Pass Your Cisco 350-601 Exam Easy!

Cisco 350-601 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

350-601 Premium Bundle

$74.99

Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
Cisco 350-601 Premium Bundle
Cisco 350-601 Premium Bundle

350-601 Premium File: 630 Questions & Answers

Last Update: Nov 17, 2026

350-601 Training Course: 143 Video Lectures

$74.99

350-601 Bundle gives you unlimited access to "350-601" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

Cisco 350-601 Practice Test 81

Question 800

A C-Series host repeatedly boots local media even though its approved UCS policy specifies a SAN boot target. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What is the strongest technical basis for the recommended action?

  1. Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure.
  2. Packet replication can reveal TCP and frame-level behavior that interface counters summarize only coarsely.
  3. The effective boot order and accessible target devices determine which source a Cisco server attempts during initialization.
  4. Physical power or cooling constraints can throttle compute even when guest metrics show no software error.

Explanation

Correct Answer

C:

The effective boot order and accessible target devices determine which source a Cisco server attempts during initialization. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.

Incorrect Answers

A:

Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure. This concerns UCS restore integrity, not c-series boot policy alignment.

B:

Packet replication can reveal TCP and frame-level behavior that interface counters summarize only coarsely. This concerns compute traffic span, not c-series boot policy alignment.

D:

Physical power or cooling constraints can throttle compute even when guest metrics show no software error. This concerns chassis power and thermal monitoring, not c-series boot policy alignment.

Question 801

A SAN array replaces a target HBA but operators try to keep its old WWPN hidden behind the same device alias without verification. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What should the operator avoid assuming from the observed state?

  1. Assuming that every local command is distributed automatically can leave peers inconsistent.
  2. An old name-server entry for the former target port does not prove the replacement path is live.
  3. A friendly alias name is not a substitute for a correct underlying port WWPN.
  4. Turning on NPV alone does not create initiator logins if upstream NPIV is unavailable.

Explanation

Correct Answer

C:

A friendly alias name is not a substitute for a correct underlying port WWPN. Device aliases map readable names to FC identifiers and must follow actual hardware identity changes. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.

Incorrect Answers

A:

Assuming that every local command is distributed automatically can leave peers inconsistent. This concerns cisco fabric services distribution, not device alias maintenance.

B:

An old name-server entry for the former target port does not prove the replacement path is live. This concerns fibre channel name-server entries, not device alias maintenance.

D:

Turning on NPV alone does not create initiator logins if upstream NPIV is unavailable. This concerns npv uplink fabric services, not device alias maintenance.

Question 802

An operations team sees sporadic storage-path instability but its monitoring only polls device availability every five minutes. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which evidence set most directly tests the suspected failure?

  1. Inspect SAN fabric health, interface utilization, link events, VSAN membership and path timelines.
  2. Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples.
  3. Inspect current/target images, supported upgrade matrix, module health and connected-host multipathing.
  4. Inspect MDS platform release notes, EPLD package compatibility, reload dependencies and alternate paths.

Explanation

Correct Answer

A:

Inspect SAN fabric health, interface utilization, link events, VSAN membership and path timelines. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Topology, fabric events and time-series indicators reveal path problems hidden by simple reachability polling. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

B:

Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples. This concerns SAN port error telemetry, not nexus dashboard SAN monitoring.

C:

Inspect current/target images, supported upgrade matrix, module health and connected-host multipathing. This concerns mds nondisruptive upgrade planning, not nexus dashboard SAN monitoring.

D:

Inspect MDS platform release notes, EPLD package compatibility, reload dependencies and alternate paths. This concerns mds epld update impact, not nexus dashboard SAN monitoring.

Question 803

A VXLAN tenant sees ARP requests at one VTEP but not at another after a change to head-end replication peers. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which intervention most directly addresses the stated condition?

  1. Classify the architecture using the NIST deployment definitions and document the interaction between distinct cloud infrastructures.
  2. Advertise and verify the VTEP source-loopback reachability in the underlay routing domain.
  3. Correct the L3 VNI and tenant VRF association and check EVPN route import/export on participating VTEPs.
  4. Validate the VNI's BUM replication configuration and peer membership before changing unicast forwarding.

Explanation

Correct Answer

D:

Validate the VNI's BUM replication configuration and peer membership before changing unicast forwarding. Unknown-unicast, broadcast and multicast frames require an appropriate VXLAN replication or multicast transport method. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

Classify the architecture using the NIST deployment definitions and document the interaction between distinct cloud infrastructures. This concerns hybrid cloud model classification, not bum replication behavior.

B:

Advertise and verify the VTEP source-loopback reachability in the underlay routing domain. This concerns vxlan vtep underlay reachability, not bum replication behavior.

C:

Correct the L3 VNI and tenant VRF association and check EVPN route import/export on participating VTEPs. This concerns evpn vni-to-vrf mapping, not bum replication behavior.

Question 804

Storage latency rises whenever a particular MDS uplink is busy, and CRC errors increase on that same port. A storage change board requires a traceable diagnosis before allowing further fabric changes. Which observations would best validate the initial diagnosis?

  1. Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs.
  2. Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples.
  3. Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries.
  4. Inspect trunk allowed lists, operational VSANs, fcdomain state and VSAN-specific fabric links.

Explanation

Correct Answer

B:

Inspect FC interface counters, optics diagnostics, cable health and correlated latency samples. These records help distinguish the suspected failure from a superficially similar fault before modifying production. CRC and link-level errors can indicate transport impairment rather than a storage-array performance limitation. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. This concerns VSAN isolation, not SAN port error telemetry.

C:

Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. This concerns wwpn versus wwnn, not SAN port error telemetry.

D:

Inspect trunk allowed lists, operational VSANs, fcdomain state and VSAN-specific fabric links. This concerns VSAN trunk mismatch, not SAN port error telemetry.

Question 805

A storage administrator zones a host using a node name although the fabric login is registered with a different port identifier. A storage change board requires a traceable diagnosis before allowing further fabric changes. What information should be inspected before the change is applied?

  1. Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs.
  2. Inspect current/target images, supported upgrade matrix, module health and connected-host multipathing.
  3. Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries.
  4. Inspect trunk allowed lists, operational VSANs, fcdomain state and VSAN-specific fabric links.

Explanation

Correct Answer

C:

Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Fibre Channel port WWNs identify individual interfaces used by fabric login and zoning policies. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. That response is associated with vsan isolation rather than the specific wwpn versus wwnn condition described here. For the stated failure, the preferred action is: Use the correct initiator and target port WWPNs when creating the required zone memberships. Relevant evidence: Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. A storage change board requires a traceable diagnosis before allowing further fabric changes.

B:

Inspect current/target images, supported upgrade matrix, module health and connected-host multipathing. This concerns mds nondisruptive upgrade planning, not wwpn versus wwnn.

D:

Inspect trunk allowed lists, operational VSANs, fcdomain state and VSAN-specific fabric links. That response is associated with vsan trunk mismatch rather than the specific wwpn versus wwnn condition described here. For the stated failure, the preferred action is: Use the correct initiator and target port WWPNs when creating the required zone memberships. Relevant evidence: Inspect FLOGI port WWPNs, host vHBA identities, target port IDs and zoning entries. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Question 806

An operator plans an EPLD firmware update during a business peak because a software patch earlier completed without traffic loss. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What is the strongest technical basis for the recommended action?

  1. An FHRP keeps a virtual default gateway available while members transition between active and standby roles.
  2. MP-BGP session establishment does not guarantee tenant routes will be imported when policy attributes mismatch.
  3. Programmable-logic updates can require component reset or reload even when an unrelated software patch did not.
  4. Model-driven telemetry can provide pushed state updates more frequently than coarse periodic polling.

Explanation

Correct Answer

C:

Programmable-logic updates can require component reset or reload even when an unrelated software patch did not. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

A:

An FHRP keeps a virtual default gateway available while members transition between active and standby roles. This concerns first-hop gateway failover, not epld firmware maintenance.

B:

MP-BGP session establishment does not guarantee tenant routes will be imported when policy attributes mismatch. This concerns mp-BGP tenant route import, not epld firmware maintenance.

D:

Model-driven telemetry can provide pushed state updates more frequently than coarse periodic polling. This concerns streaming telemetry health, not epld firmware maintenance.

Question 807

A Nexus access VLAN with Dynamic ARP Inspection enabled begins dropping legitimate hosts that use static addressing. A follow-up access review asks the team to validate the same boundary with a controlled negative test. How should the implementation be validated against the original failure?

  1. Tagged VMs appear in the intended microsegmented EPG and only approved flows traverse the boundary.
  2. Only the approved application ports work between the two EPGs while nonapproved flows remain blocked.
  3. Authorized static hosts pass ARP inspection while forged bindings remain blocked.
  4. Clients obtain leases from the authorized server and rogue DHCP replies on access ports are still rejected.

Explanation

Correct Answer

C:

Authorized static hosts pass ARP inspection while forged bindings remain blocked. This result tests the original failure rather than reporting merely that the configuration command was accepted. DAI verifies ARP bindings using trusted information and may reject legitimate fixed-address hosts without an authorized binding. A follow-up access review asks the team to validate the same boundary with a controlled negative test.

Incorrect Answers

A:

Tagged VMs appear in the intended microsegmented EPG and only approved flows traverse the boundary. This concerns aci microsegmentation selector, not dynamic ARP inspection source of truth.

B:

Only the approved application ports work between the two EPGs while nonapproved flows remain blocked. This concerns aci inter-epg contract, not dynamic ARP inspection source of truth.

D:

Clients obtain leases from the authorized server and rogue DHCP replies on access ports are still rejected. This concerns DHCP snooping trusted uplink, not dynamic ARP inspection source of truth.

Question 808

An ISL trunk is up but one VSAN loses connectivity because it is missing from the allowed or operational VSAN set. A storage change board requires a traceable diagnosis before allowing further fabric changes. What should the operator avoid assuming from the observed state?

  1. Redundant supervisors do not make every FC software version transition nondisruptive.
  2. A link-up indicator for the parent trunk does not prove that every intended VSAN is carried.
  3. An ordinary Fibre Channel zone does not by itself create a separate control-plane fabric.
  4. A node-level WWNN cannot always replace a port-specific WWPN expected by the zoning policy.

Explanation

Correct Answer

B:

A link-up indicator for the parent trunk does not prove that every intended VSAN is carried. A physical Fibre Channel ISL can stay up while excluding a particular VSAN from carried fabric traffic. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Incorrect Answers

A:

Redundant supervisors do not make every FC software version transition nondisruptive. This concerns mds nondisruptive upgrade planning, not VSAN trunk mismatch.

C:

An ordinary Fibre Channel zone does not by itself create a separate control-plane fabric. That response is associated with vsan isolation rather than the specific vsan trunk mismatch condition described here. For the stated failure, the preferred action is: Align trunk allowed VSANs and verify the operational VSAN membership end to end. Relevant evidence: Inspect trunk allowed lists, operational VSANs, fcdomain state and VSAN-specific fabric links. A storage change board requires a traceable diagnosis before allowing further fabric changes.

D:

A node-level WWNN cannot always replace a port-specific WWPN expected by the zoning policy. That response is associated with wwpn versus wwnn rather than the specific vsan trunk mismatch condition described here. For the stated failure, the preferred action is: Align trunk allowed VSANs and verify the operational VSAN membership end to end. Relevant evidence: Inspect trunk allowed lists, operational VSANs, fcdomain state and VSAN-specific fabric links. A storage change board requires a traceable diagnosis before allowing further fabric changes.

Question 809

Two Nexus leaf switches never form an OSPF adjacency after one interface was moved into the backbone while the neighbor still uses a nonbackbone area. The team is preparing a controlled production change and must preserve fabric reachability. Which technical principle best explains the recommended response?

  1. EVPN distributes MAC and IP reachability using MP-BGP; underlay IP reachability alone cannot populate those bindings.
  2. OSPFv3 neighbors communicate over IPv6 link-local addresses and require compatible protocol and area settings.
  3. OSPF neighbors must agree on the area and relevant adjacency parameters to reach Full state and exchange routes correctly.
  4. VXLAN encapsulation depends on routable IP transport between VTEP endpoints before tenant traffic can traverse it.

Explanation

Correct Answer

C:

OSPF neighbors must agree on the area and relevant adjacency parameters to reach Full state and exchange routes correctly. The team is preparing a controlled production change and must preserve fabric reachability.

Incorrect Answers

A:

EVPN distributes MAC and IP reachability using MP-BGP; underlay IP reachability alone cannot populate those bindings. That response is associated with mp-bgp evpn route learning rather than the specific ospf area compatibility condition described here. For the stated failure, the preferred action is: Align the OSPF interface area and adjacency parameters on both neighbors before changing routing policy. Relevant evidence: Inspect neighbor state, interface area assignments, hello parameters and interface MTU on both peers. The team is preparing a controlled production change and must preserve fabric reachability.

B:

OSPFv3 neighbors communicate over IPv6 link-local addresses and require compatible protocol and area settings. That response is associated with ospfv3 ipv6 neighbor discovery rather than the specific ospf area compatibility condition described here. For the stated failure, the preferred action is: Align the OSPF interface area and adjacency parameters on both neighbors before changing routing policy. Relevant evidence: Inspect neighbor state, interface area assignments, hello parameters and interface MTU on both peers. The team is preparing a controlled production change and must preserve fabric reachability.

D:

VXLAN encapsulation depends on routable IP transport between VTEP endpoints before tenant traffic can traverse it. This concerns vxlan vtep underlay reachability, not OSPF area compatibility.

Question 810

Receivers on a routed multicast fabric join a group, but sources in another subnet do not reach them after an RP address change. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What is the strongest technical basis for the recommended action?

  1. PIM sparse mode relies on correct multicast routing state and, where applicable, an RP for shared-tree discovery.
  2. An FHRP keeps a virtual default gateway available while members transition between active and standby roles.
  3. OSPFv3 neighbors communicate over IPv6 link-local addresses and require compatible protocol and area settings.
  4. EVPN distributes MAC and IP reachability using MP-BGP; underlay IP reachability alone cannot populate those bindings.

Explanation

Correct Answer

A:

PIM sparse mode relies on correct multicast routing state and, where applicable, an RP for shared-tree discovery. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.

Incorrect Answers

B:

An FHRP keeps a virtual default gateway available while members transition between active and standby roles. This concerns first-hop gateway failover, not PIM multicast rendezvous point.

C:

OSPFv3 neighbors communicate over IPv6 link-local addresses and require compatible protocol and area settings. This concerns ospfv3 IPv6 neighbor discovery, not PIM multicast rendezvous point.

D:

EVPN distributes MAC and IP reachability using MP-BGP; underlay IP reachability alone cannot populate those bindings. This concerns mp-BGP evpn route learning, not PIM multicast rendezvous point.


Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests

Purchase Individually

350-601 Premium File

Premium File
350-601 Premium File
630 Q&A
$76.99$69.99

350-601 Training Video Course

Training Course
350-601 Training Video Course
143 Lectures
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.