Question 680
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A user deletes a critical folder and expects a mirrored RAID 1 drive to retain the files on the second disk. A user reports missing documents after a disk-repair utility runs, and the drive reports increasing read failures. Which course of action addresses the stated issues?
- Verify backup integrity and run a supported file-system integrity check when safe; confirm data ownership, recoverability and authorized disposal before erasing the drive.
- Restore from a separate backup or version history rather than from the live mirror; Minimize changes and follow approved forensic or backup-based recovery procedures.
- Verify backup integrity and run a supported file-system integrity check when safe; Minimize changes and follow approved forensic or backup-based recovery procedures.
- Restore from a separate backup or version history rather than from the live mirror; confirm data ownership, recoverability and authorized disposal before erasing the drive.
Explanation
Correct Answer
B:For ticket (1), Mirrors replicate deletions and cannot substitute for historical data protection. For ticket (2), Repeated repair writes can further damage fragile storage and reduce recovery chances.
Incorrect Answers
A:For ticket 1, restore from a separate backup or version history rather than from the live mirror. Mirrors replicate deletions and cannot substitute for historical data protection. For ticket 2, minimize changes and follow approved forensic or backup-based recovery procedures. Repeated repair writes can further damage fragile storage and reduce recovery chances.
C:For ticket 1, restore from a separate backup or version history rather than from the live mirror. Mirrors replicate deletions and cannot substitute for historical data protection.
D:For ticket 2, minimize changes and follow approved forensic or backup-based recovery procedures. Repeated repair writes can further damage fragile storage and reduce recovery chances.
Question 681
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A user deletes a critical folder and expects a mirrored RAID 1 drive to retain the files on the second disk. A desktop boot drive reports repeated file-system errors following forced shutdowns but passes the basic electrical health check. Which response best addresses these needs?
- Minimize changes and follow approved forensic or backup-based recovery procedures; verify backup integrity and run a supported file-system integrity check when safe.
- Restore from a separate backup or version history rather than from the live mirror; confirm data ownership, recoverability and authorized disposal before erasing the drive.
- Minimize changes and follow approved forensic or backup-based recovery procedures; confirm data ownership, recoverability and authorized disposal before erasing the drive.
- Restore from a separate backup or version history rather than from the live mirror; verify backup integrity and run a supported file-system integrity check when safe.
Explanation
Correct Answer
D:For ticket (1), Mirrors replicate deletions and cannot substitute for historical data protection. For ticket (2), File-system metadata corruption can occur without evidence of a physically failed drive.
Incorrect Answers
A:For ticket 1, restore from a separate backup or version history rather than from the live mirror. Mirrors replicate deletions and cannot substitute for historical data protection.
B:For ticket 2, verify backup integrity and run a supported file-system integrity check when safe. File-system metadata corruption can occur without evidence of a physically failed drive.
C:For ticket 1, restore from a separate backup or version history rather than from the live mirror. Mirrors replicate deletions and cannot substitute for historical data protection. For ticket 2, verify backup integrity and run a supported file-system integrity check when safe. File-system metadata corruption can occur without evidence of a physically failed drive.
Question 682
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A user reports missing documents after a disk-repair utility runs, and the drive reports increasing read failures. A technician wants to overwrite an old business SSD before checking whether the device contains the only copy of encrypted project data. What is the most appropriate plan for this situation?
- Minimize changes and follow approved forensic or backup-based recovery procedures; verify backup integrity and run a supported file-system integrity check when safe.
- Restore from a separate backup or version history rather than from the live mirror; verify backup integrity and run a supported file-system integrity check when safe.
- Minimize changes and follow approved forensic or backup-based recovery procedures; confirm data ownership, recoverability and authorized disposal before erasing the drive.
- Restore from a separate backup or version history rather than from the live mirror; confirm data ownership, recoverability and authorized disposal before erasing the drive.
Explanation
Correct Answer
C:For ticket (1), Repeated repair writes can further damage fragile storage and reduce recovery chances. For ticket (2), Destructive media operations must follow verified backup and data-retention requirements.
Incorrect Answers
A:For ticket 2, confirm data ownership, recoverability and authorized disposal before erasing the drive. Destructive media operations must follow verified backup and data-retention requirements.
B:For ticket 1, minimize changes and follow approved forensic or backup-based recovery procedures. Repeated repair writes can further damage fragile storage and reduce recovery chances. For ticket 2, confirm data ownership, recoverability and authorized disposal before erasing the drive. Destructive media operations must follow verified backup and data-retention requirements.
D:For ticket 1, minimize changes and follow approved forensic or backup-based recovery procedures. Repeated repair writes can further damage fragile storage and reduce recovery chances.
Question 683
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A desktop boot drive reports repeated file-system errors following forced shutdowns but passes the basic electrical health check. A technician wants to overwrite an old business SSD before checking whether the device contains the only copy of encrypted project data. Which course of action addresses the stated issues?
- Verify backup integrity and run a supported file-system integrity check when safe; confirm data ownership, recoverability and authorized disposal before erasing the drive.
- Restore from a separate backup or version history rather than from the live mirror; confirm data ownership, recoverability and authorized disposal before erasing the drive.
- Verify backup integrity and run a supported file-system integrity check when safe; Minimize changes and follow approved forensic or backup-based recovery procedures.
- Restore from a separate backup or version history rather than from the live mirror; Minimize changes and follow approved forensic or backup-based recovery procedures.
Explanation
Correct Answer
A:For ticket (1), File-system metadata corruption can occur without evidence of a physically failed drive. For ticket (2), Destructive media operations must follow verified backup and data-retention requirements.
Incorrect Answers
B:For ticket 1, verify backup integrity and run a supported file-system integrity check when safe. File-system metadata corruption can occur without evidence of a physically failed drive.
C:For ticket 2, confirm data ownership, recoverability and authorized disposal before erasing the drive. Destructive media operations must follow verified backup and data-retention requirements.
D:For ticket 1, verify backup integrity and run a supported file-system integrity check when safe. File-system metadata corruption can occur without evidence of a physically failed drive. For ticket 2, confirm data ownership, recoverability and authorized disposal before erasing the drive. Destructive media operations must follow verified backup and data-retention requirements.
Question 684
A service coordinator has THREE separate support tickets and needs the correct matching actions: A user deletes a critical folder and expects a mirrored RAID 1 drive to retain the files on the second disk. A user reports missing documents after a disk-repair utility runs, and the drive reports increasing read failures. A desktop boot drive reports repeated file-system errors following forced shutdowns but passes the basic electrical health check. Which response best addresses these needs?
- Restore from a separate backup or version history rather than from the live mirror; Minimize changes and follow approved forensic or backup-based recovery procedures; and confirm data ownership, recoverability and authorized disposal before erasing the drive.
- Restore from a separate backup or version history rather than from the live mirror; Minimize changes and follow approved forensic or backup-based recovery procedures; and verify backup integrity and run a supported file-system integrity check when safe.
- Confirm data ownership, recoverability and authorized disposal before erasing the drive; Minimize changes and follow approved forensic or backup-based recovery procedures; and verify backup integrity and run a supported file-system integrity check when safe.
- Restore from a separate backup or version history rather than from the live mirror; confirm data ownership, recoverability and authorized disposal before erasing the drive; and verify backup integrity and run a supported file-system integrity check when safe.
Explanation
Correct Answer
B:For ticket (1), Mirrors replicate deletions and cannot substitute for historical data protection. For ticket (2), Repeated repair writes can further damage fragile storage and reduce recovery chances. For ticket (3), File-system metadata corruption can occur without evidence of a physically failed drive.
Incorrect Answers
A:For ticket 3, verify backup integrity and run a supported file-system integrity check when safe. File-system metadata corruption can occur without evidence of a physically failed drive.
C:For ticket 1, restore from a separate backup or version history rather than from the live mirror. Mirrors replicate deletions and cannot substitute for historical data protection.
D:For ticket 2, minimize changes and follow approved forensic or backup-based recovery procedures. Repeated repair writes can further damage fragile storage and reduce recovery chances.
Question 685
During a controlled office IT maintenance window, the technician notes: A RAID 1 controller reports a degraded mirror after one physical disk failed, but the surviving member remains accessible. What is the MOST appropriate technician action?
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Restore data from an independent backup, because RAID 0 has no redundancy.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly.
Explanation
Correct Answer
C:Mirroring can maintain availability after one failed disk while redundancy must be restored.
Incorrect Answers
A:Prioritizing protected recovery and validated backups rather than assume the array can survive a third failure would not replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan.
B:Restoring data from an independent backup, because RAID 0 has no redundancy would not replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan.
D:Avoid additional member removal and follow the controller-supported recovery procedure promptly would not replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan.
Question 686
A support case documents the following situation: A RAID 5 array already has one failed drive and an operator plans to remove a second drive while users still need data. Which response BEST addresses the actual cause or requirement?
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Restore data from an independent backup, because RAID 0 has no redundancy.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly.
Explanation
Correct Answer
D:Traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
Incorrect Answers
A:Dual parity tolerates at most two failed members under normal RAID 6 assumptions; traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
B:Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency; traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
C:Mirroring can maintain availability after one failed disk while redundancy must be restored; traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
Question 687
A device support specialist must respond to this request: A RAID 6 set shows two failed members and a third disk develops errors during attempted rebuild. Which next step MOST directly resolves the reported condition?
- Avoid additional member removal and follow the controller-supported recovery procedure promptly.
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Restore data from an independent backup, because RAID 0 has no redundancy.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan.
Explanation
Correct Answer
B:Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
Incorrect Answers
A:Avoid additional member removal and follow the controller-supported recovery procedure promptly would not prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
C:Restoring data from an independent backup, because RAID 0 has no redundancy would not prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
D:Replacing the failed member with a supported disk and monitoring the mirror rebuild under the recovery plan would not prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
Question 688
An end user reports the following condition: A technician believes a RAID 0 striped volume can be rebuilt from one surviving disk after the other has failed. What should the support specialist recommend FIRST within the stated limits?
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly.
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Restore data from an independent backup, because RAID 0 has no redundancy.
Explanation
Correct Answer
D:Loss of a RAID 0 member commonly destroys the complete stripe set's data consistency.
Incorrect Answers
A:Replacing the failed member with a supported disk and monitoring the mirror rebuild under the recovery plan would not restore data from an independent backup, because RAID 0 has no redundancy.
B:Avoid additional member removal and follow the controller-supported recovery procedure promptly would not restore data from an independent backup, because RAID 0 has no redundancy.
C:Prioritizing protected recovery and validated backups rather than assume the array can survive a third failure would not restore data from an independent backup, because RAID 0 has no redundancy.
Question 689
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A RAID 1 controller reports a degraded mirror after one physical disk failed, but the surviving member remains accessible. A RAID 5 array already has one failed drive and an operator plans to remove a second drive while users still need data. Which course of action addresses the stated issues?
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; Avoid additional member removal and follow the controller-supported recovery procedure promptly.
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure; Avoid additional member removal and follow the controller-supported recovery procedure promptly.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; restore data from an independent backup, because RAID 0 has no redundancy.
- Prioritize protected recovery and validated backups rather than assume the array can survive a third failure; restore data from an independent backup, because RAID 0 has no redundancy.
Explanation
Correct Answer
A:For ticket (1), Mirroring can maintain availability after one failed disk while redundancy must be restored. For ticket (2), Traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
Incorrect Answers
B:For ticket 1, replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan. Mirroring can maintain availability after one failed disk while redundancy must be restored.
C:For ticket 2, avoid additional member removal and follow the controller-supported recovery procedure promptly. Traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
D:For ticket 1, replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan. Mirroring can maintain availability after one failed disk while redundancy must be restored. For ticket 2, avoid additional member removal and follow the controller-supported recovery procedure promptly. Traditional RAID 5 cannot tolerate two simultaneous member-drive failures.
Question 690
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A RAID 1 controller reports a degraded mirror after one physical disk failed, but the surviving member remains accessible. A RAID 6 set shows two failed members and a third disk develops errors during attempted rebuild. Which response best addresses these needs?
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; restore data from an independent backup, because RAID 0 has no redundancy.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly; restore data from an independent backup, because RAID 0 has no redundancy.
- Replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan; prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
- Avoid additional member removal and follow the controller-supported recovery procedure promptly; prioritize protected recovery and validated backups rather than assume the array can survive a third failure.
Explanation
Correct Answer
C:For ticket (1), Mirroring can maintain availability after one failed disk while redundancy must be restored. For ticket (2), Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
Incorrect Answers
A:For ticket 2, prioritize protected recovery and validated backups rather than assume the array can survive a third failure. Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
B:For ticket 1, replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan. Mirroring can maintain availability after one failed disk while redundancy must be restored. For ticket 2, prioritize protected recovery and validated backups rather than assume the array can survive a third failure. Dual parity tolerates at most two failed members under normal RAID 6 assumptions.
D:For ticket 1, replace the failed member with a supported disk and monitor the mirror rebuild under the recovery plan. Mirroring can maintain availability after one failed disk while redundancy must be restored.
CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests