Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 68

Question 670

A Linux workload can reach an NFS server by IP but receives access denied when mounting its application share. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. Why is the targeted engineering response justified in this situation?

  1. An EPLD update may reset affected SAN hardware even if a previous NX-OS patch required no outage.
  2. SAN nondisruptive upgrade support depends on exact software path, hardware redundancy and active feature constraints.
  3. NFS file access is controlled by network and export permissions, not Fibre Channel zoning.
  4. iSCSI uses IP transport and initiator-target session controls rather than Fibre Channel fabric login.

Explanation

Correct Answer

C:

NFS file access is controlled by network and export permissions, not Fibre Channel zoning. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.

Incorrect Answers

A:

An EPLD update may reset affected SAN hardware even if a previous NX-OS patch required no outage. This concerns mds epld update impact, not nfs export permissions.

B:

SAN nondisruptive upgrade support depends on exact software path, hardware redundancy and active feature constraints. This concerns mds nondisruptive upgrade planning, not nfs export permissions.

D:

iSCSI uses IP transport and initiator-target session controls rather than Fibre Channel fabric login. This concerns iscsi target discovery, not nfs export permissions.

Question 671

A Nexus access VLAN with Dynamic ARP Inspection enabled begins dropping legitimate hosts that use static addressing. A follow-up access review asks the team to validate the same boundary with a controlled negative test. What information should be inspected before the change is applied?

  1. Inspect DAI drop counters, DHCP snooping binding table, static host assignments and ARP inspection logs.
  2. Inspect UCS role privileges, organization assignments, recent actions and denied command records.
  3. Inspect VM attributes, uSeg EPG selectors, endpoint placement and resulting enforced contracts.
  4. Inspect DHCP snooping trust configuration, VLAN enrollment, packet drops and server uplink topology.

Explanation

Correct Answer

A:

Inspect DAI drop counters, DHCP snooping binding table, static host assignments and ARP inspection logs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. DAI verifies ARP bindings using trusted information and may reject legitimate fixed-address hosts without an authorized binding. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

B:

Inspect UCS role privileges, organization assignments, recent actions and denied command records. This concerns UCS administrative separation, not dynamic ARP inspection source of truth.

C:

Inspect VM attributes, uSeg EPG selectors, endpoint placement and resulting enforced contracts. This concerns aci microsegmentation selector, not dynamic ARP inspection source of truth.

D:

Inspect DHCP snooping trust configuration, VLAN enrollment, packet drops and server uplink topology. This concerns DHCP snooping trusted uplink, not dynamic ARP inspection source of truth.

Question 672

An operations platform polls hundreds of leaf switches too slowly to detect short control-plane events. The team is preparing a controlled production change and must preserve fabric reachability. Which observations would best validate the initial diagnosis?

  1. Inspect subscription configuration, sensor paths, timestamps, drop counters and collector ingestion.
  2. Inspect VNI-to-VRF mappings, NVE membership, route targets and tenant route tables.
  3. Inspect fabric membership, node discovery events, infra connectivity and APIC registration details.
  4. Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults.

Explanation

Correct Answer

A:

Inspect subscription configuration, sensor paths, timestamps, drop counters and collector ingestion. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Model-driven telemetry can provide pushed state updates more frequently than coarse periodic polling. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

B:

Inspect VNI-to-VRF mappings, NVE membership, route targets and tenant route tables. This concerns evpn vni-to-vrf mapping, not streaming telemetry health.

C:

Inspect fabric membership, node discovery events, infra connectivity and APIC registration details. This concerns aci fabric discovery, not streaming telemetry health.

D:

Inspect VLAN pool allocation, AEP association, domain assignment, policy-group binding and interface faults. This concerns aci access policy chain, not streaming telemetry health.

Question 673

A SAN-boot blade fails to discover the primary boot LUN even though the fibre channel interface shows link up. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. How should the implementation be validated against the original failure?

  1. The blade discovers the intended boot LUN and boots after a controlled restart.
  2. Domain fabrics report successful policy deployment and carry the expected LAN and SAN traffic.
  3. The workload profile attaches only to blades meeting the declared capacity and adapter criteria.
  4. Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct.

Explanation

Correct Answer

A:

The blade discovers the intended boot LUN and boots after a controlled restart. This result tests the original failure rather than reporting merely that the configuration command was accepted. SAN boot requires all of the initiator, fabric zoning, target presentation and boot policy to agree. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

B:

Domain fabrics report successful policy deployment and carry the expected LAN and SAN traffic. This concerns intersight domain profile, not SAN boot path policy.

C:

The workload profile attaches only to blades meeting the declared capacity and adapter criteria. This concerns server pool qualification, not SAN boot path policy.

D:

Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct. This concerns wwpn pool allocation, not SAN boot path policy.

Question 674

An infrastructure engineer changes a Nexus policy directly in production and an upcoming Terraform apply attempts to revert it unexpectedly. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. How should the implementation be validated against the original failure?

  1. The approved plan contains only intended changes and apply converges without surprising production reversions.
  2. The authorized profile is created with valid visible policy references and its deployment succeeds.
  3. The authorized client runs the intended read-only API call and receives the expected structured result.
  4. The job succeeds using protected credentials while committed scripts contain no reusable secret material.

Explanation

Correct Answer

A:

The approved plan contains only intended changes and apply converges without surprising production reversions. This result tests the original failure rather than reporting merely that the configuration command was accepted. Terraform compares declared infrastructure with observed resources and can undo unmanaged changes during apply. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.

Incorrect Answers

B:

The authorized profile is created with valid visible policy references and its deployment succeeds. This concerns intersight policy automation, not terraform plan and state.

C:

The authorized client runs the intended read-only API call and receives the expected structured result. This concerns nx-api request authorization, not terraform plan and state.

D:

The job succeeds using protected credentials while committed scripts contain no reusable secret material. This concerns powershell api token security, not terraform plan and state.

Question 675

An API workflow creates an Intersight server profile but fails because referenced policy objects belong to another inaccessible organization. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. What is the best next implementation or troubleshooting step?

  1. Verify organization scope and referenced policy identifiers before retrying the profile creation.
  2. Reconcile the approved desired configuration and actual state using plan review and controlled state management.
  3. Replace non-idempotent imperative commands with state-aware configuration modules and diff-based validation where supported.
  4. Move secrets to a supported secure secret store and scope the automation identity to required API permissions.

Explanation

Correct Answer

A:

Verify organization scope and referenced policy identifiers before retrying the profile creation. Intersight objects and their assignments must satisfy resource visibility and scope permissions. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.

Incorrect Answers

B:

Reconcile the approved desired configuration and actual state using plan review and controlled state management. This concerns terraform plan and state, not intersight policy automation.

C:

Replace non-idempotent imperative commands with state-aware configuration modules and diff-based validation where supported. This concerns ansible idempotent templates, not intersight policy automation.

D:

Move secrets to a supported secure secret store and scope the automation identity to required API permissions. This concerns powershell api token security, not intersight policy automation.

Question 676

A server sees intermittent TCP resets, but an administrator only has coarse interface error counters. The team is preparing a controlled production change and must preserve fabric reachability. Why is the targeted engineering response justified in this situation?

  1. Configuration management detects and remediates unauthorized deviations rather than trusting the most recent device state.
  2. Nondisruptive software upgrade support is platform, topology and image-path dependent and must be verified.
  3. SPAN copies selected frames for packet inspection when protocol-level behavior is not visible in summarized counters.
  4. Programmable-logic updates can require component reset or reload even when an unrelated software patch did not.

Explanation

Correct Answer

C:

SPAN copies selected frames for packet inspection when protocol-level behavior is not visible in summarized counters. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Configuration management detects and remediates unauthorized deviations rather than trusting the most recent device state. This concerns fabric configuration drift, not span packet-level diagnosis.

B:

Nondisruptive software upgrade support is platform, topology and image-path dependent and must be verified. This concerns nexus issu eligibility, not span packet-level diagnosis.

D:

Programmable-logic updates can require component reset or reload even when an unrelated software patch did not. This concerns epld firmware maintenance, not span packet-level diagnosis.

Question 677

A four-link server port-channel forwards on two members because the other members use incompatible trunk settings. The team is preparing a controlled production change and must preserve fabric reachability. Which test result best demonstrates restoration of the intended behavior?

  1. The intended root remains stable, the active forwarding path operates and the redundant link converges after a fault.
  2. Traffic flows identify the actual high-volume conversations and support a targeted capacity or policy fix.
  3. Peer-link adjacency and vPC consistency return healthy, and affected ports resume forwarding without a dual-active state.
  4. All intended links join the same logical bundle and traffic is distributed without individual member flaps.

Explanation

Correct Answer

D:

All intended links join the same logical bundle and traffic is distributed without individual member flaps. This result tests the original failure rather than reporting merely that the configuration command was accepted. LACP aggregates only compatible interfaces, and inconsistent operational settings can suspend members. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

The intended root remains stable, the active forwarding path operates and the redundant link converges after a fault. That response is associated with rstp blocked uplink rather than the specific lacp member mismatch condition described here. For the stated failure, the preferred action is: Align the switchport and LACP parameters across members before attempting to force them into the bundle. Relevant evidence: Inspect port-channel summaries, actor/partner keys, VLAN and speed settings and member suspension reasons. The team is preparing a controlled production change and must preserve fabric reachability.

B:

Traffic flows identify the actual high-volume conversations and support a targeted capacity or policy fix. This concerns netflow traffic attribution, not lacp member mismatch.

C:

Peer-link adjacency and vPC consistency return healthy, and affected ports resume forwarding without a dual-active state. That response is associated with vpc peer-link recovery rather than the specific lacp member mismatch condition described here. For the stated failure, the preferred action is: Align the switchport and LACP parameters across members before attempting to force them into the bundle. Relevant evidence: Inspect port-channel summaries, actor/partner keys, VLAN and speed settings and member suspension reasons. The team is preparing a controlled production change and must preserve fabric reachability.

Question 678

A Nexus vPC secondary suspends downstream vPC member ports when the peer-link goes down but peer-keepalive still reaches the primary. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What should the engineer do first to address the observed failure?

  1. Align the switchport and LACP parameters across members before attempting to force them into the bundle.
  2. Confirm the designated root and spanning-tree role before changing a port that is intentionally blocking a loop.
  3. Restore the peer-link and validate keepalive and vPC consistency rather than forcing both peers to forward independently.
  4. Configure and validate an appropriate first-hop redundancy group with a shared virtual gateway and healthy tracking.

Explanation

Correct Answer

C:

Restore the peer-link and validate keepalive and vPC consistency rather than forcing both peers to forward independently. With peer-link failure and a reachable peer, the secondary suspends vPC member ports to prevent loops and dual-active forwarding. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

Align the switchport and LACP parameters across members before attempting to force them into the bundle. This concerns lacp member mismatch, not vpc peer-link recovery.

B:

Confirm the designated root and spanning-tree role before changing a port that is intentionally blocking a loop. This concerns rstp blocked uplink, not vpc peer-link recovery.

D:

Configure and validate an appropriate first-hop redundancy group with a shared virtual gateway and healthy tracking. This concerns first-hop gateway failover, not vpc peer-link recovery.

Question 679

An administrator imports a service-profile template and two new server identities unexpectedly request an overlapping MAC range. Operations is validating the host before approving production workload placement. Which limitation prevents the team from overgeneralizing this result?

  1. Adding a VLAN only to the upstream switch does not attach it automatically to the UCS vNIC template.
  2. Two vNIC objects on the same failed upstream path do not provide true physical redundancy.
  3. A high-priority label inside UCS does not guarantee every upstream switch honors that class.
  4. Changing the displayed server name does not resolve a duplicate effective network identifier.

Explanation

Correct Answer

D:

Changing the displayed server name does not resolve a duplicate effective network identifier. UCS identity pools must avoid reuse because overlapping MAC addresses can cause Layer 2 instability and confusing endpoint learning. Operations is validating the host before approving production workload placement.

Incorrect Answers

A:

Adding a VLAN only to the upstream switch does not attach it automatically to the UCS vNIC template. That response is associated with ucs vlan pool and template rather than the specific ucs mac pool uniqueness condition described here. For the stated failure, the preferred action is: Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment. Relevant evidence: Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables. Operations is validating the host before approving production workload placement.

B:

Two vNIC objects on the same failed upstream path do not provide true physical redundancy. This concerns UCS fabric redundancy, not UCS mac pool uniqueness.

C:

A high-priority label inside UCS does not guarantee every upstream switch honors that class. That response is associated with ucs network qos policy rather than the specific ucs mac pool uniqueness condition described here. For the stated failure, the preferred action is: Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment. Relevant evidence: Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables. Operations is validating the host before approving production workload placement.

Question 680

A new C-Series rack server powers on but its management controller cannot be reached from the secure operations subnet. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which evidence set most directly tests the suspected failure?

  1. Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding.
  2. Inspect applied boot policy, device enumeration, SAN LUN presentation and boot logs.
  3. Inspect CIMC settings, switchport VLAN, cabling, gateway and adjacent interface state.
  4. Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs.

Explanation

Correct Answer

C:

Inspect CIMC settings, switchport VLAN, cabling, gateway and adjacent interface state. These records help distinguish the suspected failure from a superficially similar fault before modifying production. The CIMC out-of-band interface requires correctly configured management connectivity independent of the installed server operating system. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding. This concerns UCS fabric redundancy, not UCS c-series cimc reachability.

B:

Inspect applied boot policy, device enumeration, SAN LUN presentation and boot logs. This concerns c-series boot policy alignment, not UCS c-series cimc reachability.

D:

Inspect IOM link state, chassis faults, discovery status and fabric interconnect logs. This concerns UCS blade chassis IOM discovery, not UCS c-series cimc reachability.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.