Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 59

Question 580

A fabric interconnect has never exported its current UCS configuration despite recent service-profile and policy changes. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which observations would best validate the initial diagnosis?

  1. Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding.
  2. Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables.
  3. Inspect effective vNIC templates, VLAN object assignments, LAN uplink trunk allowances and fault logs.
  4. Inspect backup type, completion logs, storage location, retention and access permissions.

Explanation

Correct Answer

D:

Inspect backup type, completion logs, storage location, retention and access permissions. These records help distinguish the suspected failure from a superficially similar fault before modifying production. UCS configuration backups retain recovery information for policies and identities and should accompany approved changes. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding. This concerns UCS fabric redundancy, not UCS management backup.

B:

Inspect MAC pool definitions, reservations, effective vNIC addresses and upstream MAC tables. This concerns UCS mac pool uniqueness, not UCS management backup.

C:

Inspect effective vNIC templates, VLAN object assignments, LAN uplink trunk allowances and fault logs. This concerns UCS VLAN pool and template, not UCS management backup.

Question 581

A fabric dashboard displays healthy switch reachability but a service experiences consistent high-latency paths. The team is preparing a controlled production change and must preserve fabric reachability. Which technical principle best explains the recommended response?

  1. With peer-link failure and a reachable peer, the secondary suspends vPC member ports to prevent loops and dual-active forwarding.
  2. RSTP prevents Layer 2 loops by assigning port roles and discarding redundant paths when necessary.
  3. LACP aggregates only compatible interfaces, and inconsistent operational settings can suspend members.
  4. Fabric assurance tools combine topology and operational observations but require data correlation to identify service causes.

Explanation

Correct Answer

D:

Fabric assurance tools combine topology and operational observations but require data correlation to identify service causes. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

With peer-link failure and a reachable peer, the secondary suspends vPC member ports to prevent loops and dual-active forwarding. This concerns vpc peer-link recovery, not nexus dashboard fabric visibility.

B:

RSTP prevents Layer 2 loops by assigning port roles and discarding redundant paths when necessary. This concerns rstp blocked uplink, not nexus dashboard fabric visibility.

C:

LACP aggregates only compatible interfaces, and inconsistent operational settings can suspend members. This concerns lacp member mismatch, not nexus dashboard fabric visibility.

Question 582

Two switches exchange frames over an untrusted fiber run, and security requirements call for link-layer encryption. A follow-up access review asks the team to validate the same boundary with a controlled negative test. What should the engineer collect before ruling out other causes?

  1. Inspect assigned user roles, AAA server attributes, command authorization and audit logs.
  2. Inspect source guard state, DHCP snooping bindings, static exceptions and ingress drop reasons.
  3. Inspect keychain definitions, active key lifetimes, authentication error logs and neighbor state.
  4. Inspect platform capability, MACsec session state, MKA status, cipher suite and protected traffic counters.

Explanation

Correct Answer

D:

Inspect platform capability, MACsec session state, MKA status, cipher suite and protected traffic counters. These records help distinguish the suspected failure from a superficially similar fault before modifying production. MACsec protects frames on a supported Ethernet link using negotiated encryption and integrity mechanisms. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

A:

Inspect assigned user roles, AAA server attributes, command authorization and audit logs. This concerns nx-os administrative RBAC, not MACsec protection scope.

B:

Inspect source guard state, DHCP snooping bindings, static exceptions and ingress drop reasons. This concerns first-hop ip/mac spoof defense, not MACsec protection scope.

C:

Inspect keychain definitions, active key lifetimes, authentication error logs and neighbor state. This concerns routing protocol keychain rollover, not MACsec protection scope.

Question 583

A server sees intermittent TCP resets, but an administrator only has coarse interface error counters. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What should the operator avoid assuming from the observed state?

  1. An oversubscribed SPAN destination can drop mirrored frames, so a capture is not necessarily complete.
  2. Editing the tenant's routing policy cannot fix an unattached physical-domain VLAN pool.
  3. Assigning an endpoint group cannot substitute for fabric-node discovery and registration.
  4. A unicast EVPN route alone does not ensure that every broadcast frame is replicated correctly.

Explanation

Correct Answer

A:

An oversubscribed SPAN destination can drop mirrored frames, so a capture is not necessarily complete. SPAN copies selected frames for packet inspection when protocol-level behavior is not visible in summarized counters. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

B:

Editing the tenant's routing policy cannot fix an unattached physical-domain VLAN pool. This concerns aci access policy chain, not span packet-level diagnosis.

C:

Assigning an endpoint group cannot substitute for fabric-node discovery and registration. This concerns aci fabric discovery, not span packet-level diagnosis.

D:

A unicast EVPN route alone does not ensure that every broadcast frame is replicated correctly. This concerns bum replication behavior, not span packet-level diagnosis.

Question 584

An operations team sees sporadic storage-path instability but its monitoring only polls device availability every five minutes. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which technical principle best explains the recommended response?

  1. The fabric name server reflects registered port identities and can reveal whether the expected target is visible.
  2. Configured zones and active enforced zoning can differ until the appropriate zoneset is activated.
  3. Device aliases map readable names to FC identifiers and must follow actual hardware identity changes.
  4. Topology, fabric events and time-series indicators reveal path problems hidden by simple reachability polling.

Explanation

Correct Answer

D:

Topology, fabric events and time-series indicators reveal path problems hidden by simple reachability polling. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

The fabric name server reflects registered port identities and can reveal whether the expected target is visible. This concerns fibre channel name-server entries, not nexus dashboard SAN monitoring.

B:

Configured zones and active enforced zoning can differ until the appropriate zoneset is activated. This concerns zoneset activation state, not nexus dashboard SAN monitoring.

C:

Device aliases map readable names to FC identifiers and must follow actual hardware identity changes. This concerns device alias maintenance, not nexus dashboard SAN monitoring.

Question 585

A maintenance script needs to run on a fixed schedule but an engineer proposes an EEM syslog trigger instead. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. Which controlled change is most appropriate given the evidence?

  1. Use NX-OS scheduling capability with the appropriate job definition and maintenance safeguards.
  2. Verify organization scope and referenced policy identifiers before retrying the profile creation.
  3. Validate the event detector pattern, applet registration and permitted action under the intended NX-OS context.
  4. Verify the Guest Shell environment, mounted paths and supported data-transfer method rather than assuming shared filesystems.

Explanation

Correct Answer

A:

Use NX-OS scheduling capability with the appropriate job definition and maintenance safeguards. Scheduled tasks follow time-based execution rather than requiring a spontaneous syslog event to fire. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.

Incorrect Answers

B:

Verify organization scope and referenced policy identifiers before retrying the profile creation. This concerns intersight policy automation, not nx-os scheduler jobs.

C:

Validate the event detector pattern, applet registration and permitted action under the intended NX-OS context. This concerns eem syslog-triggered remediation, not nx-os scheduler jobs.

D:

Verify the Guest Shell environment, mounted paths and supported data-transfer method rather than assuming shared filesystems. This concerns guest shell isolation, not nx-os scheduler jobs.

Question 586

A cloning operation for storage-connected service profiles risks assigning previously reserved WWPNs to replacement blades. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What is the strongest technical basis for the recommended action?

  1. UCS configuration backups retain recovery information for policies and identities and should accompany approved changes.
  2. A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur.
  3. SAN boot requires all of the initiator, fabric zoning, target presentation and boot policy to agree.
  4. Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably.

Explanation

Correct Answer

D:

Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

UCS configuration backups retain recovery information for policies and identities and should accompany approved changes. This concerns UCS management backup, not wwpn pool allocation.

B:

A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur. This concerns SAN connectivity from blade chassis, not wwpn pool allocation.

C:

SAN boot requires all of the initiator, fabric zoning, target presentation and boot policy to agree. This concerns SAN boot path policy, not wwpn pool allocation.

Question 587

A compromised endpoint sends frames with another host's IP address on the same access VLAN after DHCP snooping is enabled. Security engineering must restore the approved service without relaxing unrelated protection. What should the engineer collect before ruling out other causes?

  1. Inspect DHCP snooping trust configuration, VLAN enrollment, packet drops and server uplink topology.
  2. Inspect source guard state, DHCP snooping bindings, static exceptions and ingress drop reasons.
  3. Inspect keychain definitions, active key lifetimes, authentication error logs and neighbor state.
  4. Inspect role grants, resource-group associations, organization context and API access evidence.

Explanation

Correct Answer

B:

Inspect source guard state, DHCP snooping bindings, static exceptions and ingress drop reasons. These records help distinguish the suspected failure from a superficially similar fault before modifying production. IP source validation uses trusted bindings to prevent endpoints from impersonating unassigned source addresses. Security engineering must restore the approved service without relaxing unrelated protection.

Incorrect Answers

A:

Inspect DHCP snooping trust configuration, VLAN enrollment, packet drops and server uplink topology. That response is associated with dhcp snooping trusted uplink rather than the specific first-hop ip/mac spoof defense condition described here. For the stated failure, the preferred action is: Enforce an appropriate source-binding validation feature consistent with the recorded DHCP or static bindings. Relevant evidence: Inspect source guard state, DHCP snooping bindings, static exceptions and ingress drop reasons. Security engineering must restore the approved service without relaxing unrelated protection.

C:

Inspect keychain definitions, active key lifetimes, authentication error logs and neighbor state. That response is associated with routing protocol keychain rollover rather than the specific first-hop ip/mac spoof defense condition described here. For the stated failure, the preferred action is: Enforce an appropriate source-binding validation feature consistent with the recorded DHCP or static bindings. Relevant evidence: Inspect source guard state, DHCP snooping bindings, static exceptions and ingress drop reasons. Security engineering must restore the approved service without relaxing unrelated protection.

D:

Inspect role grants, resource-group associations, organization context and API access evidence. This concerns intersight scoped operations, not first-hop ip/mac spoof defense.

Question 588

A UCS blade chassis appears in inventory but several blades remain undiscovered after an I/O module replacement. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What should the engineer do first to address the observed failure?

  1. Compare the effective service profile boot policy with the physical and SAN targets visible to the server.
  2. Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs.
  3. Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities.
  4. Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path.

Explanation

Correct Answer

C:

Check fabric-interconnect connectivity, IOM state and chassis discovery before recreating server identities. The blade chassis depends on a healthy IOM and fabric-interconnect management path to discover and service blades. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Compare the effective service profile boot policy with the physical and SAN targets visible to the server. This concerns c-series boot policy alignment, not UCS blade chassis IOM discovery.

B:

Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs. This concerns UCS fabric redundancy, not UCS blade chassis IOM discovery.

D:

Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path. This concerns UCS VLAN pool and template, not UCS blade chassis IOM discovery.

Question 589

A design team labels a private on-premises cloud and a separately operated public cloud as one private deployment even though workloads move between them. The team is preparing a controlled production change and must preserve fabric reachability. Which limitation prevents the team from overgeneralizing this result?

  1. An oversubscribed SPAN destination can drop mirrored frames, so a capture is not necessarily complete.
  2. Sampled flow records may underrepresent small or short flows and do not contain every packet payload.
  3. Using a VPN between environments alone is not enough to prove application portability or cloud-service characteristics.
  4. Adding an EVPN route target cannot overcome a missing underlay IP path to the remote VTEP.

Explanation

Correct Answer

C:

Using a VPN between environments alone is not enough to prove application portability or cloud-service characteristics. Hybrid cloud combines distinct cloud infrastructures linked to support data and application portability. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

An oversubscribed SPAN destination can drop mirrored frames, so a capture is not necessarily complete. This concerns span packet-level diagnosis, not hybrid cloud model classification.

B:

Sampled flow records may underrepresent small or short flows and do not contain every packet payload. This concerns netflow traffic attribution, not hybrid cloud model classification.

D:

Adding an EVPN route target cannot overcome a missing underlay IP path to the remote VTEP. This concerns vxlan vtep underlay reachability, not hybrid cloud model classification.

Question 590

A compromised endpoint sends frames with another host's IP address on the same access VLAN after DHCP snooping is enabled. A follow-up access review asks the team to validate the same boundary with a controlled negative test. Which explanation most directly accounts for the required correction?

  1. IP source validation uses trusted bindings to prevent endpoints from impersonating unassigned source addresses.
  2. Routing-protocol authentication needs overlapping compatible keys during a planned rollover to preserve adjacency.
  3. Role-based access control limits administrators to the commands and resources needed for their work.
  4. DHCP snooping should accept DHCP server responses from trusted paths while suppressing rogue access-port servers.

Explanation

Correct Answer

A:

IP source validation uses trusted bindings to prevent endpoints from impersonating unassigned source addresses. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

B:

Routing-protocol authentication needs overlapping compatible keys during a planned rollover to preserve adjacency. This concerns routing protocol keychain rollover, not first-hop ip/mac spoof defense.

C:

Role-based access control limits administrators to the commands and resources needed for their work. This concerns nx-os administrative RBAC, not first-hop ip/mac spoof defense.

D:

DHCP snooping should accept DHCP server responses from trusted paths while suppressing rogue access-port servers. This concerns DHCP snooping trusted uplink, not first-hop ip/mac spoof defense.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.