Question 770
A new Fibre Channel host is connected to an MDS switch but never receives a fabric identifier and cannot discover targets. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What should the engineer collect before ruling out other causes?
- Inspect fcdomain status, assigned domain IDs, ISL events and active FCID allocations.
- Inspect SAN port-channel summary, member compatibility results, link speeds and VSAN assignments.
- Inspect FCNS database, FLOGI records, target WWPN, VSAN association and port transition logs.
- Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events.
Explanation
Correct Answer
D:Inspect FC interface state, FLOGI database, initiator WWPN and relevant switch events. These records help distinguish the suspected failure from a superficially similar fault before modifying production. An initiator must complete fabric login and receive an FCID before normal fabric services can identify it. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.
Incorrect Answers
A:Inspect fcdomain status, assigned domain IDs, ISL events and active FCID allocations. This concerns fcid and domain id stability, not fibre channel fabric login.
B:Inspect SAN port-channel summary, member compatibility results, link speeds and VSAN assignments. This concerns fibre channel port-channel consistency, not fibre channel fabric login.
C:Inspect FCNS database, FLOGI records, target WWPN, VSAN association and port transition logs. This concerns fibre channel name-server entries, not fibre channel fabric login.
Question 771
A GPU training cluster reports reduced throughput when synchronized east-west traffic converges on a few uplinks despite healthy compute nodes. The automation change must pass a preproduction test and leave a verifiable audit trail. Which explanation most directly accounts for the required correction?
- Automation must distinguish unavailable telemetry from a real numeric zero to avoid false success reports.
- Retrying non-idempotent create operations without state checks can duplicate resources after ambiguous timeouts.
- An HTTP 403 indicates a reachable endpoint has refused the request under its authorization controls.
- Distributed AI jobs can be bottlenecked by data-center fabric transport when many nodes exchange bursts of data.
Explanation
Correct Answer
D:Distributed AI jobs can be bottlenecked by data-center fabric transport when many nodes exchange bursts of data. The automation change must pass a preproduction test and leave a verifiable audit trail.
Incorrect Answers
A:Automation must distinguish unavailable telemetry from a real numeric zero to avoid false success reports. This concerns on-box python exception handling, not ai cluster network congestion.
B:Retrying non-idempotent create operations without state checks can duplicate resources after ambiguous timeouts. This concerns rest api retries and idempotence, not ai cluster network congestion.
C:An HTTP 403 indicates a reachable endpoint has refused the request under its authorization controls. This concerns nx-api request authorization, not ai cluster network congestion.
Question 772
A storage administrator must inspect FC zoning health but an inherited MDS role grants access to fabric-wide reconfiguration. A follow-up access review asks the team to validate the same boundary with a controlled negative test. Which qualification should the change record include?
- Read-only CLI rights must not be assumed to limit every separate management API unless its roles are also scoped.
- A user with no host storage access might still alter SAN switch policy if management RBAC is too broad.
- Host-level WWPN zoning is not a substitute for constraining switch-to-switch fabric membership.
- Permissive fabric zoning does not itself guarantee that an unauthorized physical initiator cannot log in.
Explanation
Correct Answer
B:A user with no host storage access might still alter SAN switch policy if management RBAC is too broad. Storage network RBAC limits configuration actions independently of physical access to SAN switches. A follow-up access review asks the team to validate the same boundary with a controlled negative test.
Incorrect Answers
A:Read-only CLI rights must not be assumed to limit every separate management API unless its roles are also scoped. This concerns nx-os administrative RBAC, not mds SAN administrative control.
C:Host-level WWPN zoning is not a substitute for constraining switch-to-switch fabric membership. This concerns fabric binding membership, not mds SAN administrative control.
D:Permissive fabric zoning does not itself guarantee that an unauthorized physical initiator cannot log in. This concerns fibre channel port security, not mds SAN administrative control.
Question 773
After staging a server firmware upgrade, the adapter and BIOS target versions differ from the supported hardware compatibility matrix. Operations is validating the host before approving production workload placement. Which result would best confirm that the remediation worked?
- The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface.
- Applied firmware aligns with approved compatibility targets and the host remains healthy after validation.
- Traffic remains available across a controlled single-fabric interruption with expected failover behavior.
- All expected blades appear in managed inventory without persistent IOM fault alarms.
Explanation
Correct Answer
B:Applied firmware aligns with approved compatibility targets and the host remains healthy after validation. This result tests the original failure rather than reporting merely that the configuration command was accepted. A server and adapter firmware combination must be supported for its hardware and operating environment. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:The expected VLAN is present on the associated vNIC and tenant frames reach the correct upstream interface. This concerns UCS VLAN pool and template, not UCS firmware compatibility.
C:Traffic remains available across a controlled single-fabric interruption with expected failover behavior. This concerns UCS fabric redundancy, not UCS firmware compatibility.
D:All expected blades appear in managed inventory without persistent IOM fault alarms. This concerns UCS blade chassis IOM discovery, not UCS firmware compatibility.
Question 774
Two application teams use the same physical SAN switches but must keep their fabric control traffic separated. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. Which test result best demonstrates restoration of the intended behavior?
- The active zoneset contains the actual registered port WWPNs and the host discovers its target.
- The correct active zone now includes the initiator and target, and storage discovery succeeds.
- Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets.
- Each team's initiators and targets register only within the approved VSAN and access boundaries.
Explanation
Correct Answer
D:Each team's initiators and targets register only within the approved VSAN and access boundaries. This result tests the original failure rather than reporting merely that the configuration command was accepted. VSANs provide logical fabric separation across shared physical Fibre Channel infrastructure. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.
Incorrect Answers
A:The active zoneset contains the actual registered port WWPNs and the host discovers its target. This concerns wwpn versus wwnn, not VSAN isolation.
B:The correct active zone now includes the initiator and target, and storage discovery succeeds. This concerns zoneset activation state, not VSAN isolation.
C:Each authorized server vHBA appears logged in on the upstream fabric and discovers expected targets. This concerns npv uplink fabric services, not VSAN isolation.
Question 775
A virtualized host can ping the iSCSI target interface but discovers no storage sessions after a switch change. A storage change board requires a traceable diagnosis before allowing further fabric changes. What information should be inspected before the change is applied?
- Inspect target portal IPs, IQN access rules, CHAP policy, TCP reachability and multipath sessions.
- Inspect active zone members, initiator WWPNs, target WWPNs and intended host-to-LUN access matrices.
- Inspect CFS peers, lock ownership, pending changes, feature status and activation records.
- Inspect fcdomain status, assigned domain IDs, ISL events and active FCID allocations.
Explanation
Correct Answer
A:Inspect target portal IPs, IQN access rules, CHAP policy, TCP reachability and multipath sessions. These records help distinguish the suspected failure from a superficially similar fault before modifying production. iSCSI uses IP transport and initiator-target session controls rather than Fibre Channel fabric login. A storage change board requires a traceable diagnosis before allowing further fabric changes.
Incorrect Answers
B:Inspect active zone members, initiator WWPNs, target WWPNs and intended host-to-LUN access matrices. This concerns single-initiator zoning, not iscsi target discovery.
C:Inspect CFS peers, lock ownership, pending changes, feature status and activation records. This concerns cisco fabric services distribution, not iscsi target discovery.
D:Inspect fcdomain status, assigned domain IDs, ISL events and active FCID allocations. This concerns fcid and domain id stability, not iscsi target discovery.
Question 776
A Nexus switch upgrade has been described as nondisruptive, but the running hardware and target image are not confirmed as ISSU compatible. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. What post-change observation gives the strongest evidence of success?
- A supported upgrade plan is documented with rollback criteria and actual traffic behavior is validated afterward.
- Remote VTEP addresses resolve through the underlay and encapsulated tenant frames reach the remote leaf.
- Inter-subnet routes are installed in the correct VRF and authorized host traffic routes between VNIs.
- Virtual endpoints are learned in the intended EPG and their traffic follows its applied contracts.
Explanation
Correct Answer
A:A supported upgrade plan is documented with rollback criteria and actual traffic behavior is validated afterward. This result tests the original failure rather than reporting merely that the configuration command was accepted. Nondisruptive software upgrade support is platform, topology and image-path dependent and must be verified. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.
Incorrect Answers
B:Remote VTEP addresses resolve through the underlay and encapsulated tenant frames reach the remote leaf. This concerns vxlan vtep underlay reachability, not nexus issu eligibility.
C:Inter-subnet routes are installed in the correct VRF and authorized host traffic routes between VNIs. This concerns evpn vni-to-vrf mapping, not nexus issu eligibility.
D:Virtual endpoints are learned in the intended EPG and their traffic follows its applied contracts. This concerns aci vmm association, not nexus issu eligibility.
Question 777
A contractor must view Nexus interface health but currently has a role that can change routing and security configuration. Security engineering must restore the approved service without relaxing unrelated protection. What post-change observation gives the strongest evidence of success?
- Only approved device identities log in and the unauthorized initiator is denied without disrupting valid paths.
- Authorized recovery login works during a controlled AAA outage and normal centralized authentication resumes afterward.
- Only the approved application ports work between the two EPGs while nonapproved flows remain blocked.
- The contractor can view interface health but an attempted configuration change is denied and logged.
Explanation
Correct Answer
D:The contractor can view interface health but an attempted configuration change is denied and logged. This result tests the original failure rather than reporting merely that the configuration command was accepted. Role-based access control limits administrators to the commands and resources needed for their work. Security engineering must restore the approved service without relaxing unrelated protection.
Incorrect Answers
A:Only approved device identities log in and the unauthorized initiator is denied without disrupting valid paths. This concerns fibre channel port security, not nx-os administrative RBAC.
B:Authorized recovery login works during a controlled AAA outage and normal centralized authentication resumes afterward. That response is associated with centralized aaa fallback rather than the specific nx-os administrative rbac condition described here. For the stated failure, the preferred action is: Assign a restricted read-only RBAC role covering the required monitoring commands. Relevant evidence: Inspect assigned user roles, AAA server attributes, command authorization and audit logs. Security engineering must restore the approved service without relaxing unrelated protection.
C:Only the approved application ports work between the two EPGs while nonapproved flows remain blocked. That response is associated with aci inter-epg contract rather than the specific nx-os administrative rbac condition described here. For the stated failure, the preferred action is: Assign a restricted read-only RBAC role covering the required monitoring commands. Relevant evidence: Inspect assigned user roles, AAA server attributes, command authorization and audit logs. Security engineering must restore the approved service without relaxing unrelated protection.
Question 778
An on-box NX-OS Python maintenance script interprets a missing interface counter as zero and incorrectly reports healthy operation. The automation change must pass a preproduction test and leave a verifiable audit trail. Which intervention most directly addresses the stated condition?
- Verify the API user role, requested method and endpoint authorization before changing transport routing.
- Check API operation semantics and implement safe read-before-create or idempotent reconciliation behavior.
- Verify the Guest Shell environment, mounted paths and supported data-transfer method rather than assuming shared filesystems.
- Validate API responses and explicitly handle missing data before calculating health status.
Explanation
Correct Answer
D:Validate API responses and explicitly handle missing data before calculating health status. Automation must distinguish unavailable telemetry from a real numeric zero to avoid false success reports. The automation change must pass a preproduction test and leave a verifiable audit trail.
Incorrect Answers
A:Verify the API user role, requested method and endpoint authorization before changing transport routing. That response is associated with nx-api request authorization rather than the specific on-box python exception handling condition described here. For the stated failure, the preferred action is: Validate API responses and explicitly handle missing data before calculating health status. Relevant evidence: Inspect command return status, payload schema, missing fields, tracebacks and data freshness. The automation change must pass a preproduction test and leave a verifiable audit trail.
B:Check API operation semantics and implement safe read-before-create or idempotent reconciliation behavior. That response is associated with rest api retries and idempotence rather than the specific on-box python exception handling condition described here. For the stated failure, the preferred action is: Validate API responses and explicitly handle missing data before calculating health status. Relevant evidence: Inspect command return status, payload schema, missing fields, tracebacks and data freshness. The automation change must pass a preproduction test and leave a verifiable audit trail.
C:Verify the Guest Shell environment, mounted paths and supported data-transfer method rather than assuming shared filesystems. This concerns guest shell isolation, not on-box python exception handling.
Question 779
An automated UCS association binds a high-memory workload to a blade that lacks the required adapter capability. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What information should be inspected before the change is applied?
- Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding.
- Inspect server inventory, qualification criteria, pool membership and association failures.
- Inspect parent templates, derived profiles, policy inheritance and pending association changes.
- Inspect service-profile boot targets, FLOGI, active zones, array masking and target LUN visibility.
Explanation
Correct Answer
B:Inspect server inventory, qualification criteria, pool membership and association failures. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Pool qualification policies can restrict association based on compatible server hardware characteristics. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.
Incorrect Answers
A:Inspect vNIC fabric bindings, uplink port channels, failover policy and upstream switch forwarding. This concerns UCS fabric redundancy, not server pool qualification.
C:Inspect parent templates, derived profiles, policy inheritance and pending association changes. This concerns updating service-profile templates, not server pool qualification.
D:Inspect service-profile boot targets, FLOGI, active zones, array masking and target LUN visibility. This concerns SAN boot path policy, not server pool qualification.
Question 780
An administrator assumes every MDS image update is nondisruptive because the switch has redundant supervisors. A storage change board requires a traceable diagnosis before allowing further fabric changes. What is the strongest technical basis for the recommended action?
- NFS file access is controlled by network and export permissions, not Fibre Channel zoning.
- CRC and link-level errors can indicate transport impairment rather than a storage-array performance limitation.
- iSCSI uses IP transport and initiator-target session controls rather than Fibre Channel fabric login.
- SAN nondisruptive upgrade support depends on exact software path, hardware redundancy and active feature constraints.
Explanation
Correct Answer
D:SAN nondisruptive upgrade support depends on exact software path, hardware redundancy and active feature constraints. A storage change board requires a traceable diagnosis before allowing further fabric changes.
Incorrect Answers
A:NFS file access is controlled by network and export permissions, not Fibre Channel zoning. This concerns nfs export permissions, not mds nondisruptive upgrade planning.
B:CRC and link-level errors can indicate transport impairment rather than a storage-array performance limitation. This concerns SAN port error telemetry, not mds nondisruptive upgrade planning.
C:iSCSI uses IP transport and initiator-target session controls rather than Fibre Channel fabric login. This concerns iscsi target discovery, not mds nondisruptive upgrade planning.