback is missing from underlay routing. The team is preparing a controlled production change and must preserve fabric reachability. Which explanation most directly accounts for the required correction?

  1. Model-driven telemetry can provide pushed state updates more frequently than coarse periodic polling.
  2. VXLAN encapsulation depends on routable IP transport between VTEP endpoints before tenant traffic can traverse it.
  3. Unknown-unicast, broadcast and multicast frames require an appropriate VXLAN replication or multicast transport method.
  4. An FHRP keeps a virtual default gateway available while members transition between active and standby roles.

Explanation

Correct Answer

B:

VXLAN encapsulation depends on routable IP transport between VTEP endpoints before tenant traffic can traverse it. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Model-driven telemetry can provide pushed state updates more frequently than coarse periodic polling. This concerns streaming telemetry health, not vxlan vtep underlay reachability.

C:

Unknown-unicast, broadcast and multicast frames require an appropriate VXLAN replication or multicast transport method. This concerns bum replication behavior, not vxlan vtep underlay reachability.

D:

An FHRP keeps a virtual default gateway available while members transition between active and standby roles. This concerns first-hop gateway failover, not vxlan vtep underlay reachability.

Question 271

After a hypervisor migration, ACI virtual machine endpoints do not appear in the intended EPG although the VLAN already exists in the fabric. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which intervention most directly addresses the stated condition?

  1. Validate fabric discovery prerequisites, physical connectivity and node registration in APIC.
  2. Verify the VLAN pool, domain, AEP and interface policy group associations serving the endpoint port.
  3. Reconcile the VMM domain association, hypervisor inventory and EPG port-group mapping.
  4. Advertise and verify the VTEP source-loopback reachability in the underlay routing domain.

Explanation

Correct Answer

C:

Reconcile the VMM domain association, hypervisor inventory and EPG port-group mapping. ACI VMM integration maps VM networks and EPGs through the virtualized domain to appropriate fabric policy. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

Validate fabric discovery prerequisites, physical connectivity and node registration in APIC. This concerns aci fabric discovery, not aci vmm association.

B:

Verify the VLAN pool, domain, AEP and interface policy group associations serving the endpoint port. This concerns aci access policy chain, not aci vmm association.

D:

Advertise and verify the VTEP source-loopback reachability in the underlay routing domain. This concerns vxlan vtep underlay reachability, not aci vmm association.

Question 272

A four-link server port-channel forwards on two members because the other members use incompatible trunk settings. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What caveat is critical when interpreting a successful remediation?

  1. Adding an EVPN route target cannot overcome a missing underlay IP path to the remote VTEP.
  2. A working keepalive is not a replacement data path for the vPC peer-link.
  3. LACP negotiation cannot compensate for incompatible allowed VLAN or switching-mode settings.
  4. Forcing every redundant port to forward would create a bridging loop rather than improve resilience.

Explanation

Correct Answer

C:

LACP negotiation cannot compensate for incompatible allowed VLAN or switching-mode settings. LACP aggregates only compatible interfaces, and inconsistent operational settings can suspend members. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

Adding an EVPN route target cannot overcome a missing underlay IP path to the remote VTEP. This concerns vxlan vtep underlay reachability, not lacp member mismatch.

B:

A working keepalive is not a replacement data path for the vPC peer-link. This concerns vpc peer-link recovery, not lacp member mismatch.

D:

Forcing every redundant port to forward would create a bridging loop rather than improve resilience. This concerns rstp blocked uplink, not lacp member mismatch.

Question 273

An orchestration service retries a configuration POST after timeout and produces duplicate resources on a Nexus management controller. The automation change must pass a preproduction test and leave a verifiable audit trail. Which test result best demonstrates restoration of the intended behavior?

  1. A simulated timeout followed by retry yields one intended resource and a documented final state.
  2. The authorized client runs the intended read-only API call and receives the expected structured result.
  3. The utility reads the intended local input under the approved Guest Shell permissions and completes the task.
  4. Tests with absent fields return an explicit unknown/error outcome rather than a fabricated healthy metric.

Explanation

Correct Answer

A:

A simulated timeout followed by retry yields one intended resource and a documented final state. This result tests the original failure rather than reporting merely that the configuration command was accepted. Retrying non-idempotent create operations without state checks can duplicate resources after ambiguous timeouts. The automation change must pass a preproduction test and leave a verifiable audit trail.

Incorrect Answers

B:

The authorized client runs the intended read-only API call and receives the expected structured result. That response is associated with nx-api request authorization rather than the specific rest api retries and idempotence condition described here. For the stated failure, the preferred action is: Check API operation semantics and implement safe read-before-create or idempotent reconciliation behavior. Relevant evidence: Inspect API logs, resource identifiers, HTTP response history and current running object state. The automation change must pass a preproduction test and leave a verifiable audit trail.

C:

The utility reads the intended local input under the approved Guest Shell permissions and completes the task. This concerns guest shell isolation, not rest api retries and idempotence.

D:

Tests with absent fields return an explicit unknown/error outcome rather than a fabricated healthy metric. That response is associated with on-box python exception handling rather than the specific rest api retries and idempotence condition described here. For the stated failure, the preferred action is: Check API operation semantics and implement safe read-before-create or idempotent reconciliation behavior. Relevant evidence: Inspect API logs, resource identifiers, HTTP response history and current running object state. The automation change must pass a preproduction test and leave a verifiable audit trail.

Question 274

A replacement management cluster is being restored from an old UCS backup while recently issued MAC and WWPN pools may differ. Operations is validating the host before approving production workload placement. Which observations would best validate the initial diagnosis?

  1. Inspect backup timestamp, pool assignments, profile associations and supported restore-mode prerequisites.
  2. Inspect domain claim, domain profile bindings, uplink policies and deployment events.
  3. Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding.
  4. Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs.

Explanation

Correct Answer

A:

Inspect backup timestamp, pool assignments, profile associations and supported restore-mode prerequisites. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure. Operations is validating the host before approving production workload placement.

Incorrect Answers

B:

Inspect domain claim, domain profile bindings, uplink policies and deployment events. This concerns intersight domain profile, not UCS restore integrity.

C:

Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding. This concerns UCS fabric redundancy, not UCS restore integrity.

D:

Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs. This concerns UCS blade chassis IOM discovery, not UCS restore integrity.

Question 275

A C-Series host repeatedly boots local media even though its approved UCS policy specifies a SAN boot target. Operations is validating the host before approving production workload placement. Which result would best confirm that the remediation worked?

  1. Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct.
  2. The intended traffic class meets its latency and drop requirements under a controlled mixed-load test.
  3. The server locates the approved boot target and starts consistently through planned reboots.
  4. The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths.

Explanation

Correct Answer

C:

The server locates the approved boot target and starts consistently through planned reboots. This result tests the original failure rather than reporting merely that the configuration command was accepted. The effective boot order and accessible target devices determine which source a Cisco server attempts during initialization. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct. This concerns wwpn pool allocation, not c-series boot policy alignment.

B:

The intended traffic class meets its latency and drop requirements under a controlled mixed-load test. This concerns UCS network qos policy, not c-series boot policy alignment.

D:

The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths. This concerns SAN connectivity from blade chassis, not c-series boot policy alignment.

Question 276

A new C-Series rack server powers on but its management controller cannot be reached from the secure operations subnet. Operations is validating the host before approving production workload placement. Which test result best demonstrates restoration of the intended behavior?

  1. The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface.
  2. The management controller responds from the authorized subnet and administrator login is audited.
  3. Traffic remains available across a controlled single-fabric interruption with expected failover behavior.
  4. Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment.

Explanation

Correct Answer

B:

The management controller responds from the authorized subnet and administrator login is audited. This result tests the original failure rather than reporting merely that the configuration command was accepted. The CIMC out-of-band interface requires correctly configured management connectivity independent of the installed server operating system. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface. This concerns UCS VLAN pool and template, not UCS c-series cimc reachability.

C:

Traffic remains available across a controlled single-fabric interruption with expected failover behavior. This concerns UCS fabric redundancy, not UCS c-series cimc reachability.

D:

Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment. This concerns UCS mac pool uniqueness, not UCS c-series cimc reachability.

Question 277

A Linux workload can reach an NFS server by IP but receives access denied when mounting its application share. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which controlled change is most appropriate given the evidence?

  1. Check the CFS distribution scope and commit or activation workflow for the affected feature.
  2. Validate NFS export authorization, client identity and supported protocol settings before altering the SAN fabric.
  3. Investigate Fibre Channel domain ID assignments and fabric merge requirements before allowing the ISL to join.
  4. Apply a least-privilege zoning design with an individual initiator and explicitly approved target members per zone.

Explanation

Correct Answer

B:

Validate NFS export authorization, client identity and supported protocol settings before altering the SAN fabric. NFS file access is controlled by network and export permissions, not Fibre Channel zoning. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Check the CFS distribution scope and commit or activation workflow for the affected feature. This concerns cisco fabric services distribution, not nfs export permissions.

C:

Investigate Fibre Channel domain ID assignments and fabric merge requirements before allowing the ISL to join. This concerns fcid and domain id stability, not nfs export permissions.

D:

Apply a least-privilege zoning design with an individual initiator and explicitly approved target members per zone. This concerns single-initiator zoning, not nfs export permissions.

Question 278

After staging a server firmware upgrade, the adapter and BIOS target versions differ from the supported hardware compatibility matrix. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which controlled change is most appropriate given the evidence?

  1. Validate the service-profile SAN boot target WWPN/LUN settings and underlying zoning/masking path.
  2. Reconcile firmware targets with the Cisco-supported hardware and software compatibility guidance before activation.
  3. Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies.
  4. Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities.

Explanation

Correct Answer

B:

Reconcile firmware targets with the Cisco-supported hardware and software compatibility guidance before activation. A server and adapter firmware combination must be supported for its hardware and operating environment. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Validate the service-profile SAN boot target WWPN/LUN settings and underlying zoning/masking path. This concerns SAN boot path policy, not UCS firmware compatibility.

C:

Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies. This concerns server pool qualification, not UCS firmware compatibility.

D:

Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities. This concerns wwpn pool allocation, not UCS firmware compatibility.

Question 279

An MDS operator edits the configured zoneset but a host still cannot discover the newly authorized storage target. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What is the strongest technical basis for the recommended action?

  1. SAN nondisruptive upgrade support depends on exact software path, hardware redundancy and active feature constraints.
  2. The fabric name server reflects registered port identities and can reveal whether the expected target is visible.
  3. Configured zones and active enforced zoning can differ until the appropriate zoneset is activated.
  4. Tightly scoped FC zones limit which initiators can discover or communicate with designated targets.

Explanation

Correct Answer

C:

Configured zones and active enforced zoning can differ until the appropriate zoneset is activated. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.

Incorrect Answers

A:

SAN nondisruptive upgrade support depends on exact software path, hardware redundancy and active feature constraints. This concerns mds nondisruptive upgrade planning, not zoneset activation state.

B:

The fabric name server reflects registered port identities and can reveal whether the expected target is visible. This concerns fibre channel name-server entries, not zoneset activation state.

D:

Tightly scoped FC zones limit which initiators can discover or communicate with designated targets. This concerns single-initiator zoning, not zoneset activation state.

Question 280

A blade has two configured vNICs, yet a failed fabric interconnect isolates all management and application traffic. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What is the best next implementation or troubleshooting step?

  1. Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities.
  2. Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs.
  3. Create and secure an appropriate management configuration backup before a major maintenance operation.
  4. Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path.

Explanation

Correct Answer

B:

Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs. Logical dual vNIC definitions provide resilience only when each has a functioning independent physical fabric path. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities. This concerns UCS blade chassis IOM discovery, not UCS fabric redundancy.

C:

Create and secure an appropriate management configuration backup before a major maintenance operation. This concerns UCS management backup, not UCS fabric redundancy.

D:

Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path. This concerns UCS VLAN pool and template, not UCS fabric redundancy.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.