Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 5

Question 40

A blade's vHBA is configured but the upstream SAN fabric never sees its WWPN login. Operations is validating the host before approving production workload placement. Which technical principle best explains the recommended response?

  1. QoS treatment is effective only when marking, queue allocation and congestion behavior align across involved devices.
  2. A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur.
  3. A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts.
  4. Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably.

Explanation

Correct Answer

B:

A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

QoS treatment is effective only when marking, queue allocation and congestion behavior align across involved devices. That response is associated with ucs network qos policy rather than the specific san connectivity from blade chassis condition described here. For the stated failure, the preferred action is: Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. Relevant evidence: Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries. Operations is validating the host before approving production workload placement.

C:

A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts. This concerns boot order and removable media, not SAN connectivity from blade chassis.

D:

Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably. That response is associated with wwpn pool allocation rather than the specific san connectivity from blade chassis condition described here. For the stated failure, the preferred action is: Validate the UCS SAN uplink, vHBA fabric pinning and VSAN assignment before modifying LUN masks. Relevant evidence: Inspect vHBA identity, SAN uplink operational state, VSAN mapping and upstream FLOGI entries. Operations is validating the host before approving production workload placement.

Question 41

A Nexus access VLAN with Dynamic ARP Inspection enabled begins dropping legitimate hosts that use static addressing. Security engineering must restore the approved service without relaxing unrelated protection. What post-change observation gives the strongest evidence of success?

  1. The administrator can inspect zone status while unauthorized zone modification is blocked and recorded.
  2. Tagged VMs appear in the intended microsegmented EPG and only approved flows traverse the boundary.
  3. Authorized static hosts pass ARP inspection while forged bindings remain blocked.
  4. Clients obtain leases from the authorized server and rogue DHCP replies on access ports are still rejected.

Explanation

Correct Answer

C:

Authorized static hosts pass ARP inspection while forged bindings remain blocked. This result tests the original failure rather than reporting merely that the configuration command was accepted. DAI verifies ARP bindings using trusted information and may reject legitimate fixed-address hosts without an authorized binding. Security engineering must restore the approved service without relaxing unrelated protection.

Incorrect Answers

A:

The administrator can inspect zone status while unauthorized zone modification is blocked and recorded. This concerns mds SAN administrative control, not dynamic ARP inspection source of truth.

B:

Tagged VMs appear in the intended microsegmented EPG and only approved flows traverse the boundary. That response is associated with aci microsegmentation selector rather than the specific dynamic arp inspection source of truth condition described here. For the stated failure, the preferred action is: Validate DAI binding sources and configure a supported static ARP ACL or binding for the approved fixed-address hosts. Relevant evidence: Inspect DAI drop counters, DHCP snooping binding table, static host assignments and ARP inspection logs. Security engineering must restore the approved service without relaxing unrelated protection.

D:

Clients obtain leases from the authorized server and rogue DHCP replies on access ports are still rejected. That response is associated with dhcp snooping trusted uplink rather than the specific dynamic arp inspection source of truth condition described here. For the stated failure, the preferred action is: Validate DAI binding sources and configure a supported static ARP ACL or binding for the approved fixed-address hosts. Relevant evidence: Inspect DAI drop counters, DHCP snooping binding table, static host assignments and ARP inspection logs. Security engineering must restore the approved service without relaxing unrelated protection.

Question 42

Updating a UCS updating-template appears to change vNIC settings on more blades than intended. Operations is validating the host before approving production workload placement. Which technical principle best explains the recommended response?

  1. Updating templates can propagate modifications to associated service profiles; change impact depends on associations.
  2. A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts.
  3. Hardware alerts require component-level evidence; unrelated performance alarms may have a separate root cause.
  4. Pool qualification policies can restrict association based on compatible server hardware characteristics.

Explanation

Correct Answer

A:

Updating templates can propagate modifications to associated service profiles; change impact depends on associations. Operations is validating the host before approving production workload placement.

Incorrect Answers

B:

A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts. That response is associated with boot order and removable media rather than the specific updating service-profile templates condition described here. For the stated failure, the preferred action is: Stage and review the template relationship and scope before applying an impactful shared-policy change. Relevant evidence: Inspect parent templates, derived profiles, policy inheritance and pending association changes. Operations is validating the host before approving production workload placement.

C:

Hardware alerts require component-level evidence; unrelated performance alarms may have a separate root cause. This concerns intersight alert triage, not updating service-profile templates.

D:

Pool qualification policies can restrict association based on compatible server hardware characteristics. That response is associated with server pool qualification rather than the specific updating service-profile templates condition described here. For the stated failure, the preferred action is: Stage and review the template relationship and scope before applying an impactful shared-policy change. Relevant evidence: Inspect parent templates, derived profiles, policy inheritance and pending association changes. Operations is validating the host before approving production workload placement.

Question 43

Two production Nexus peers have drifted in their intended interface templates after unreviewed local commands were applied. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which evidence set most directly tests the suspected failure?

  1. Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults.
  2. Inspect configuration diffs, change tickets, inventory assignments and last known working backups.
  3. Inspect loopback addresses, underlay routes, tunnel source settings and VTEP reachability.
  4. Inspect VMM controller connectivity, domain association, VM port-group mapping and endpoint events.

Explanation

Correct Answer

B:

Inspect configuration diffs, change tickets, inventory assignments and last known working backups. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Configuration management detects and remediates unauthorized deviations rather than trusting the most recent device state. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults. This concerns aci access policy chain, not fabric configuration drift.

C:

Inspect loopback addresses, underlay routes, tunnel source settings and VTEP reachability. This concerns vxlan vtep underlay reachability, not fabric configuration drift.

D:

Inspect VMM controller connectivity, domain association, VM port-group mapping and endpoint events. This concerns aci vmm association, not fabric configuration drift.

Question 44

An administrator can see one domain in Intersight but cannot create profiles for a different business unit's assigned equipment. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What information should be inspected before the change is applied?

  1. Inspect capture-point support, vNIC policy, frame timestamps, queue counters and retransmission patterns.
  2. Inspect domain claim, domain profile bindings, uplink policies and deployment events.
  3. Inspect resource groups, organizations, assigned roles and actual inventory associations.
  4. Inspect connected domain registration, Intersight inventory, firmware compatibility and target policy types.

Explanation

Correct Answer

C:

Inspect resource groups, organizations, assigned roles and actual inventory associations. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Intersight resource assignment and RBAC limit which infrastructure objects and policies an administrator can manage. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Inspect capture-point support, vNIC policy, frame timestamps, queue counters and retransmission patterns. This concerns compute traffic span, not intersight organization scope.

B:

Inspect domain claim, domain profile bindings, uplink policies and deployment events. This concerns intersight domain profile, not intersight organization scope.

D:

Inspect connected domain registration, Intersight inventory, firmware compatibility and target policy types. This concerns UCS-x intersight managed mode, not intersight organization scope.

Question 45

Network and storage policies appear correct individually, but a newly claimed UCS domain has no effective fabric uplink configuration. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What should the engineer collect before ruling out other causes?

  1. Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs.
  2. Inspect domain claim, domain profile bindings, uplink policies and deployment events.
  3. Inspect resource groups, organizations, assigned roles and actual inventory associations.
  4. Inspect connected domain registration, Intersight inventory, firmware compatibility and target policy types.

Explanation

Correct Answer

B:

Inspect domain claim, domain profile bindings, uplink policies and deployment events. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Intersight Managed Mode applies shared domain-level fabric configuration through domain profiles and associated policies. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs. This concerns UCS blade chassis IOM discovery, not intersight domain profile.

C:

Inspect resource groups, organizations, assigned roles and actual inventory associations. This concerns intersight organization scope, not intersight domain profile.

D:

Inspect connected domain registration, Intersight inventory, firmware compatibility and target policy types. This concerns UCS-x intersight managed mode, not intersight domain profile.

Question 46

An unauthorized initiator plugs into an available SAN switch port and attempts fabric login using an unapproved WWPN. Security engineering must restore the approved service without relaxing unrelated protection. Which limitation prevents the team from overgeneralizing this result?

  1. A user with no host storage access might still alter SAN switch policy if management RBAC is too broad.
  2. Permissive fabric zoning does not itself guarantee that an unauthorized physical initiator cannot log in.
  3. Host-level WWPN zoning is not a substitute for constraining switch-to-switch fabric membership.
  4. Limiting server operating-system permissions does not automatically restrict UCS management-plane roles.

Explanation

Correct Answer

B:

Permissive fabric zoning does not itself guarantee that an unauthorized physical initiator cannot log in. FC port security can restrict which device WWNs are permitted to connect through designated fabric ports. Security engineering must restore the approved service without relaxing unrelated protection.

Incorrect Answers

A:

A user with no host storage access might still alter SAN switch policy if management RBAC is too broad. That response is associated with mds san administrative control rather than the specific fibre channel port security condition described here. For the stated failure, the preferred action is: Configure approved Fibre Channel port-security bindings and verify rejection of unregistered identities. Relevant evidence: Inspect port-security policy, learned WWPNs, interface events and attempted fabric logins. Security engineering must restore the approved service without relaxing unrelated protection.

C:

Host-level WWPN zoning is not a substitute for constraining switch-to-switch fabric membership. That response is associated with fabric binding membership rather than the specific fibre channel port security condition described here. For the stated failure, the preferred action is: Configure approved Fibre Channel port-security bindings and verify rejection of unregistered identities. Relevant evidence: Inspect port-security policy, learned WWPNs, interface events and attempted fabric logins. Security engineering must restore the approved service without relaxing unrelated protection.

D:

Limiting server operating-system permissions does not automatically restrict UCS management-plane roles. This concerns UCS administrative separation, not fibre channel port security.

Question 47

A new C-Series rack server powers on but its management controller cannot be reached from the secure operations subnet. Operations is validating the host before approving production workload placement. Which observations would best validate the initial diagnosis?

  1. Inspect backup type, completion logs, storage location, retention and access permissions.
  2. Inspect CIMC settings, switchport VLAN, cabling, gateway and adjacent interface state.
  3. Inspect backup timestamp, pool assignments, profile associations and supported restore-mode prerequisites.
  4. Inspect chassis health, power budgets, fan alarms, temperature sensors and affected blade performance.

Explanation

Correct Answer

B:

Inspect CIMC settings, switchport VLAN, cabling, gateway and adjacent interface state. These records help distinguish the suspected failure from a superficially similar fault before modifying production. The CIMC out-of-band interface requires correctly configured management connectivity independent of the installed server operating system. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Inspect backup type, completion logs, storage location, retention and access permissions. This concerns UCS management backup, not UCS c-series cimc reachability.

C:

Inspect backup timestamp, pool assignments, profile associations and supported restore-mode prerequisites. This concerns UCS restore integrity, not UCS c-series cimc reachability.

D:

Inspect chassis health, power budgets, fan alarms, temperature sensors and affected blade performance. This concerns chassis power and thermal monitoring, not UCS c-series cimc reachability.

Question 48

An administrator can see one domain in Intersight but cannot create profiles for a different business unit's assigned equipment. Operations is validating the host before approving production workload placement. Which observations would best validate the initial diagnosis?

  1. Inspect CIMC settings, switchport VLAN, cabling, gateway and adjacent interface state.
  2. Inspect domain claim, domain profile bindings, uplink policies and deployment events.
  3. Inspect connected domain registration, Intersight inventory, firmware compatibility and target policy types.
  4. Inspect resource groups, organizations, assigned roles and actual inventory associations.

Explanation

Correct Answer

D:

Inspect resource groups, organizations, assigned roles and actual inventory associations. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Intersight resource assignment and RBAC limit which infrastructure objects and policies an administrator can manage. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Inspect CIMC settings, switchport VLAN, cabling, gateway and adjacent interface state. This concerns UCS c-series cimc reachability, not intersight organization scope.

B:

Inspect domain claim, domain profile bindings, uplink policies and deployment events. That response is associated with intersight domain profile rather than the specific intersight organization scope condition described here. For the stated failure, the preferred action is: Check organization membership and resource-group scope before broadening permissions globally. Relevant evidence: Inspect resource groups, organizations, assigned roles and actual inventory associations. Operations is validating the host before approving production workload placement.

C:

Inspect connected domain registration, Intersight inventory, firmware compatibility and target policy types. That response is associated with ucs-x intersight managed mode rather than the specific intersight organization scope condition described here. For the stated failure, the preferred action is: Check organization membership and resource-group scope before broadening permissions globally. Relevant evidence: Inspect resource groups, organizations, assigned roles and actual inventory associations. Operations is validating the host before approving production workload placement.

Question 49

An NX-OS switch logs an uplink failure but an EEM policy intended to notify the NOC never triggers. The automation change must pass a preproduction test and leave a verifiable audit trail. Which qualification should the change record include?

  1. Enabling Guest Shell does not grant arbitrary host or network filesystem access by default.
  2. A successful playbook exit code alone does not show that no unintended configuration drift occurred.
  3. An EEM event match does not prove a remediation command is safe or authorized to execute automatically.
  4. A scheduler cannot guarantee success if script dependencies or device privileges are missing.

Explanation

Correct Answer

C:

An EEM event match does not prove a remediation command is safe or authorized to execute automatically. Embedded Event Manager runs configured actions in response to matching local events and authorization constraints. The automation change must pass a preproduction test and leave a verifiable audit trail.

Incorrect Answers

A:

Enabling Guest Shell does not grant arbitrary host or network filesystem access by default. That response is associated with guest shell isolation rather than the specific eem syslog-triggered remediation condition described here. For the stated failure, the preferred action is: Validate the event detector pattern, applet registration and permitted action under the intended NX-OS context. Relevant evidence: Inspect EEM detector configuration, actual syslog message, applet history and action permissions. The automation change must pass a preproduction test and leave a verifiable audit trail.

B:

A successful playbook exit code alone does not show that no unintended configuration drift occurred. This concerns ansible idempotent templates, not eem syslog-triggered remediation.

D:

A scheduler cannot guarantee success if script dependencies or device privileges are missing. That response is associated with nx-os scheduler jobs rather than the specific eem syslog-triggered remediation condition described here. For the stated failure, the preferred action is: Validate the event detector pattern, applet registration and permitted action under the intended NX-OS context. Relevant evidence: Inspect EEM detector configuration, actual syslog message, applet history and action permissions. The automation change must pass a preproduction test and leave a verifiable audit trail.

Question 50

A UCS fabric interconnect in NPV mode can establish an FC physical uplink but attached server vHBAs cannot complete login. A storage change board requires a traceable diagnosis before allowing further fabric changes. What is the best next implementation or troubleshooting step?

  1. Update the device alias to the authorized new WWPN and validate all zoning references before applying it.
  2. Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning.
  3. Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets.
  4. Validate physical FC link and initiator FLOGI registration before changing storage-array masking.

Explanation

Correct Answer

B:

Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. NPV proxies initiator logins through an upstream fabric switch, which must support the required virtual-port logins. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Update the device alias to the authorized new WWPN and validate all zoning references before applying it. That response is associated with device alias maintenance rather than the specific npv uplink fabric services condition described here. For the stated failure, the preferred action is: Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. Relevant evidence: Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

C:

Create and verify separate VSAN assignments for the teams' relevant FC interfaces and zonesets. That response is associated with vsan isolation rather than the specific npv uplink fabric services condition described here. For the stated failure, the preferred action is: Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. Relevant evidence: Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. A storage change board requires a traceable diagnosis before allowing further fabric changes.

D:

Validate physical FC link and initiator FLOGI registration before changing storage-array masking. This concerns fibre channel fabric login, not npv uplink fabric services.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.