Pass Your CompTIA 220-1201 Exam Easy!

CompTIA 220-1201 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

220-1201 Premium Bundle

$79.99

CompTIA 220-1201 Premium Bundle

220-1201 Premium File: 527 Questions & Answers

Last Update: Oct 05, 2026

220-1201 Training Course: 106 Video Lectures

220-1201 PDF Study Guide: 2615 Pages

220-1201 Bundle gives you unlimited access to "220-1201" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
CompTIA 220-1201 Premium Bundle
CompTIA 220-1201 Premium Bundle

220-1201 Premium File: 527 Questions & Answers

Last Update: Oct 05, 2026

220-1201 Training Course: 106 Video Lectures

220-1201 PDF Study Guide: 2615 Pages

$79.99

220-1201 Bundle gives you unlimited access to "220-1201" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

CompTIA 220-1201 Practice Test 9

Question 80

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A printer displays 'driver unavailable' only on newly upgraded clients while older computers continue printing. A confidential document prints immediately into an open public tray, even though company policy requires badge pickup. Which course of action addresses the stated issues?

  1. Clear the affected workstation's stuck queue and reestablish its approved printer connection; update its printer port or configure an approved DHCP reservation.
  2. Install a supported driver package compatible with the upgraded operating system; enable secured print release and verify badge-based retrieval for the affected queue.
  3. Clear the affected workstation's stuck queue and reestablish its approved printer connection; enable secured print release and verify badge-based retrieval for the affected queue.
  4. Install a supported driver package compatible with the upgraded operating system; update its printer port or configure an approved DHCP reservation.

Explanation

Correct Answer

B:

For ticket (1), A printer device can be healthy while client software lacks a compatible print driver. For ticket (2), A configured printer can function mechanically while violating output confidentiality controls.

Incorrect Answers

A:

For ticket 1, install a supported driver package compatible with the upgraded operating system. A printer device can be healthy while client software lacks a compatible print driver. For ticket 2, enable secured print release and verify badge-based retrieval for the affected queue. A configured printer can function mechanically while violating output confidentiality controls.

C:

For ticket 1, install a supported driver package compatible with the upgraded operating system. A printer device can be healthy while client software lacks a compatible print driver.

D:

For ticket 2, enable secured print release and verify badge-based retrieval for the affected queue. A configured printer can function mechanically while violating output confidentiality controls.

Question 81

A service coordinator has THREE separate support tickets and needs the correct matching actions: One employee's print job remains in the local spooler while colleagues print successfully to the same shared device. A shared printer has a valid IP address but jobs sent to its old address disappear after a DHCP scope change. A printer displays 'driver unavailable' only on newly upgraded clients while older computers continue printing. Which response best addresses these needs?

  1. Enable secured print release and verify badge-based retrieval for the affected queue; update its printer port or configure an approved DHCP reservation; and install a supported driver package compatible with the upgraded operating system.
  2. Clear the affected workstation's stuck queue and reestablish its approved printer connection; enable secured print release and verify badge-based retrieval for the affected queue; and install a supported driver package compatible with the upgraded operating system.
  3. Clear the affected workstation's stuck queue and reestablish its approved printer connection; update its printer port or configure an approved DHCP reservation; and enable secured print release and verify badge-based retrieval for the affected queue.
  4. Clear the affected workstation's stuck queue and reestablish its approved printer connection; update its printer port or configure an approved DHCP reservation; and install a supported driver package compatible with the upgraded operating system.

Explanation

Correct Answer

D:

For ticket (1), A client-specific blocked queue can prevent printing even when the shared printer is healthy. For ticket (2), Device addressing changes can orphan clients configured to print to an old network endpoint. For ticket (3), A printer device can be healthy while client software lacks a compatible print driver.

Incorrect Answers

A:

For ticket 1, clear the affected workstation's stuck queue and reestablish its approved printer connection. A client-specific blocked queue can prevent printing even when the shared printer is healthy.

B:

For ticket 2, update its printer port or configure an approved DHCP reservation. Device addressing changes can orphan clients configured to print to an old network endpoint.

C:

For ticket 3, install a supported driver package compatible with the upgraded operating system. A printer device can be healthy while client software lacks a compatible print driver.

Question 82

A field technician verifies the following customer equipment condition: A compact computer has an M.2 socket that supports only SATA, and a technician purchases a PCIe NVMe-only drive. Which response BEST addresses the actual cause or requirement?

  1. Verify the socket's protocol/key support and select an electrically compatible SSD.
  2. Choose an appropriate NVMe SSD for the required random I/O and throughput workload.
  3. Use a supported SAS host controller/backplane or select a compatible SATA drive.
  4. Verify the storage medium independently of the drive's physical form factor.

Explanation

Correct Answer

A:

M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces.

Incorrect Answers

B:

Choosing an appropriate NVMe SSD for the required random I/O and throughput workload would not verify the socket's protocol/key support and select an electrically compatible SSD.

C:

Using a supported SAS host controller/backplane or select a compatible SATA drive would not verify the socket's protocol/key support and select an electrically compatible SSD.

D:

Verifying the storage medium independently of the drive's physical form factor would not verify the socket's protocol/key support and select an electrically compatible SSD.

Question 83

An IT support worker is asked to resolve this case: A workstation needs fast parallel storage access, and the designer compares a mechanical 7200 rpm HDD to a PCIe NVMe SSD. Which next step MOST directly resolves the reported condition?

  1. Verify the storage medium independently of the drive's physical form factor.
  2. Verify the socket's protocol/key support and select an electrically compatible SSD.
  3. Choose an appropriate NVMe SSD for the required random I/O and throughput workload.
  4. Use a supported SAS host controller/backplane or select a compatible SATA drive.

Explanation

Correct Answer

C:

NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

Incorrect Answers

A:

Form factors describe package dimensions and can contain different media types; nVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

B:

M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces; nVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

D:

SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging; nVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

Question 84

A service bench observes this hardware or network symptom: A server technician orders a SAS enterprise drive for a consumer SATA-only motherboard without a SAS controller. What should the support specialist recommend FIRST within the stated limits?

  1. Verify the storage medium independently of the drive's physical form factor.
  2. Verify the socket's protocol/key support and select an electrically compatible SSD.
  3. Choose an appropriate NVMe SSD for the required random I/O and throughput workload.
  4. Use a supported SAS host controller/backplane or select a compatible SATA drive.

Explanation

Correct Answer

D:

SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

Incorrect Answers

A:

Form factors describe package dimensions and can contain different media types; sAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

B:

M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces; sAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

C:

NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks; sAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

Question 85

During a controlled office IT maintenance window, the technician notes: An archive user assumes a 2.5-inch drive always contains flash memory while a 3.5-inch drive always contains spinning platters. What is the MOST appropriate technician action?

  1. Choose an appropriate NVMe SSD for the required random I/O and throughput workload.
  2. Use a supported SAS host controller/backplane or select a compatible SATA drive.
  3. Verify the storage medium independently of the drive's physical form factor.
  4. Verify the socket's protocol/key support and select an electrically compatible SSD.

Explanation

Correct Answer

C:

Form factors describe package dimensions and can contain different media types.

Incorrect Answers

A:

Choosing an appropriate NVMe SSD for the required random I/O and throughput workload would not verify the storage medium independently of the drive's physical form factor.

B:

Using a supported SAS host controller/backplane or select a compatible SATA drive would not verify the storage medium independently of the drive's physical form factor.

D:

Verifying the socket's protocol/key support and selecting an electrically compatible SSD would not verify the storage medium independently of the drive's physical form factor.

Question 86

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A compact computer has an M.2 socket that supports only SATA, and a technician purchases a PCIe NVMe-only drive. A workstation needs fast parallel storage access, and the designer compares a mechanical 7200 rpm HDD to a PCIe NVMe SSD. Which course of action addresses the stated issues?

  1. Use a supported SAS host controller/backplane or select a compatible SATA drive; choose an appropriate NVMe SSD for the required random I/O and throughput workload.
  2. Verify the socket's protocol/key support and select an electrically compatible SSD; verify the storage medium independently of the drive's physical form factor.
  3. Use a supported SAS host controller/backplane or select a compatible SATA drive; verify the storage medium independently of the drive's physical form factor.
  4. Verify the socket's protocol/key support and select an electrically compatible SSD; choose an appropriate NVMe SSD for the required random I/O and throughput workload.

Explanation

Correct Answer

D:

For ticket (1), M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces. For ticket (2), NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

Incorrect Answers

A:

For ticket 1, verify the socket's protocol/key support and select an electrically compatible SSD. M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces.

B:

For ticket 2, choose an appropriate NVMe SSD for the required random I/O and throughput workload. NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

C:

For ticket 1, verify the socket's protocol/key support and select an electrically compatible SSD. M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces. For ticket 2, choose an appropriate NVMe SSD for the required random I/O and throughput workload. NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

Question 87

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A compact computer has an M.2 socket that supports only SATA, and a technician purchases a PCIe NVMe-only drive. A server technician orders a SAS enterprise drive for a consumer SATA-only motherboard without a SAS controller. Which response best addresses these needs?

  1. Verify the socket's protocol/key support and select an electrically compatible SSD; use a supported SAS host controller/backplane or select a compatible SATA drive.
  2. Choose an appropriate NVMe SSD for the required random I/O and throughput workload; use a supported SAS host controller/backplane or select a compatible SATA drive.
  3. Verify the socket's protocol/key support and select an electrically compatible SSD; verify the storage medium independently of the drive's physical form factor.
  4. Choose an appropriate NVMe SSD for the required random I/O and throughput workload; verify the storage medium independently of the drive's physical form factor.

Explanation

Correct Answer

A:

For ticket (1), M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces. For ticket (2), SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

Incorrect Answers

B:

For ticket 1, verify the socket's protocol/key support and select an electrically compatible SSD. M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces.

C:

For ticket 2, use a supported SAS host controller/backplane or select a compatible SATA drive. SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

D:

For ticket 1, verify the socket's protocol/key support and select an electrically compatible SSD. M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces. For ticket 2, use a supported SAS host controller/backplane or select a compatible SATA drive. SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

Question 88

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A workstation needs fast parallel storage access, and the designer compares a mechanical 7200 rpm HDD to a PCIe NVMe SSD. An archive user assumes a 2.5-inch drive always contains flash memory while a 3.5-inch drive always contains spinning platters. What is the most appropriate plan for this situation?

  1. Verify the socket's protocol/key support and select an electrically compatible SSD; verify the storage medium independently of the drive's physical form factor.
  2. Choose an appropriate NVMe SSD for the required random I/O and throughput workload; use a supported SAS host controller/backplane or select a compatible SATA drive.
  3. Verify the socket's protocol/key support and select an electrically compatible SSD; use a supported SAS host controller/backplane or select a compatible SATA drive.
  4. Choose an appropriate NVMe SSD for the required random I/O and throughput workload; verify the storage medium independently of the drive's physical form factor.

Explanation

Correct Answer

D:

For ticket (1), NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks. For ticket (2), Form factors describe package dimensions and can contain different media types.

Incorrect Answers

A:

For ticket 1, choose an appropriate NVMe SSD for the required random I/O and throughput workload. NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

B:

For ticket 2, verify the storage medium independently of the drive's physical form factor. Form factors describe package dimensions and can contain different media types.

C:

For ticket 1, choose an appropriate NVMe SSD for the required random I/O and throughput workload. NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks. For ticket 2, verify the storage medium independently of the drive's physical form factor. Form factors describe package dimensions and can contain different media types.

Question 89

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A server technician orders a SAS enterprise drive for a consumer SATA-only motherboard without a SAS controller. An archive user assumes a 2.5-inch drive always contains flash memory while a 3.5-inch drive always contains spinning platters. Which course of action addresses the stated issues?

  1. Use a supported SAS host controller/backplane or select a compatible SATA drive; choose an appropriate NVMe SSD for the required random I/O and throughput workload.
  2. Verify the socket's protocol/key support and select an electrically compatible SSD; choose an appropriate NVMe SSD for the required random I/O and throughput workload.
  3. Use a supported SAS host controller/backplane or select a compatible SATA drive; verify the storage medium independently of the drive's physical form factor.
  4. Verify the socket's protocol/key support and select an electrically compatible SSD; verify the storage medium independently of the drive's physical form factor.

Explanation

Correct Answer

C:

For ticket (1), SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging. For ticket (2), Form factors describe package dimensions and can contain different media types.

Incorrect Answers

A:

For ticket 2, verify the storage medium independently of the drive's physical form factor. Form factors describe package dimensions and can contain different media types.

B:

For ticket 1, use a supported SAS host controller/backplane or select a compatible SATA drive. SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging. For ticket 2, verify the storage medium independently of the drive's physical form factor. Form factors describe package dimensions and can contain different media types.

D:

For ticket 1, use a supported SAS host controller/backplane or select a compatible SATA drive. SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

Question 90

A service coordinator has THREE separate support tickets and needs the correct matching actions: A compact computer has an M.2 socket that supports only SATA, and a technician purchases a PCIe NVMe-only drive. A workstation needs fast parallel storage access, and the designer compares a mechanical 7200 rpm HDD to a PCIe NVMe SSD. A server technician orders a SAS enterprise drive for a consumer SATA-only motherboard without a SAS controller. Which response best addresses these needs?

  1. Verify the socket's protocol/key support and select an electrically compatible SSD; verify the storage medium independently of the drive's physical form factor; and use a supported SAS host controller/backplane or select a compatible SATA drive.
  2. Verify the socket's protocol/key support and select an electrically compatible SSD; choose an appropriate NVMe SSD for the required random I/O and throughput workload; and verify the storage medium independently of the drive's physical form factor.
  3. Verify the socket's protocol/key support and select an electrically compatible SSD; choose an appropriate NVMe SSD for the required random I/O and throughput workload; and use a supported SAS host controller/backplane or select a compatible SATA drive.
  4. Verify the storage medium independently of the drive's physical form factor; choose an appropriate NVMe SSD for the required random I/O and throughput workload; and use a supported SAS host controller/backplane or select a compatible SATA drive.

Explanation

Correct Answer

C:

For ticket (1), M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces. For ticket (2), NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks. For ticket (3), SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

Incorrect Answers

A:

For ticket 2, choose an appropriate NVMe SSD for the required random I/O and throughput workload. NVMe on PCIe avoids mechanical seek delays and commonly outperforms rotating disks.

B:

For ticket 3, use a supported SAS host controller/backplane or select a compatible SATA drive. SAS drives cannot generally communicate with a SATA-only controller despite similar drive packaging.

D:

For ticket 1, verify the socket's protocol/key support and select an electrically compatible SSD. M.2 describes form factor, whereas SATA and NVMe over PCIe are distinct interfaces.


CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Purchase Individually

220-1201 Premium File

Premium File
220-1201 Premium File
527 Q&A
$76.99$69.99

220-1201 Training Video Course

Training Course
220-1201 Training Video Course
106 Lectures
$27.49$24.99

220-1201 Study Guide

Study Guide
220-1201 Study Guide
2615 PDF Pages
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.