Question 720
A Linux utility installed in the NX-OS Guest Shell cannot find a file that an operator placed on a different management workstation. The automation change must pass a preproduction test and leave a verifiable audit trail. What should the engineer collect before ruling out other causes?
- Inspect version-controlled declarations, current plan, state backend locks and out-of-band change record.
- Inspect response status and body, user roles, NX-API feature state and endpoint documentation.
- Inspect Guest Shell availability, mount mappings, file locations, network access and executed command output.
- Inspect job definition, scheduler timetable, execution status and change-window policy.
Explanation
Correct Answer
C:Inspect Guest Shell availability, mount mappings, file locations, network access and executed command output. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Guest Shell provides a separate Linux execution environment with its own file and permission context. The automation change must pass a preproduction test and leave a verifiable audit trail.
Incorrect Answers
A:Inspect version-controlled declarations, current plan, state backend locks and out-of-band change record. This concerns terraform plan and state, not guest shell isolation.
B:Inspect response status and body, user roles, NX-API feature state and endpoint documentation. That response is associated with nx-api request authorization rather than the specific guest shell isolation condition described here. For the stated failure, the preferred action is: Verify the Guest Shell environment, mounted paths and supported data-transfer method rather than assuming shared filesystems. Relevant evidence: Inspect Guest Shell availability, mount mappings, file locations, network access and executed command output. The automation change must pass a preproduction test and leave a verifiable audit trail.
D:Inspect job definition, scheduler timetable, execution status and change-window policy. That response is associated with nx-os scheduler jobs rather than the specific guest shell isolation condition described here. For the stated failure, the preferred action is: Verify the Guest Shell environment, mounted paths and supported data-transfer method rather than assuming shared filesystems. Relevant evidence: Inspect Guest Shell availability, mount mappings, file locations, network access and executed command output. The automation change must pass a preproduction test and leave a verifiable audit trail.
Question 721
A hypervisor installation leaves a virtual media image first in a UCS boot policy, causing repeated setup after power cycles. Operations is validating the host before approving production workload placement. Which test result best demonstrates restoration of the intended behavior?
- Each upgraded host returns healthy while the cluster continues meeting its availability objectives.
- Only the approved profile scope receives the tested update, with unrelated services preserved.
- The host starts from its approved production device through repeated controlled reboots.
- The workload profile attaches only to blades meeting the declared capacity and adapter criteria.
Explanation
Correct Answer
C:The host starts from its approved production device through repeated controlled reboots. This result tests the original failure rather than reporting merely that the configuration command was accepted. A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:Each upgraded host returns healthy while the cluster continues meeting its availability objectives. This concerns UCS firmware change sequencing, not boot order and removable media.
B:Only the approved profile scope receives the tested update, with unrelated services preserved. That response is associated with updating service-profile templates rather than the specific boot order and removable media condition described here. For the stated failure, the preferred action is: Restore the intended production boot-device order and detach temporary install media from the active policy. Relevant evidence: Inspect effective boot order, mapped virtual media state and host boot history. Operations is validating the host before approving production workload placement.
D:The workload profile attaches only to blades meeting the declared capacity and adapter criteria. That response is associated with server pool qualification rather than the specific boot order and removable media condition described here. For the stated failure, the preferred action is: Restore the intended production boot-device order and detach temporary install media from the active policy. Relevant evidence: Inspect effective boot order, mapped virtual media state and host boot history. Operations is validating the host before approving production workload placement.
Question 722
An administrator can see one domain in Intersight but cannot create profiles for a different business unit's assigned equipment. Operations is validating the host before approving production workload placement. Why is the targeted engineering response justified in this situation?
- UCS-X in Intersight Managed Mode uses Intersight-defined policies and profiles rather than unmodified UCS Manager assumptions.
- Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably.
- Intersight resource assignment and RBAC limit which infrastructure objects and policies an administrator can manage.
- Intersight Managed Mode applies shared domain-level fabric configuration through domain profiles and associated policies.
Explanation
Correct Answer
C:Intersight resource assignment and RBAC limit which infrastructure objects and policies an administrator can manage. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:UCS-X in Intersight Managed Mode uses Intersight-defined policies and profiles rather than unmodified UCS Manager assumptions. That response is associated with ucs-x intersight managed mode rather than the specific intersight organization scope condition described here. For the stated failure, the preferred action is: Check organization membership and resource-group scope before broadening permissions globally. Relevant evidence: Inspect resource groups, organizations, assigned roles and actual inventory associations. Operations is validating the host before approving production workload placement.
B:Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably. This concerns wwpn pool allocation, not intersight organization scope.
D:Intersight Managed Mode applies shared domain-level fabric configuration through domain profiles and associated policies. That response is associated with intersight domain profile rather than the specific intersight organization scope condition described here. For the stated failure, the preferred action is: Check organization membership and resource-group scope before broadening permissions globally. Relevant evidence: Inspect resource groups, organizations, assigned roles and actual inventory associations. Operations is validating the host before approving production workload placement.
Question 723
A cloning operation for storage-connected service profiles risks assigning previously reserved WWPNs to replacement blades. Operations is validating the host before approving production workload placement. Which limitation prevents the team from overgeneralizing this result?
- A storage-array LUN mapping cannot make an offline UCS SAN uplink carry the vHBA frames.
- A unique server serial number does not replace unique Fibre Channel initiator identifiers.
- Global administrator access is unnecessary when scoped resource assignment solves the visibility issue.
- An FC link up indication alone cannot prove that the boot LUN is authorized and reachable.
Explanation
Correct Answer
B:A unique server serial number does not replace unique Fibre Channel initiator identifiers. Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:A storage-array LUN mapping cannot make an offline UCS SAN uplink carry the vHBA frames. That response is associated with san connectivity from blade chassis rather than the specific wwpn pool allocation condition described here. For the stated failure, the preferred action is: Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities. Relevant evidence: Inspect WWPN pool reservations, active vHBA identities, fabric login records and zoning references. Operations is validating the host before approving production workload placement.
C:Global administrator access is unnecessary when scoped resource assignment solves the visibility issue. This concerns intersight organization scope, not wwpn pool allocation.
D:An FC link up indication alone cannot prove that the boot LUN is authorized and reachable. That response is associated with san boot path policy rather than the specific wwpn pool allocation condition described here. For the stated failure, the preferred action is: Assign WWPNs from a nonoverlapping pool and validate effective per-fabric vHBA identities. Relevant evidence: Inspect WWPN pool reservations, active vHBA identities, fabric login records and zoning references. Operations is validating the host before approving production workload placement.
Question 724
A design team labels a private on-premises cloud and a separately operated public cloud as one private deployment even though workloads move between them. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which qualification should the change record include?
- A working keepalive is not a replacement data path for the vPC peer-link.
- An overall green dashboard health score does not guarantee all application paths perform normally.
- Using a VPN between environments alone is not enough to prove application portability or cloud-service characteristics.
- LACP negotiation cannot compensate for incompatible allowed VLAN or switching-mode settings.
Explanation
Correct Answer
C:Using a VPN between environments alone is not enough to prove application portability or cloud-service characteristics. Hybrid cloud combines distinct cloud infrastructures linked to support data and application portability. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.
Incorrect Answers
A:A working keepalive is not a replacement data path for the vPC peer-link. This concerns vpc peer-link recovery, not hybrid cloud model classification.
B:An overall green dashboard health score does not guarantee all application paths perform normally. This concerns nexus dashboard fabric visibility, not hybrid cloud model classification.
D:LACP negotiation cannot compensate for incompatible allowed VLAN or switching-mode settings. This concerns lacp member mismatch, not hybrid cloud model classification.
Question 725
A cloning operation for storage-connected service profiles risks assigning previously reserved WWPNs to replacement blades. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which limitation prevents the team from overgeneralizing this result?
- A storage-array LUN mapping cannot make an offline UCS SAN uplink carry the vHBA frames.
- An FC link up indication alone cannot prove that the boot LUN is authorized and reachable.
- A high-availability label does not guarantee there is sufficient spare capacity for concurrent outages.
- A unique server serial number does not replace unique Fibre Channel initiator identifiers.
Explanation
Correct Answer
D:A unique server serial number does not replace unique Fibre Channel initiator identifiers. Unique WWPN identities let SAN switches and arrays distinguish initiators and apply zoning and masking predictably. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.
Incorrect Answers
A:A storage-array LUN mapping cannot make an offline UCS SAN uplink carry the vHBA frames. This concerns SAN connectivity from blade chassis, not wwpn pool allocation.
B:An FC link up indication alone cannot prove that the boot LUN is authorized and reachable. This concerns SAN boot path policy, not wwpn pool allocation.
C:A high-availability label does not guarantee there is sufficient spare capacity for concurrent outages. This concerns UCS firmware change sequencing, not wwpn pool allocation.
Question 726
A blade's vNIC sees intermittent retransmissions after a QoS change, but ordinary UCS counters lack per-packet context. Operations is validating the host before approving production workload placement. What should the engineer do first to address the observed failure?
- Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path.
- Inspect chassis power, fan and thermal faults before changing application performance settings.
- Create and secure an appropriate management configuration backup before a major maintenance operation.
- Correlate the adapter's hardware fault and affected chassis events before modifying host compute policy.
Explanation
Correct Answer
A:Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path. Packet replication can reveal TCP and frame-level behavior that interface counters summarize only coarsely. Operations is validating the host before approving production workload placement.
Incorrect Answers
B:Inspect chassis power, fan and thermal faults before changing application performance settings. That response is associated with chassis power and thermal monitoring rather than the specific compute traffic span condition described here. For the stated failure, the preferred action is: Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path. Relevant evidence: Inspect capture-point support, vNIC policy, frame timestamps, queue counters and retransmission patterns. Operations is validating the host before approving production workload placement.
C:Create and secure an appropriate management configuration backup before a major maintenance operation. This concerns UCS management backup, not compute traffic span.
D:Correlate the adapter's hardware fault and affected chassis events before modifying host compute policy. That response is associated with intersight alert triage rather than the specific compute traffic span condition described here. For the stated failure, the preferred action is: Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path. Relevant evidence: Inspect capture-point support, vNIC policy, frame timestamps, queue counters and retransmission patterns. Operations is validating the host before approving production workload placement.
Question 727
After staging a server firmware upgrade, the adapter and BIOS target versions differ from the supported hardware compatibility matrix. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What post-change observation gives the strongest evidence of success?
- Applied firmware aligns with approved compatibility targets and the host remains healthy after validation.
- The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths.
- Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct.
- The blade discovers the intended boot LUN and boots after a controlled restart.
Explanation
Correct Answer
A:Applied firmware aligns with approved compatibility targets and the host remains healthy after validation. This result tests the original failure rather than reporting merely that the configuration command was accepted. A server and adapter firmware combination must be supported for its hardware and operating environment. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.
Incorrect Answers
B:The expected WWPN performs fabric login on the correct VSAN and sees authorized storage paths. This concerns SAN connectivity from blade chassis, not UCS firmware compatibility.
C:Each replacement initiator logs in with the intended unique WWPN and its storage presentation remains correct. This concerns wwpn pool allocation, not UCS firmware compatibility.
D:The blade discovers the intended boot LUN and boots after a controlled restart. This concerns SAN boot path policy, not UCS firmware compatibility.
Question 728
An NX-OS switch logs an uplink failure but an EEM policy intended to notify the NOC never triggers. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. How should the implementation be validated against the original failure?
- The utility reads the intended local input under the approved Guest Shell permissions and completes the task.
- The job executes at the approved time and records the expected result without unplanned repeats.
- A controlled matching test message invokes the intended notification exactly once and produces an audit record.
- Tests with absent fields return an explicit unknown/error outcome rather than a fabricated healthy metric.
Explanation
Correct Answer
C:A controlled matching test message invokes the intended notification exactly once and produces an audit record. This result tests the original failure rather than reporting merely that the configuration command was accepted. Embedded Event Manager runs configured actions in response to matching local events and authorization constraints. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.
Incorrect Answers
A:The utility reads the intended local input under the approved Guest Shell permissions and completes the task. This concerns guest shell isolation, not eem syslog-triggered remediation.
B:The job executes at the approved time and records the expected result without unplanned repeats. This concerns nx-os scheduler jobs, not eem syslog-triggered remediation.
D:Tests with absent fields return an explicit unknown/error outcome rather than a fabricated healthy metric. This concerns on-box python exception handling, not eem syslog-triggered remediation.
Question 729
A fabric orchestrator pushes a template to the wrong Nexus Dashboard site after an inventory tag was copied between environments. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. What should the engineer collect before ruling out other causes?
- Inspect target site IDs, inventory assignments, proposed diffs and authorizations.
- Inspect repository history, credential storage, role scope, token rotation and execution audit logs.
- Inspect response status and body, user roles, NX-API feature state and endpoint documentation.
- Inspect DHCP offers, bootstrap URL, DNS/routing, file server availability and switch console logs.
Explanation
Correct Answer
A:Inspect target site IDs, inventory assignments, proposed diffs and authorizations. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Shared management APIs need explicit target selection; ambiguous tags can misdirect otherwise syntactically valid changes. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.
Incorrect Answers
B:Inspect repository history, credential storage, role scope, token rotation and execution audit logs. This concerns powershell api token security, not nexus dashboard automation scope.
C:Inspect response status and body, user roles, NX-API feature state and endpoint documentation. This concerns nx-api request authorization, not nexus dashboard automation scope.
D:Inspect DHCP offers, bootstrap URL, DNS/routing, file server availability and switch console logs. This concerns poap bootstrap dependencies, not nexus dashboard automation scope.
Question 730
After a hypervisor migration, ACI virtual machine endpoints do not appear in the intended EPG although the VLAN already exists in the fabric. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which result would best confirm that the remediation worked?
- Captured packets reproduce the reset sequence and identify which endpoint initiated it.
- Virtual endpoints are learned in the intended EPG and their traffic follows its applied contracts.
- The leaf appears as a registered healthy fabric member with the expected role and adjacency.
- The target encapsulation is programmed on the intended port and endpoint learning succeeds.
Explanation
Correct Answer
B:Virtual endpoints are learned in the intended EPG and their traffic follows its applied contracts. This result tests the original failure rather than reporting merely that the configuration command was accepted. ACI VMM integration maps VM networks and EPGs through the virtualized domain to appropriate fabric policy. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.
Incorrect Answers
A:Captured packets reproduce the reset sequence and identify which endpoint initiated it. This concerns span packet-level diagnosis, not aci vmm association.
C:The leaf appears as a registered healthy fabric member with the expected role and adjacency. This concerns aci fabric discovery, not aci vmm association.
D:The target encapsulation is programmed on the intended port and endpoint learning succeeds. This concerns aci access policy chain, not aci vmm association.
Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests