Question 690
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A RAID 1 controller reports a degraded mirror after one physical disk failed, but the surviving member remains accessible. A RAID 6 set shows two failed members and a third disk develops errors during attempted rebuild. Which response best addresses these needs?
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; restore data from an independent backup, because RAID 0 has no redundancy.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly; restore data from an independent backup, because RAID 0 has no redundancy.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly; prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
Explanation
Correct Answer
C:For ticket (1), Mirroring can maintain availability after one failed disk while redundancy must be restored. For ticket (2), Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
Incorrect Answers
A:For ticket 2, prioritize protected recovery and validated backups rather than assume the array can survive a third failure. Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
B:For ticket 1, replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan. Mirroring can maintain availability after one failed disk while redundancy must be restored. For ticket 2, prioritize protected recovery and validated backups rather than assume the array can survive a third failure. Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
D:For ticket 1, replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan. Mirroring can maintain availability after one failed disk while redundancy must be restored.
Question 691
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A RAID 5 array already has one failed drive and an operator plans to remove a second drive while users still need data. A technician believes a RAID 0 striped volume can be rebuilt from one surviving disk after the other has failed. What is the most appropriate plan for this situation?
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; restore data from an independent backup, because RAID 0 has no redundancy.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly; prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly; restore data from an independent backup, because RAID 0 has no redundancy.
Explanation
Correct Answer
D:For ticket (1), Traditional RAID 5 cannot tolerate two simultaneous member-drive failures. For ticket (2), Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency.
Incorrect Answers
A:For ticket 1, avoid additional member removal and follow the controller-supported recovery procedure promptly. Traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
B:For ticket 2, restore data from an independent backup, because RAID 0 has no redundancy. Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency.
C:For ticket 1, avoid additional member removal and follow the controller-supported recovery procedure promptly. Traditional RAID 5 cannot tolerate two simultaneous member-drive failures. For ticket 2, restore data from an independent backup, because RAID 0 has no redundancy. Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency.
Question 692
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A RAID 6 set shows two failed members and a third disk develops errors during attempted rebuild. A technician believes a RAID 0 striped volume can be rebuilt from one surviving disk after the other has failed. Which course of action addresses the stated issues?
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; Avoid additional member removal and follow the controller-supported recovery procedure promptly.
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure; restore data from an independent backup, because RAID 0 has no redundancy.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; restore data from an independent backup, because RAID 0 has no redundancy.
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure; Avoid additional member removal and follow the controller-supported recovery procedure promptly.
Explanation
Correct Answer
B:For ticket (1), Dual parity tolerates at most two failed members under normal RAID 6 assumptions. For ticket (2), Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency.
Incorrect Answers
A:For ticket 1, prioritize protected recovery and validated backups rather than assume the array can survive a third failure. Dual parity tolerates at most two failed members under normal RAID 6 assumptions. For ticket 2, restore data from an independent backup, because RAID 0 has no redundancy. Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency.
C:For ticket 1, prioritize protected recovery and validated backups rather than assume the array can survive a third failure. Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
D:For ticket 2, restore data from an independent backup, because RAID 0 has no redundancy. Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency.
Question 693
A service coordinator has THREE separate support tickets and needs the correct matching actions: A RAID 1 controller reports a degraded mirror after one physical disk failed, but the surviving member remains accessible. A RAID 5 array already has one failed drive and an operator plans to remove a second drive while users still need data. A RAID 6 set shows two failed members and a third disk develops errors during attempted rebuild. Which response best addresses these needs?
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; restore data from an independent backup, because RAID 0 has no redundancy; and prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; Avoid additional member removal and follow the controller-supported recovery procedure promptly; and restore data from an independent backup, because RAID 0 has no redundancy.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; Avoid additional member removal and follow the controller-supported recovery procedure promptly; and prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Restore data from an independent backup, because RAID 0 has no redundancy; Avoid additional member removal and follow the controller-supported recovery procedure promptly; and prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
Explanation
Correct Answer
C:For ticket (1), Mirroring can maintain availability after one failed disk while redundancy must be restored. For ticket (2), Traditional RAID 5 cannot tolerate two simultaneous member-drive failures. For ticket (3), Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
Incorrect Answers
A:For ticket 2, avoid additional member removal and follow the controller-supported recovery procedure promptly. Traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
B:For ticket 3, prioritize protected recovery and validated backups rather than assume the array can survive a third failure. Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
D:For ticket 1, replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan. Mirroring can maintain availability after one failed disk while redundancy must be restored.
Question 694
A support case documents the following situation: A technician wires one end of an Ethernet patch cable using T568A and the other using T568B despite a straight-through cabling requirement. Which response BEST addresses the actual cause or requirement?
- Use appropriately rated plenum cable where required by applicable building codes.
- Select supported shielded twisted-pair cable and install grounding according to its specifications.
- Choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Terminate both ends to the same selected T568 standard and verify the pinout.
Explanation
Correct Answer
D:Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection.
Incorrect Answers
A:Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces; mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection.
B:Shielded cabling can reduce interference but requires correct system design and termination; mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection.
C:Indoor jackets and connectors may degrade with moisture and environmental exposure; mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection.
Question 695
A device support specialist must respond to this request: A network closet runs copper through an air-handling ceiling and the installer chooses an ordinary jacket without reviewing building requirements. Which next step MOST directly resolves the reported condition?
- Choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Terminate both ends to the same selected T568 standard and verify the pinout.
- Use appropriately rated plenum cable where required by applicable building codes.
- Select supported shielded twisted-pair cable and install grounding according to its specifications.
Explanation
Correct Answer
C:Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
Incorrect Answers
A:Indoor jackets and connectors may degrade with moisture and environmental exposure; plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
B:Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection; plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
D:Shielded cabling can reduce interference but requires correct system design and termination; plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
Question 696
An end user reports the following condition: An electrical room produces electromagnetic interference, and a designer proposes unshielded cabling despite the site survey calling for shielding. What should the support specialist recommend FIRST within the stated limits?
- Use appropriately rated plenum cable where required by applicable building codes.
- Select supported shielded twisted-pair cable and install grounding according to its specifications.
- Choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Terminate both ends to the same selected T568 standard and verify the pinout.
Explanation
Correct Answer
B:Shielded cabling can reduce interference but requires correct system design and termination.
Incorrect Answers
A:Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces; shielded cabling can reduce interference but requires correct system design and termination.
C:Indoor jackets and connectors may degrade with moisture and environmental exposure; shielded cabling can reduce interference but requires correct system design and termination.
D:Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection; shielded cabling can reduce interference but requires correct system design and termination.
Question 697
A help desk receives a support ticket with this evidence: A long-distance buried Ethernet run is proposed using ordinary indoor patch cable directly in wet soil. What is the MOST appropriate technician action?
- Choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Terminate both ends to the same selected T568 standard and verify the pinout.
- Use appropriately rated plenum cable where required by applicable building codes.
- Select supported shielded twisted-pair cable and install grounding according to its specifications.
Explanation
Correct Answer
A:Indoor jackets and connectors may degrade with moisture and environmental exposure.
Incorrect Answers
B:Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection; indoor jackets and connectors may degrade with moisture and environmental exposure.
C:Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces; indoor jackets and connectors may degrade with moisture and environmental exposure.
D:Shielded cabling can reduce interference but requires correct system design and termination; indoor jackets and connectors may degrade with moisture and environmental exposure.
Question 698
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A technician wires one end of an Ethernet patch cable using T568A and the other using T568B despite a straight-through cabling requirement. A network closet runs copper through an air-handling ceiling and the installer chooses an ordinary jacket without reviewing building requirements. Which course of action addresses the stated issues?
- Select supported shielded twisted-pair cable and install grounding according to its specifications; choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Terminate both ends to the same selected T568 standard and verify the pinout; use appropriately rated plenum cable where required by applicable building codes.
- Select supported shielded twisted-pair cable and install grounding according to its specifications; use appropriately rated plenum cable where required by applicable building codes.
- Terminate both ends to the same selected T568 standard and verify the pinout; choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
Explanation
Correct Answer
B:For ticket (1), Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection. For ticket (2), Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
Incorrect Answers
A:For ticket 1, terminate both ends to the same selected T568 standard and verify the pinout. Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection. For ticket 2, use appropriately rated plenum cable where required by applicable building codes. Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
C:For ticket 1, terminate both ends to the same selected T568 standard and verify the pinout. Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection.
D:For ticket 2, use appropriately rated plenum cable where required by applicable building codes. Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
Question 699
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A technician wires one end of an Ethernet patch cable using T568A and the other using T568B despite a straight-through cabling requirement. An electrical room produces electromagnetic interference, and a designer proposes unshielded cabling despite the site survey calling for shielding. Which response best addresses these needs?
- Use appropriately rated plenum cable where required by applicable building codes; select supported shielded twisted-pair cable and install grounding according to its specifications.
- Terminate both ends to the same selected T568 standard and verify the pinout; choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Use appropriately rated plenum cable where required by applicable building codes; choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Terminate both ends to the same selected T568 standard and verify the pinout; select supported shielded twisted-pair cable and install grounding according to its specifications.
Explanation
Correct Answer
D:For ticket (1), Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection. For ticket (2), Shielded cabling can reduce interference but requires correct system design and termination.
Incorrect Answers
A:For ticket 1, terminate both ends to the same selected T568 standard and verify the pinout. Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection.
B:For ticket 2, select supported shielded twisted-pair cable and install grounding according to its specifications. Shielded cabling can reduce interference but requires correct system design and termination.
C:For ticket 1, terminate both ends to the same selected T568 standard and verify the pinout. Mixed T568A/T568B ends form a crossover pattern rather than a straight-through connection. For ticket 2, select supported shielded twisted-pair cable and install grounding according to its specifications. Shielded cabling can reduce interference but requires correct system design and termination.
Question 700
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A network closet runs copper through an air-handling ceiling and the installer chooses an ordinary jacket without reviewing building requirements. A long-distance buried Ethernet run is proposed using ordinary indoor patch cable directly in wet soil. What is the most appropriate plan for this situation?
- Use appropriately rated plenum cable where required by applicable building codes; select supported shielded twisted-pair cable and install grounding according to its specifications.
- Terminate both ends to the same selected T568 standard and verify the pinout; select supported shielded twisted-pair cable and install grounding according to its specifications.
- Use appropriately rated plenum cable where required by applicable building codes; choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
- Terminate both ends to the same selected T568 standard and verify the pinout; choose an outdoor/direct-burial-rated cable or an appropriate protected medium.
Explanation
Correct Answer
C:For ticket (1), Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces. For ticket (2), Indoor jackets and connectors may degrade with moisture and environmental exposure.
Incorrect Answers
A:For ticket 2, choose an outdoor/direct-burial-rated cable or an appropriate protected medium. Indoor jackets and connectors may degrade with moisture and environmental exposure.
B:For ticket 1, use appropriately rated plenum cable where required by applicable building codes. Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces. For ticket 2, choose an outdoor/direct-burial-rated cable or an appropriate protected medium. Indoor jackets and connectors may degrade with moisture and environmental exposure.
D:For ticket 1, use appropriately rated plenum cable where required by applicable building codes. Plenum-rated jackets address fire and smoke requirements in designated air-handling spaces.
CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests