Question 620
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A cable run is terminated using a different pair order at each end, and performance becomes unstable across longer distances. A remote building's fiber link flaps after dirt is observed on an LC connector ferrule. Which course of action addresses the stated issues?
- Re-terminate to a consistent T568A or T568B scheme and certify pair mapping; Repair or replace the cable and retest all required pairs.
- Replace the faulty patch lead and verify correct termination and continuity; Repair or replace the cable and retest all required pairs.
- Re-terminate to a consistent T568A or T568B scheme and certify pair mapping; Follow approved fiber cleaning and inspection procedures before replacing the network switch.
- Replace the faulty patch lead and verify correct termination and continuity; Follow approved fiber cleaning and inspection procedures before replacing the network switch.
Explanation
Correct Answer
C:For ticket (1), Pair miswiring can create split-pair and signal-quality problems even when continuity appears present. For ticket (2), Optical contamination can attenuate signals enough to cause intermittent connectivity.
Incorrect Answers
A:For ticket 2, follow approved fiber cleaning and inspection procedures before replacing the network switch. Optical contamination can attenuate signals enough to cause intermittent connectivity.
B:For ticket 1, re-terminate to a consistent T568A or T568B scheme and certify pair mapping. Pair miswiring can create split-pair and signal-quality problems even when continuity appears present. For ticket 2, follow approved fiber cleaning and inspection procedures before replacing the network switch. Optical contamination can attenuate signals enough to cause intermittent connectivity.
D:For ticket 1, re-terminate to a consistent T568A or T568B scheme and certify pair mapping. Pair miswiring can create split-pair and signal-quality problems even when continuity appears present.
Question 621
A service coordinator has THREE separate support tickets and needs the correct matching actions: A desktop Ethernet adapter reports no link light after cable routing changes, but the switch port tests healthy with another cable. An office uplink negotiates at 100 Mb/s instead of 1 Gb/s and a cable tester detects a missing twisted pair. A cable run is terminated using a different pair order at each end, and performance becomes unstable across longer distances. Which response best addresses these needs?
- Replace the faulty patch lead and verify correct termination and continuity; Follow approved fiber cleaning and inspection procedures before replacing the network switch; and Re-terminate to a consistent T568A or T568B scheme and certify pair mapping.
- Replace the faulty patch lead and verify correct termination and continuity; Repair or replace the cable and retest all required pairs; and Follow approved fiber cleaning and inspection procedures before replacing the network switch.
- Replace the faulty patch lead and verify correct termination and continuity; Repair or replace the cable and retest all required pairs; and Re-terminate to a consistent T568A or T568B scheme and certify pair mapping.
- Follow approved fiber cleaning and inspection procedures before replacing the network switch; Repair or replace the cable and retest all required pairs; and Re-terminate to a consistent T568A or T568B scheme and certify pair mapping.
Explanation
Correct Answer
C:For ticket (1), A broken copper pair can stop physical link negotiation even with functioning endpoints. For ticket (2), Gigabit twisted-pair Ethernet requires all four correctly connected pairs. For ticket (3), Pair miswiring can create split-pair and signal-quality problems even when continuity appears present.
Incorrect Answers
A:For ticket 2, repair or replace the cable and retest all required pairs. Gigabit twisted-pair Ethernet requires all four correctly connected pairs.
B:For ticket 3, re-terminate to a consistent T568A or T568B scheme and certify pair mapping. Pair miswiring can create split-pair and signal-quality problems even when continuity appears present.
D:For ticket 1, replace the faulty patch lead and verify correct termination and continuity. A broken copper pair can stop physical link negotiation even with functioning endpoints.
Question 622
A support case documents the following situation: A technician needs to attach an RJ45 plug to a prepared Ethernet cable for a field repair. Which response BEST addresses the actual cause or requirement?
- Use an appropriate punchdown tool for the insulation-displacement contacts.
- Use an approved toner and probe with a controlled tracing process.
- Check the cable pinout and continuity with a suitable cable tester.
- Use a compatible crimping tool and follow the selected wiring standard.
Explanation
Correct Answer
D:A crimper secures a modular connector and must match the cable and plug construction.
Incorrect Answers
A:Jack termination typically seats individual conductors into punchdown contacts rather than plugs; a crimper secures a modular connector and must match the cable and plug construction.
B:A tone generator and probe help locate and identify cable paths; a crimper secures a modular connector and must match the cable and plug construction.
C:Visual appearance cannot establish all conductor paths and correct pair mapping; a crimper secures a modular connector and must match the cable and plug construction.
Question 623
A device support specialist must respond to this request: An installer terminates horizontal twisted-pair cabling into a wall jack and tries to use an RJ45 plug crimper. Which next step MOST directly resolves the reported condition?
- Use an appropriate punchdown tool for the insulation-displacement contacts.
- Use an approved toner and probe with a controlled tracing process.
- Check the cable pinout and continuity with a suitable cable tester.
- Use a compatible crimping tool and follow the selected wiring standard.
Explanation
Correct Answer
A:Jack termination typically seats individual conductors into punchdown contacts rather than plugs.
Incorrect Answers
B:A tone generator and probe help locate and identify cable paths; jack termination typically seats individual conductors into punchdown contacts rather than plugs.
C:Visual appearance cannot establish all conductor paths and correct pair mapping; jack termination typically seats individual conductors into punchdown contacts rather than plugs.
D:A crimper secures a modular connector and must match the cable and plug construction; jack termination typically seats individual conductors into punchdown contacts rather than plugs.
Question 624
An end user reports the following condition: A long cable disappears into a shared cabinet, and the technician must identify the correct far-end run without unplugging every device. What should the support specialist recommend FIRST within the stated limits?
- Check the cable pinout and continuity with a suitable cable tester.
- Use a compatible crimping tool and follow the selected wiring standard.
- Use an appropriate punchdown tool for the insulation-displacement contacts.
- Use an approved toner and probe with a controlled tracing process.
Explanation
Correct Answer
D:A tone generator and probe help locate and identify cable paths.
Incorrect Answers
A:Visual appearance cannot establish all conductor paths and correct pair mapping; a tone generator and probe help locate and identify cable paths.
B:A crimper secures a modular connector and must match the cable and plug construction; a tone generator and probe help locate and identify cable paths.
C:Jack termination typically seats individual conductors into punchdown contacts rather than plugs; a tone generator and probe help locate and identify cable paths.
Question 625
A help desk receives a support ticket with this evidence: A new Ethernet cable passes a visual inspection but one conductor is open and the computer negotiates no link. What is the MOST appropriate technician action?
- Use a compatible crimping tool and follow the selected wiring standard.
- Use an appropriate punchdown tool for the insulation-displacement contacts.
- Use an approved toner and probe with a controlled tracing process.
- Check the cable pinout and continuity with a suitable cable tester.
Explanation
Correct Answer
D:Visual appearance cannot establish all conductor paths and correct pair mapping.
Incorrect Answers
A:A crimper secures a modular connector and must match the cable and plug construction; visual appearance cannot establish all conductor paths and correct pair mapping.
B:Jack termination typically seats individual conductors into punchdown contacts rather than plugs; visual appearance cannot establish all conductor paths and correct pair mapping.
C:A tone generator and probe help locate and identify cable paths; visual appearance cannot establish all conductor paths and correct pair mapping.
Question 626
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A technician needs to attach an RJ45 plug to a prepared Ethernet cable for a field repair. An installer terminates horizontal twisted-pair cabling into a wall jack and tries to use an RJ45 plug crimper. Which course of action addresses the stated issues?
- Use a compatible crimping tool and follow the selected wiring standard; use an appropriate punchdown tool for the insulation-displacement contacts.
- Use an approved toner and probe with a controlled tracing process; use an appropriate punchdown tool for the insulation-displacement contacts.
- Use a compatible crimping tool and follow the selected wiring standard; check the cable pinout and continuity with a suitable cable tester.
- Use an approved toner and probe with a controlled tracing process; check the cable pinout and continuity with a suitable cable tester.
Explanation
Correct Answer
A:For ticket (1), A crimper secures a modular connector and must match the cable and plug construction. For ticket (2), Jack termination typically seats individual conductors into punchdown contacts rather than plugs.
Incorrect Answers
B:For ticket 1, use a compatible crimping tool and follow the selected wiring standard. A crimper secures a modular connector and must match the cable and plug construction.
C:For ticket 2, use an appropriate punchdown tool for the insulation-displacement contacts. Jack termination typically seats individual conductors into punchdown contacts rather than plugs.
D:For ticket 1, use a compatible crimping tool and follow the selected wiring standard. A crimper secures a modular connector and must match the cable and plug construction. For ticket 2, use an appropriate punchdown tool for the insulation-displacement contacts. Jack termination typically seats individual conductors into punchdown contacts rather than plugs.
Question 627
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A technician needs to attach an RJ45 plug to a prepared Ethernet cable for a field repair. A long cable disappears into a shared cabinet, and the technician must identify the correct far-end run without unplugging every device. Which response best addresses these needs?
- Use an appropriate punchdown tool for the insulation-displacement contacts; use an approved toner and probe with a controlled tracing process.
- Use a compatible crimping tool and follow the selected wiring standard; check the cable pinout and continuity with a suitable cable tester.
- Use an appropriate punchdown tool for the insulation-displacement contacts; check the cable pinout and continuity with a suitable cable tester.
- Use a compatible crimping tool and follow the selected wiring standard; use an approved toner and probe with a controlled tracing process.
Explanation
Correct Answer
D:For ticket (1), A crimper secures a modular connector and must match the cable and plug construction. For ticket (2), A tone generator and probe help locate and identify cable paths.
Incorrect Answers
A:For ticket 1, use a compatible crimping tool and follow the selected wiring standard. A crimper secures a modular connector and must match the cable and plug construction.
B:For ticket 2, use an approved toner and probe with a controlled tracing process. A tone generator and probe help locate and identify cable paths.
C:For ticket 1, use a compatible crimping tool and follow the selected wiring standard. A crimper secures a modular connector and must match the cable and plug construction. For ticket 2, use an approved toner and probe with a controlled tracing process. A tone generator and probe help locate and identify cable paths.
Question 628
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: An installer terminates horizontal twisted-pair cabling into a wall jack and tries to use an RJ45 plug crimper. A new Ethernet cable passes a visual inspection but one conductor is open and the computer negotiates no link. What is the most appropriate plan for this situation?
- Use a compatible crimping tool and follow the selected wiring standard; use an approved toner and probe with a controlled tracing process.
- Use an appropriate punchdown tool for the insulation-displacement contacts; check the cable pinout and continuity with a suitable cable tester.
- Use a compatible crimping tool and follow the selected wiring standard; check the cable pinout and continuity with a suitable cable tester.
- Use an appropriate punchdown tool for the insulation-displacement contacts; use an approved toner and probe with a controlled tracing process.
Explanation
Correct Answer
B:For ticket (1), Jack termination typically seats individual conductors into punchdown contacts rather than plugs. For ticket (2), Visual appearance cannot establish all conductor paths and correct pair mapping.
Incorrect Answers
A:For ticket 1, use an appropriate punchdown tool for the insulation-displacement contacts. Jack termination typically seats individual conductors into punchdown contacts rather than plugs. For ticket 2, check the cable pinout and continuity with a suitable cable tester. Visual appearance cannot establish all conductor paths and correct pair mapping.
C:For ticket 1, use an appropriate punchdown tool for the insulation-displacement contacts. Jack termination typically seats individual conductors into punchdown contacts rather than plugs.
D:For ticket 2, check the cable pinout and continuity with a suitable cable tester. Visual appearance cannot establish all conductor paths and correct pair mapping.
Question 629
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A long cable disappears into a shared cabinet, and the technician must identify the correct far-end run without unplugging every device. A new Ethernet cable passes a visual inspection but one conductor is open and the computer negotiates no link. Which course of action addresses the stated issues?
- Use an approved toner and probe with a controlled tracing process; use an appropriate punchdown tool for the insulation-displacement contacts.
- Use a compatible crimping tool and follow the selected wiring standard; use an appropriate punchdown tool for the insulation-displacement contacts.
- Use an approved toner and probe with a controlled tracing process; check the cable pinout and continuity with a suitable cable tester.
- Use a compatible crimping tool and follow the selected wiring standard; check the cable pinout and continuity with a suitable cable tester.
Explanation
Correct Answer
C:For ticket (1), A tone generator and probe help locate and identify cable paths. For ticket (2), Visual appearance cannot establish all conductor paths and correct pair mapping.
Incorrect Answers
A:For ticket 2, check the cable pinout and continuity with a suitable cable tester. Visual appearance cannot establish all conductor paths and correct pair mapping.
B:For ticket 1, use an approved toner and probe with a controlled tracing process. A tone generator and probe help locate and identify cable paths. For ticket 2, check the cable pinout and continuity with a suitable cable tester. Visual appearance cannot establish all conductor paths and correct pair mapping.
D:For ticket 1, use an approved toner and probe with a controlled tracing process. A tone generator and probe help locate and identify cable paths.
Question 630
A service coordinator has THREE separate support tickets and needs the correct matching actions: A technician needs to attach an RJ45 plug to a prepared Ethernet cable for a field repair. An installer terminates horizontal twisted-pair cabling into a wall jack and tries to use an RJ45 plug crimper. A long cable disappears into a shared cabinet, and the technician must identify the correct far-end run without unplugging every device. Which response best addresses these needs?
- Check the cable pinout and continuity with a suitable cable tester; use an appropriate punchdown tool for the insulation-displacement contacts; and use an approved toner and probe with a controlled tracing process.
- Use a compatible crimping tool and follow the selected wiring standard; check the cable pinout and continuity with a suitable cable tester; and use an approved toner and probe with a controlled tracing process.
- Use a compatible crimping tool and follow the selected wiring standard; use an appropriate punchdown tool for the insulation-displacement contacts; and check the cable pinout and continuity with a suitable cable tester.
- Use a compatible crimping tool and follow the selected wiring standard; use an appropriate punchdown tool for the insulation-displacement contacts; and use an approved toner and probe with a controlled tracing process.
Explanation
Correct Answer
D:For ticket (1), A crimper secures a modular connector and must match the cable and plug construction. For ticket (2), Jack termination typically seats individual conductors into punchdown contacts rather than plugs. For ticket (3), A tone generator and probe help locate and identify cable paths.
Incorrect Answers
A:For ticket 1, use a compatible crimping tool and follow the selected wiring standard. A crimper secures a modular connector and must match the cable and plug construction.
B:For ticket 2, use an appropriate punchdown tool for the insulation-displacement contacts. Jack termination typically seats individual conductors into punchdown contacts rather than plugs.
C:For ticket 3, use an approved toner and probe with a controlled tracing process. A tone generator and probe help locate and identify cable paths.
CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests