Question 870
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A small business wants staff and guest Wi-Fi to share one physical switch without sharing the same broadcast domain. Two departments are placed in different VLANs and an engineer assumes users can freely communicate without a router or Layer 3 switch. Which response best addresses these needs?
- Use the company's supported VPN client and verify authentication and tunnel policy; Provide controlled inter-VLAN routing only where access policy permits the traffic.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; check the VPN-provided DNS suffix and resolver settings before altering the server firewall.
- Use the company's supported VPN client and verify authentication and tunnel policy; check the VPN-provided DNS suffix and resolver settings before altering the server firewall.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; Provide controlled inter-VLAN routing only where access policy permits the traffic.
Explanation
Correct Answer
D:For ticket (1), VLAN tagging divides a switched network into separate Layer 2 broadcast domains. For ticket (2), Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries.
Incorrect Answers
A:For ticket 1, configure separate VLANs with explicit router/firewall rules between the logical networks. VLAN tagging divides a switched network into separate Layer 2 broadcast domains.
B:For ticket 2, provide controlled inter-VLAN routing only where access policy permits the traffic. Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries.
C:For ticket 1, configure separate VLANs with explicit router/firewall rules between the logical networks. VLAN tagging divides a switched network into separate Layer 2 broadcast domains. For ticket 2, provide controlled inter-VLAN routing only where access policy permits the traffic. Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries.
Question 871
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A home-office employee needs encrypted access to authorized internal corporate resources over a public internet connection. A VPN user can reach a corporate server by IP but not by short hostname after establishing the tunnel. What is the most appropriate plan for this situation?
- Configure separate VLANs with explicit router/firewall rules between the logical networks; check the VPN-provided DNS suffix and resolver settings before altering the server firewall.
- Use the company's supported VPN client and verify authentication and tunnel policy; Provide controlled inter-VLAN routing only where access policy permits the traffic.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; Provide controlled inter-VLAN routing only where access policy permits the traffic.
- Use the company's supported VPN client and verify authentication and tunnel policy; check the VPN-provided DNS suffix and resolver settings before altering the server firewall.
Explanation
Correct Answer
D:For ticket (1), VPN tunneling protects approved remote traffic across untrusted intermediary networks. For ticket (2), Remote tunnels may connect successfully while still using inappropriate local DNS lookup settings.
Incorrect Answers
A:For ticket 1, use the company's supported VPN client and verify authentication and tunnel policy. VPN tunneling protects approved remote traffic across untrusted intermediary networks.
B:For ticket 2, check the VPN-provided DNS suffix and resolver settings before altering the server firewall. Remote tunnels may connect successfully while still using inappropriate local DNS lookup settings.
C:For ticket 1, use the company's supported VPN client and verify authentication and tunnel policy. VPN tunneling protects approved remote traffic across untrusted intermediary networks. For ticket 2, check the VPN-provided DNS suffix and resolver settings before altering the server firewall. Remote tunnels may connect successfully while still using inappropriate local DNS lookup settings.
Question 872
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: Two departments are placed in different VLANs and an engineer assumes users can freely communicate without a router or Layer 3 switch. A VPN user can reach a corporate server by IP but not by short hostname after establishing the tunnel. Which course of action addresses the stated issues?
- Provide controlled inter-VLAN routing only where access policy permits the traffic; check the VPN-provided DNS suffix and resolver settings before altering the server firewall.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; check the VPN-provided DNS suffix and resolver settings before altering the server firewall.
- Provide controlled inter-VLAN routing only where access policy permits the traffic; use the company's supported VPN client and verify authentication and tunnel policy.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; use the company's supported VPN client and verify authentication and tunnel policy.
Explanation
Correct Answer
A:For ticket (1), Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries. For ticket (2), Remote tunnels may connect successfully while still using inappropriate local DNS lookup settings.
Incorrect Answers
B:For ticket 1, provide controlled inter-VLAN routing only where access policy permits the traffic. Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries.
C:For ticket 2, check the VPN-provided DNS suffix and resolver settings before altering the server firewall. Remote tunnels may connect successfully while still using inappropriate local DNS lookup settings.
D:For ticket 1, provide controlled inter-VLAN routing only where access policy permits the traffic. Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries. For ticket 2, check the VPN-provided DNS suffix and resolver settings before altering the server firewall. Remote tunnels may connect successfully while still using inappropriate local DNS lookup settings.
Question 873
A service coordinator has THREE separate support tickets and needs the correct matching actions: A small business wants staff and guest Wi-Fi to share one physical switch without sharing the same broadcast domain. A home-office employee needs encrypted access to authorized internal corporate resources over a public internet connection. Two departments are placed in different VLANs and an engineer assumes users can freely communicate without a router or Layer 3 switch. Which response best addresses these needs?
- Check the VPN-provided DNS suffix and resolver settings before altering the server firewall; use the company's supported VPN client and verify authentication and tunnel policy; and Provide controlled inter-VLAN routing only where access policy permits the traffic.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; check the VPN-provided DNS suffix and resolver settings before altering the server firewall; and Provide controlled inter-VLAN routing only where access policy permits the traffic.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; use the company's supported VPN client and verify authentication and tunnel policy; and check the VPN-provided DNS suffix and resolver settings before altering the server firewall.
- Configure separate VLANs with explicit router/firewall rules between the logical networks; use the company's supported VPN client and verify authentication and tunnel policy; and Provide controlled inter-VLAN routing only where access policy permits the traffic.
Explanation
Correct Answer
D:For ticket (1), VLAN tagging divides a switched network into separate Layer 2 broadcast domains. For ticket (2), VPN tunneling protects approved remote traffic across untrusted intermediary networks. For ticket (3), Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries.
Incorrect Answers
A:For ticket 1, configure separate VLANs with explicit router/firewall rules between the logical networks. VLAN tagging divides a switched network into separate Layer 2 broadcast domains.
B:For ticket 2, use the company's supported VPN client and verify authentication and tunnel policy. VPN tunneling protects approved remote traffic across untrusted intermediary networks.
C:For ticket 3, provide controlled inter-VLAN routing only where access policy permits the traffic. Separate VLANs require Layer 3 forwarding and policy for communications across subnet boundaries.
Question 874
A field technician verifies the following customer equipment condition: A desktop hard drive emits repeating clicking sounds and files become intermittently unreadable during ordinary access. Which response BEST addresses the actual cause or requirement?
- Restore the correct SATA power connection and recheck drive detection.
- Verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Replace the suspect cable or connector and confirm stable operation before condemning the drive.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery.
Explanation
Correct Answer
D:Repeated mechanical clicks and read errors are warning signs of possible head or media failure.
Incorrect Answers
A:Restoring the correct SATA power connection and recheck drive detection would not stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery.
B:Verifying data protection and planning proactive disk replacement rather than ignore the health trend would not stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery.
C:Replacing the suspect cable or connector and confirming stable operation would not stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery.
Question 875
An IT support worker is asked to resolve this case: An internal HDD is absent from firmware after a PC is moved, but the technician finds its SATA power cable disconnected. Which next step MOST directly resolves the reported condition?
- Restore the correct SATA power connection and recheck drive detection.
- Verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Replace the suspect cable or connector and confirm stable operation before condemning the drive.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery.
Explanation
Correct Answer
A:A storage device without electrical power cannot enumerate even with a healthy data cable.
Incorrect Answers
B:Verifying data protection and planning proactive disk replacement rather than ignore the health trend would not restore the correct SATA power connection and recheck drive detection.
C:Replacing the suspect cable or connector and confirming stable operation would not restore the correct SATA power connection and recheck drive detection.
D:Stopping unnecessary writes, protect recoverable data and replacing the failing drive after safe backup or recovery would not restore the correct SATA power connection and recheck drive detection.
Question 876
A service bench observes this hardware or network symptom: A spinning hard drive reports growing SMART reallocated sectors and increasing uncorrectable errors across successive checks. What should the support specialist recommend FIRST within the stated limits?
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery.
- Restore the correct SATA power connection and recheck drive detection.
- Verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Replace the suspect cable or connector and confirm stable operation before condemning the drive.
Explanation
Correct Answer
C:Increasing media errors can indicate degradation before complete drive failure.
Incorrect Answers
A:Stopping unnecessary writes, protect recoverable data and replacing the failing drive after safe backup or recovery would not verify data protection and plan proactive disk replacement rather than ignore the health trend.
B:Restoring the correct SATA power connection and recheck drive detection would not verify data protection and plan proactive disk replacement rather than ignore the health trend.
D:Replacing the suspect cable or connector and confirming stable operation would not verify data protection and plan proactive disk replacement rather than ignore the health trend.
Question 877
During a controlled office IT maintenance window, the technician notes: A portable disk repeatedly disconnects only when attached through a loose external USB cable while its health data looks normal. What is the MOST appropriate technician action?
- Verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Replace the suspect cable or connector and confirm stable operation before condemning the drive.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery.
- Restore the correct SATA power connection and recheck drive detection.
Explanation
Correct Answer
B:Transport errors from intermittent cabling can imitate storage failure.
Incorrect Answers
A:Verifying data protection and planning proactive disk replacement rather than ignore the health trend would not replace the suspect cable or connector and confirm stable operation.
C:Stopping unnecessary writes, protect recoverable data and replacing the failing drive after safe backup or recovery would not replace the suspect cable or connector and confirm stable operation.
D:Restoring the correct SATA power connection and recheck drive detection would not replace the suspect cable or connector and confirm stable operation.
Question 878
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A desktop hard drive emits repeating clicking sounds and files become intermittently unreadable during ordinary access. An internal HDD is absent from firmware after a PC is moved, but the technician finds its SATA power cable disconnected. Which course of action addresses the stated issues?
- Verify data protection and plan proactive disk replacement rather than ignore the health trend; restore the correct SATA power connection and recheck drive detection.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery; replace the suspect cable or connector and confirm stable operation before condemning the drive.
- Verify data protection and plan proactive disk replacement rather than ignore the health trend; replace the suspect cable or connector and confirm stable operation before condemning the drive.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery; restore the correct SATA power connection and recheck drive detection.
Explanation
Correct Answer
D:For ticket (1), Repeated mechanical clicks and read errors are warning signs of possible head or media failure. For ticket (2), A storage device without electrical power cannot enumerate even with a healthy data cable.
Incorrect Answers
A:For ticket 1, stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery. Repeated mechanical clicks and read errors are warning signs of possible head or media failure.
B:For ticket 2, restore the correct SATA power connection and recheck drive detection. A storage device without electrical power cannot enumerate even with a healthy data cable.
C:For ticket 1, stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery. Repeated mechanical clicks and read errors are warning signs of possible head or media failure. For ticket 2, restore the correct SATA power connection and recheck drive detection. A storage device without electrical power cannot enumerate even with a healthy data cable.
Question 879
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A desktop hard drive emits repeating clicking sounds and files become intermittently unreadable during ordinary access. A spinning hard drive reports growing SMART reallocated sectors and increasing uncorrectable errors across successive checks. Which response best addresses these needs?
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery; verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Restore the correct SATA power connection and recheck drive detection; verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery; replace the suspect cable or connector and confirm stable operation before condemning the drive.
- Restore the correct SATA power connection and recheck drive detection; replace the suspect cable or connector and confirm stable operation before condemning the drive.
Explanation
Correct Answer
A:For ticket (1), Repeated mechanical clicks and read errors are warning signs of possible head or media failure. For ticket (2), Increasing media errors can indicate degradation before complete drive failure.
Incorrect Answers
B:For ticket 1, stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery. Repeated mechanical clicks and read errors are warning signs of possible head or media failure.
C:For ticket 2, verify data protection and plan proactive disk replacement rather than ignore the health trend. Increasing media errors can indicate degradation before complete drive failure.
D:For ticket 1, stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery. Repeated mechanical clicks and read errors are warning signs of possible head or media failure. For ticket 2, verify data protection and plan proactive disk replacement rather than ignore the health trend. Increasing media errors can indicate degradation before complete drive failure.
Question 880
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: An internal HDD is absent from firmware after a PC is moved, but the technician finds its SATA power cable disconnected. A portable disk repeatedly disconnects only when attached through a loose external USB cable while its health data looks normal. What is the most appropriate plan for this situation?
- Restore the correct SATA power connection and recheck drive detection; verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery; verify data protection and plan proactive disk replacement rather than ignore the health trend.
- Restore the correct SATA power connection and recheck drive detection; replace the suspect cable or connector and confirm stable operation before condemning the drive.
- Stop unnecessary writes, protect recoverable data and replace the failing drive after safe backup or recovery; replace the suspect cable or connector and confirm stable operation before condemning the drive.
Explanation
Correct Answer
C:For ticket (1), A storage device without electrical power cannot enumerate even with a healthy data cable. For ticket (2), Transport errors from intermittent cabling can imitate storage failure.
Incorrect Answers
A:For ticket 2, replace the suspect cable or connector and confirm stable operation before condemning the drive. Transport errors from intermittent cabling can imitate storage failure.
B:For ticket 1, restore the correct SATA power connection and recheck drive detection. A storage device without electrical power cannot enumerate even with a healthy data cable. For ticket 2, replace the suspect cable or connector and confirm stable operation before condemning the drive. Transport errors from intermittent cabling can imitate storage failure.
D:For ticket 1, restore the correct SATA power connection and recheck drive detection. A storage device without electrical power cannot enumerate even with a healthy data cable.
CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests