Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 1

Question 1

A helpdesk operator needs to review UCS server faults but accidentally receives access to modify global SAN policies. A follow-up access review asks the team to validate the same boundary with a controlled negative test. What is the strongest technical basis for the recommended action?

  1. Fabric binding controls which fabric switches are allowed to join trusted SAN connections.
  2. Role-based access control limits administrators to the commands and resources needed for their work.
  3. Remote AAA improves centralized administration but must have an appropriate resilient recovery mechanism.
  4. Compute management RBAC should separate routine inspection from high-impact infrastructure changes.

Explanation

Correct Answer

D:

Compute management RBAC should separate routine inspection from high-impact infrastructure changes. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

A:

Fabric binding controls which fabric switches are allowed to join trusted SAN connections. This concerns fabric binding membership, not UCS administrative separation.

B:

Role-based access control limits administrators to the commands and resources needed for their work. This concerns nx-os administrative RBAC, not UCS administrative separation.

C:

Remote AAA improves centralized administration but must have an appropriate resilient recovery mechanism. This concerns centralized AAA fallback, not UCS administrative separation.

Question 2

A helpdesk operator needs to review UCS server faults but accidentally receives access to modify global SAN policies. Security engineering must restore the approved service without relaxing unrelated protection. What should the engineer do first to address the observed failure?

  1. Configure and test the approved AAA method order and protected break-glass account following change policy.
  2. Assign a restricted read-only RBAC role covering the required monitoring commands.
  3. Assign a scoped UCS administrative role that permits health visibility without SAN policy modification.
  4. Apply and validate a narrowly scoped ACI contract with the required provider-consumer relationship and filters.

Explanation

Correct Answer

C:

Assign a scoped UCS administrative role that permits health visibility without SAN policy modification. Compute management RBAC should separate routine inspection from high-impact infrastructure changes. Security engineering must restore the approved service without relaxing unrelated protection.

Incorrect Answers

A:

Configure and test the approved AAA method order and protected break-glass account following change policy. This concerns centralized AAA fallback, not UCS administrative separation.

B:

Assign a restricted read-only RBAC role covering the required monitoring commands. This concerns nx-os administrative RBAC, not UCS administrative separation.

D:

Apply and validate a narrowly scoped ACI contract with the required provider-consumer relationship and filters. This concerns aci inter-epg contract, not UCS administrative separation.

Question 3

Two production Nexus peers have drifted in their intended interface templates after unreviewed local commands were applied. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which technical principle best explains the recommended response?

  1. Configuration management detects and remediates unauthorized deviations rather than trusting the most recent device state.
  2. SPAN copies selected frames for packet inspection when protocol-level behavior is not visible in summarized counters.
  3. Nondisruptive software upgrade support is platform, topology and image-path dependent and must be verified.
  4. Flow records expose traffic conversations and volume patterns that interface-level totals cannot distinguish.

Explanation

Correct Answer

A:

Configuration management detects and remediates unauthorized deviations rather than trusting the most recent device state. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

B:

SPAN copies selected frames for packet inspection when protocol-level behavior is not visible in summarized counters. This concerns span packet-level diagnosis, not fabric configuration drift.

C:

Nondisruptive software upgrade support is platform, topology and image-path dependent and must be verified. This concerns nexus issu eligibility, not fabric configuration drift.

D:

Flow records expose traffic conversations and volume patterns that interface-level totals cannot distinguish. This concerns netflow traffic attribution, not fabric configuration drift.

Question 4

A compromised endpoint sends frames with another host's IP address on the same access VLAN after DHCP snooping is enabled. A follow-up access review asks the team to validate the same boundary with a controlled negative test. Which intervention most directly addresses the stated condition?

  1. Enforce an appropriate source-binding validation feature consistent with the recorded DHCP or static bindings.
  2. Validate DAI binding sources and configure a supported static ARP ACL or binding for the approved fixed-address hosts.
  3. Mark only the verified DHCP-server-facing interface as trusted and validate the snooping VLAN scope.
  4. Coordinate authentication key IDs, algorithms and valid lifetimes across both peers before retiring the old key.

Explanation

Correct Answer

A:

Enforce an appropriate source-binding validation feature consistent with the recorded DHCP or static bindings. IP source validation uses trusted bindings to prevent endpoints from impersonating unassigned source addresses. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

B:

Validate DAI binding sources and configure a supported static ARP ACL or binding for the approved fixed-address hosts. This concerns dynamic ARP inspection source of truth, not first-hop ip/mac spoof defense.

C:

Mark only the verified DHCP-server-facing interface as trusted and validate the snooping VLAN scope. This concerns DHCP snooping trusted uplink, not first-hop ip/mac spoof defense.

D:

Coordinate authentication key IDs, algorithms and valid lifetimes across both peers before retiring the old key. This concerns routing protocol keychain rollover, not first-hop ip/mac spoof defense.

Question 5

An MDS operator edits the configured zoneset but a host still cannot discover the newly authorized storage target. A storage change board requires a traceable diagnosis before allowing further fabric changes. What information should be inspected before the change is applied?

  1. Inspect FCNS database, FLOGI records, target WWPN, VSAN association and port transition logs.
  2. Inspect active zone members, initiator WWPNs, target WWPNs and intended host-to-LUN access matrices.
  3. Inspect active zoneset, configured zoneset, VSAN ID and activation history.
  4. Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples.

Explanation

Correct Answer

C:

Inspect active zoneset, configured zoneset, VSAN ID and activation history. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Configured zones and active enforced zoning can differ until the appropriate zoneset is activated. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Inspect FCNS database, FLOGI records, target WWPN, VSAN association and port transition logs. That response is associated with fibre channel name-server entries rather than the specific zoneset activation state condition described here. For the stated failure, the preferred action is: Activate the intended zoneset on the correct VSAN and validate its active membership. Relevant evidence: Inspect active zoneset, configured zoneset, VSAN ID and activation history. A storage change board requires a traceable diagnosis before allowing further fabric changes.

B:

Inspect active zone members, initiator WWPNs, target WWPNs and intended host-to-LUN access matrices. That response is associated with single-initiator zoning rather than the specific zoneset activation state condition described here. For the stated failure, the preferred action is: Activate the intended zoneset on the correct VSAN and validate its active membership. Relevant evidence: Inspect active zoneset, configured zoneset, VSAN ID and activation history. A storage change board requires a traceable diagnosis before allowing further fabric changes.

D:

Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples. This concerns SAN port error telemetry, not zoneset activation state.

Question 6

A Linux utility installed in the NX-OS Guest Shell cannot find a file that an operator placed on a different management workstation. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. What should the engineer collect before ruling out other causes?

  1. Inspect EEM detector configuration, actual syslog message, applet history and action permissions.
  2. Inspect job definition, scheduler timetable, execution status and change-window policy.
  3. Inspect Guest Shell availability, mount mappings, file locations, network access and executed command output.
  4. Inspect response status and body, user roles, NX-API feature state and endpoint documentation.

Explanation

Correct Answer

C:

Inspect Guest Shell availability, mount mappings, file locations, network access and executed command output. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Guest Shell provides a separate Linux execution environment with its own file and permission context. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.

Incorrect Answers

A:

Inspect EEM detector configuration, actual syslog message, applet history and action permissions. This concerns eem syslog-triggered remediation, not guest shell isolation.

B:

Inspect job definition, scheduler timetable, execution status and change-window policy. This concerns nx-os scheduler jobs, not guest shell isolation.

D:

Inspect response status and body, user roles, NX-API feature state and endpoint documentation. This concerns nx-api request authorization, not guest shell isolation.

Question 7

A GPU training cluster reports reduced throughput when synchronized east-west traffic converges on a few uplinks despite healthy compute nodes. The automation change must pass a preproduction test and leave a verifiable audit trail. Which result would best confirm that the remediation worked?

  1. Tests with absent fields return an explicit unknown/error outcome rather than a fabricated healthy metric.
  2. The network change reduces packet loss and congestion while measured training-step throughput improves.
  3. A second run against an unchanged fabric reports no material differences and service tests remain stable.
  4. A simulated timeout followed by retry yields one intended resource and a documented final state.

Explanation

Correct Answer

B:

The network change reduces packet loss and congestion while measured training-step throughput improves. This result tests the original failure rather than reporting merely that the configuration command was accepted. Distributed AI jobs can be bottlenecked by data-center fabric transport when many nodes exchange bursts of data. The automation change must pass a preproduction test and leave a verifiable audit trail.

Incorrect Answers

A:

Tests with absent fields return an explicit unknown/error outcome rather than a fabricated healthy metric. This concerns on-box python exception handling, not ai cluster network congestion.

C:

A second run against an unchanged fabric reports no material differences and service tests remain stable. This concerns ansible idempotent templates, not ai cluster network congestion.

D:

A simulated timeout followed by retry yields one intended resource and a documented final state. This concerns rest api retries and idempotence, not ai cluster network congestion.

Question 8

A SAN array replaces a target HBA but operators try to keep its old WWPN hidden behind the same device alias without verification. A storage change board requires a traceable diagnosis before allowing further fabric changes. What should the operator avoid assuming from the observed state?

  1. A friendly alias name is not a substitute for a correct underlying port WWPN.
  2. An old name-server entry for the former target port does not prove the replacement path is live.
  3. Saving a zoneset definition alone does not establish that it is the enforced active zoning policy.
  4. Turning on NPV alone does not create initiator logins if upstream NPIV is unavailable.

Explanation

Correct Answer

A:

A friendly alias name is not a substitute for a correct underlying port WWPN. Device aliases map readable names to FC identifiers and must follow actual hardware identity changes. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

B:

An old name-server entry for the former target port does not prove the replacement path is live. That response is associated with fibre channel name-server entries rather than the specific device alias maintenance condition described here. For the stated failure, the preferred action is: Update the device alias to the authorized new WWPN and validate all zoning references before applying it. Relevant evidence: Inspect alias database, recorded target WWPNs, zones using the alias and change approvals. A storage change board requires a traceable diagnosis before allowing further fabric changes.

C:

Saving a zoneset definition alone does not establish that it is the enforced active zoning policy. This concerns zoneset activation state, not device alias maintenance.

D:

Turning on NPV alone does not create initiator logins if upstream NPIV is unavailable. That response is associated with npv uplink fabric services rather than the specific device alias maintenance condition described here. For the stated failure, the preferred action is: Update the device alias to the authorized new WWPN and validate all zoning references before applying it. Relevant evidence: Inspect alias database, recorded target WWPNs, zones using the alias and change approvals. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Question 9

A design team labels a private on-premises cloud and a separately operated public cloud as one private deployment even though workloads move between them. The team is preparing a controlled production change and must preserve fabric reachability. What is the best next implementation or troubleshooting step?

  1. Schedule EPLD maintenance using platform-specific impact guidance and verified redundancy coverage.
  2. Compare actual configuration to a version-controlled golden baseline and restore approved differences through change control.
  3. Classify the architecture using the NIST deployment definitions and document the interaction between distinct cloud infrastructures.
  4. Validate the VNI's BUM replication configuration and peer membership before changing unicast forwarding.

Explanation

Correct Answer

C:

Classify the architecture using the NIST deployment definitions and document the interaction between distinct cloud infrastructures. Hybrid cloud combines distinct cloud infrastructures linked to support data and application portability. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

Schedule EPLD maintenance using platform-specific impact guidance and verified redundancy coverage. This concerns epld firmware maintenance, not hybrid cloud model classification.

B:

Compare actual configuration to a version-controlled golden baseline and restore approved differences through change control. This concerns fabric configuration drift, not hybrid cloud model classification.

D:

Validate the VNI's BUM replication configuration and peer membership before changing unicast forwarding. This concerns bum replication behavior, not hybrid cloud model classification.

Question 10

Updating a UCS updating-template appears to change vNIC settings on more blades than intended. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which controlled change is most appropriate given the evidence?

  1. Restore the intended production boot-device order and detach temporary install media from the active policy.
  2. Inspect chassis power, fan and thermal faults before changing application performance settings.
  3. Stage and review the template relationship and scope before applying an impactful shared-policy change.
  4. Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies.

Explanation

Correct Answer

C:

Stage and review the template relationship and scope before applying an impactful shared-policy change. Updating templates can propagate modifications to associated service profiles; change impact depends on associations. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Restore the intended production boot-device order and detach temporary install media from the active policy. This concerns boot order and removable media, not updating service-profile templates.

B:

Inspect chassis power, fan and thermal faults before changing application performance settings. This concerns chassis power and thermal monitoring, not updating service-profile templates.

D:

Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies. This concerns server pool qualification, not updating service-profile templates.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.