Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 6

Question 50

A UCS fabric interconnect in NPV mode can establish an FC physical uplink but attached server vHBAs cannot complete login. A storage change board requires a traceable diagnosis before allowing further fabric changes. What is the best next implementation or troubleshooting step?

  1. Update the device alias to the authorized new WWPN and validate all zoning references before applying it.
  2. Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning.
  3. Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets.
  4. Validate physical FC link and initiator FLOGI registration before changing storage-array masking.

Explanation

Correct Answer

B:

Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. NPV proxies initiator logins through an upstream fabric switch, which must support the required virtual-port logins. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Update the device alias to the authorized new WWPN and validate all zoning references before applying it. That response is associated with device alias maintenance rather than the specific npv uplink fabric services condition described here. For the stated failure, the preferred action is: Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. Relevant evidence: Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

C:

Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. That response is associated with vsan isolation rather than the specific npv uplink fabric services condition described here. For the stated failure, the preferred action is: Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. Relevant evidence: Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

D:

Validate physical FC link and initiator FLOGI registration before changing storage-array masking. This concerns fibre channel fabric login, not npv uplink fabric services.

Question 51

A server sees intermittent TCP resets, but an administrator only has coarse interface error counters. The team is preparing a controlled production change and must preserve fabric reachability. Which qualification should the change record include?

  1. A configuration backup alone does not prove the running state matches approved policy.
  2. An oversubscribed SPAN destination can drop mirrored frames, so a capture is not necessarily complete.
  3. Sampled flow records may underrepresent small or short flows and do not contain every packet payload.
  4. Calling an image upgrade ISSU does not guarantee zero packet loss or no feature-specific disruption.

Explanation

Correct Answer

B:

An oversubscribed SPAN destination can drop mirrored frames, so a capture is not necessarily complete. SPAN copies selected frames for packet inspection when protocol-level behavior is not visible in summarized counters. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

A configuration backup alone does not prove the running state matches approved policy. This concerns fabric configuration drift, not span packet-level diagnosis.

C:

Sampled flow records may underrepresent small or short flows and do not contain every packet payload. This concerns netflow traffic attribution, not span packet-level diagnosis.

D:

Calling an image upgrade ISSU does not guarantee zero packet loss or no feature-specific disruption. This concerns nexus issu eligibility, not span packet-level diagnosis.

Question 52

A blade's vHBA is configured but the upstream SAN fabric never sees its WWPN login. Operations is validating the host before approving production workload placement. What post-change observation gives the strongest evidence of success?

  1. Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct.
  2. The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths.
  3. The intended traffic class meets its latency and drop requirements under a controlled mixed-load test.
  4. Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment.

Explanation

Correct Answer

B:

The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths. This result tests the original failure rather than reporting merely that the configuration command was accepted. A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct. That response is associated with wwpn pool allocation rather than the specific san connectivity from blade chassis condition described here. For the stated failure, the preferred action is: Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. Relevant evidence: Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries. Operations is validating the host before approving production workload placement.

C:

The intended traffic class meets its latency and drop requirements under a controlled mixed-load test. That response is associated with ucs network qos policy rather than the specific san connectivity from blade chassis condition described here. For the stated failure, the preferred action is: Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. Relevant evidence: Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries. Operations is validating the host before approving production workload placement.

D:

Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment. This concerns UCS mac pool uniqueness, not SAN connectivity from blade chassis.

Question 53

A four-link server port-channel forwards on two members because the other members use incompatible trunk settings. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What should the engineer collect before ruling out other causes?

  1. Inspect root bridge identity, port role, path cost and topology-change counters.
  2. Inspect port-channel summaries, actor/partner keys, VLAN and speed settings and member suspension reasons.
  3. Inspect the target EPLD release notes, affected module types, reload requirements and redundancy state.
  4. Inspect peer-link state, peer-keepalive reachability, consistency checks and suspended port reasons.

Explanation

Correct Answer

B:

Inspect port-channel summaries, actor/partner keys, VLAN and speed settings and member suspension reasons. These records help distinguish the suspected failure from a superficially similar fault before modifying production. LACP aggregates only compatible interfaces, and inconsistent operational settings can suspend members. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

Inspect root bridge identity, port role, path cost and topology-change counters. This concerns rstp blocked uplink, not lacp member mismatch.

C:

Inspect the target EPLD release notes, affected module types, reload requirements and redundancy state. This concerns epld firmware maintenance, not lacp member mismatch.

D:

Inspect peer-link state, peer-keepalive reachability, consistency checks and suspended port reasons. This concerns vpc peer-link recovery, not lacp member mismatch.

Question 54

Two application teams use the same physical SAN switches but must keep their fabric control traffic separated. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. Which observations would best validate the initial diagnosis?

  1. Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs.
  2. Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples.
  3. Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs.
  4. Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries.

Explanation

Correct Answer

A:

Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. VSANs provide logical fabric separation across shared physical Fibre Channel infrastructure. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.

Incorrect Answers

B:

Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples. This concerns SAN port error telemetry, not VSAN isolation.

C:

Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. This concerns npv uplink fabric services, not VSAN isolation.

D:

Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. This concerns wwpn versus wwnn, not VSAN isolation.

Question 55

An administrator can see one domain in Intersight but cannot create profiles for a different business unit's assigned equipment. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. How should the implementation be validated against the original failure?

  1. Domain fabrics report successful policy deployment and carry the expected LAN and SAN traffic.
  2. The authorized team can create the required profiles only for its assigned infrastructure without gaining global rights.
  3. The chassis and blades enroll in the correct domain and receive valid Intersight-managed profiles.
  4. Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment.

Explanation

Correct Answer

B:

The authorized team can create the required profiles only for its assigned infrastructure without gaining global rights. This result tests the original failure rather than reporting merely that the configuration command was accepted. Intersight resource assignment and RBAC limit which infrastructure objects and policies an administrator can manage. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Domain fabrics report successful policy deployment and carry the expected LAN and SAN traffic. This concerns intersight domain profile, not intersight organization scope.

C:

The chassis and blades enroll in the correct domain and receive valid Intersight-managed profiles. This concerns UCS-x intersight managed mode, not intersight organization scope.

D:

Every active vNIC has a unique assigned MAC and upstream learning stays stable after deployment. This concerns UCS mac pool uniqueness, not intersight organization scope.

Question 56

A replacement management cluster is being restored from an old UCS backup while recently issued MAC and WWPN pools may differ. Operations is validating the host before approving production workload placement. Which qualification should the change record include?

  1. A high-availability label does not guarantee there is sufficient spare capacity for concurrent outages.
  2. A successful import message does not guarantee the restored configuration is current or conflict-free.
  3. A host operating-system backup does not replace the UCS management configuration backup.
  4. The newest firmware for each component is not necessarily a supported combination when mixed arbitrarily.

Explanation

Correct Answer

B:

A successful import message does not guarantee the restored configuration is current or conflict-free. Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

A high-availability label does not guarantee there is sufficient spare capacity for concurrent outages. This concerns UCS firmware change sequencing, not UCS restore integrity.

C:

A host operating-system backup does not replace the UCS management configuration backup. This concerns UCS management backup, not UCS restore integrity.

D:

The newest firmware for each component is not necessarily a supported combination when mixed arbitrarily. This concerns UCS firmware compatibility, not UCS restore integrity.

Question 57

Two application teams use the same physical SAN switches but must keep their fabric control traffic separated. A storage change board requires a traceable diagnosis before allowing further fabric changes. What should the engineer collect before ruling out other causes?

  1. Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries.
  2. Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events.
  3. Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs.
  4. Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs.

Explanation

Correct Answer

D:

Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. VSANs provide logical fabric separation across shared physical Fibre Channel infrastructure. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. That response is associated with wwpn versus wwnn rather than the specific vsan isolation condition described here. For the stated failure, the preferred action is: Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. Relevant evidence: Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

B:

Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events. This concerns fibre channel fabric login, not VSAN isolation.

C:

Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. That response is associated with npv uplink fabric services rather than the specific vsan isolation condition described here. For the stated failure, the preferred action is: Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. Relevant evidence: Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Question 58

During an east-west bandwidth surge, interface counters rise but do not reveal which applications or source subnets dominate. The team is preparing a controlled production change and must preserve fabric reachability. What information should be inspected before the change is applied?

  1. Inspect VNI membership, head-end replication peers, ARP traffic and remote VTEP encapsulation.
  2. Inspect exporter/collector status, flow sample records, talker pairs and time-aligned interface utilization.
  3. Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults.
  4. Inspect fabric membership, node discovery events, infra connectivity and APIC registration details.

Explanation

Correct Answer

B:

Inspect exporter/collector status, flow sample records, talker pairs and time-aligned interface utilization. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Flow records expose traffic conversations and volume patterns that interface-level totals cannot distinguish. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Inspect VNI membership, head-end replication peers, ARP traffic and remote VTEP encapsulation. This concerns bum replication behavior, not netflow traffic attribution.

C:

Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults. This concerns aci access policy chain, not netflow traffic attribution.

D:

Inspect fabric membership, node discovery events, infra connectivity and APIC registration details. This concerns aci fabric discovery, not netflow traffic attribution.

Question 59

A C-Series host repeatedly boots local media even though its approved UCS policy specifies a SAN boot target. Operations is validating the host before approving production workload placement. Which intervention most directly addresses the stated condition?

  1. Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities.
  2. Validate the service-profile SAN boot target WWPN/LUN settings and underlying zoning/masking path.
  3. Compare the effective service profile boot policy with the physical and SAN targets visible to the server.
  4. Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks.

Explanation

Correct Answer

C:

Compare the effective service profile boot policy with the physical and SAN targets visible to the server. The effective boot order and accessible target devices determine which source a Cisco server attempts during initialization. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities. This concerns wwpn pool allocation, not c-series boot policy alignment.

B:

Validate the service-profile SAN boot target WWPN/LUN settings and underlying zoning/masking path. This concerns SAN boot path policy, not c-series boot policy alignment.

D:

Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. This concerns SAN connectivity from blade chassis, not c-series boot policy alignment.

Question 60

A server sees intermittent TCP resets, but an administrator only has coarse interface error counters. The team is preparing a controlled production change and must preserve fabric reachability. Which observations would best validate the initial diagnosis?

  1. Inspect VNI-to-VRF mappings, NVE membership, route targets and tenant route tables.
  2. Inspect VMM controller connectivity, domain association, VM port-group mapping and endpoint events.
  3. Inspect SPAN source/destination selection, capture timestamps, TCP flags and any truncation or drop counters.
  4. Inspect loopback addresses, underlay routes, tunnel source settings and VTEP reachability.

Explanation

Correct Answer

C:

Inspect SPAN source/destination selection, capture timestamps, TCP flags and any truncation or drop counters. These records help distinguish the suspected failure from a superficially similar fault before modifying production. SPAN copies selected frames for packet inspection when protocol-level behavior is not visible in summarized counters. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Inspect VNI-to-VRF mappings, NVE membership, route targets and tenant route tables. This concerns evpn vni-to-vrf mapping, not span packet-level diagnosis.

B:

Inspect VMM controller connectivity, domain association, VM port-group mapping and endpoint events. This concerns aci vmm association, not span packet-level diagnosis.

D:

Inspect loopback addresses, underlay routes, tunnel source settings and VTEP reachability. This concerns vxlan vtep underlay reachability, not span packet-level diagnosis.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.