Question 350
A Nexus switch upgrade has been described as nondisruptive, but the running hardware and target image are not confirmed as ISSU compatible. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence. Which controlled change is most appropriate given the evidence?
- Advertise and verify the VTEP source-loopback reachability in the underlay routing domain.
- Run the supported compatibility and impact checks and plan an outage if an ISSU path is not qualified.
- Correct the L3 VNI and tenant VRF association and check EVPN route import/export on participating VTEPs.
- Confirm the designated root and spanning-tree role before changing a port that is intentionally blocking a loop.
Explanation
Correct Answer
B:Run the supported compatibility and impact checks and plan an outage if an ISSU path is not qualified. Nondisruptive software upgrade support is platform, topology and image-path dependent and must be verified. A second maintenance window is approaching, and the engineer must confirm the same failure mode using current device evidence.
Incorrect Answers
A:Advertise and verify the VTEP source-loopback reachability in the underlay routing domain. This concerns vxlan vtep underlay reachability, not nexus issu eligibility.
C:Correct the L3 VNI and tenant VRF association and check EVPN route import/export on participating VTEPs. This concerns evpn vni-to-vrf mapping, not nexus issu eligibility.
D:Confirm the designated root and spanning-tree role before changing a port that is intentionally blocking a loop. This concerns rstp blocked uplink, not nexus issu eligibility.
Question 351
A service-profile template update adds a workload VLAN but newly associated blades cannot send tagged frames for that network. Operations is validating the host before approving production workload placement. What is the strongest technical basis for the recommended action?
- Logical dual vNIC definitions provide resilience only when each has a functioning independent physical fabric path.
- A vNIC may be configured for a VLAN that the fabric and upstream trunks still do not carry.
- The blade chassis depends on a healthy IOM and fabric-interconnect management path to discover and service blades.
- UCS identity pools must avoid reuse because overlapping MAC addresses can cause Layer 2 instability and confusing endpoint learning.
Explanation
Correct Answer
B:A vNIC may be configured for a VLAN that the fabric and upstream trunks still do not carry. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:Logical dual vNIC definitions provide resilience only when each has a functioning independent physical fabric path. That response is associated with ucs fabric redundancy rather than the specific ucs vlan pool and template condition described here. For the stated failure, the preferred action is: Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path. Relevant evidence: Inspect effective vNIC templates, VLAN object assignments, LAN uplink trunk allowances and fault logs. Operations is validating the host before approving production workload placement.
C:The blade chassis depends on a healthy IOM and fabric-interconnect management path to discover and service blades. This concerns UCS blade chassis IOM discovery, not UCS VLAN pool and template.
D:UCS identity pools must avoid reuse because overlapping MAC addresses can cause Layer 2 instability and confusing endpoint learning. That response is associated with ucs mac pool uniqueness rather than the specific ucs vlan pool and template condition described here. For the stated failure, the preferred action is: Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path. Relevant evidence: Inspect effective vNIC templates, VLAN object assignments, LAN uplink trunk allowances and fault logs. Operations is validating the host before approving production workload placement.
Question 352
Updating a UCS updating-template appears to change vNIC settings on more blades than intended. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. Which technical principle best explains the recommended response?
- A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur.
- Pool qualification policies can restrict association based on compatible server hardware characteristics.
- Updating templates can propagate modifications to associated service profiles; change impact depends on associations.
- A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts.
Explanation
Correct Answer
C:Updating templates can propagate modifications to associated service profiles; change impact depends on associations. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.
Incorrect Answers
A:A blade vHBA needs an operational fabric path and correct VSAN association before a fabric login can occur. This concerns SAN connectivity from blade chassis, not updating service-profile templates.
B:Pool qualification policies can restrict association based on compatible server hardware characteristics. This concerns server pool qualification, not updating service-profile templates.
D:A persistent virtual-media boot entry can supersede the production storage or disk target on later restarts. This concerns boot order and removable media, not updating service-profile templates.
Question 353
A new MDS FC port channel comes up with only one member while the remaining ports are suspended. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. Why is the targeted engineering response justified in this situation?
- Cisco Fabric Services can distribute feature configuration among fabric switches, subject to feature-specific rules.
- An initiator must complete fabric login and receive an FCID before normal fabric services can identify it.
- Fibre Channel port channels bundle compatible physical links; inconsistent member configuration can suspend interfaces.
- FCID addressing includes a domain component, and domain conflicts can prevent stable fabric formation.
Explanation
Correct Answer
C:Fibre Channel port channels bundle compatible physical links; inconsistent member configuration can suspend interfaces. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.
Incorrect Answers
A:Cisco Fabric Services can distribute feature configuration among fabric switches, subject to feature-specific rules. This concerns cisco fabric services distribution, not fibre channel port-channel consistency.
B:An initiator must complete fabric login and receive an FCID before normal fabric services can identify it. This concerns fibre channel fabric login, not fibre channel port-channel consistency.
D:FCID addressing includes a domain component, and domain conflicts can prevent stable fabric formation. This concerns fcid and domain id stability, not fibre channel port-channel consistency.
Question 354
A network inventory script reports only the first hundred switches even though Nexus Dashboard shows more devices. The automation change must pass a preproduction test and leave a verifiable audit trail. What post-change observation gives the strongest evidence of success?
- A second run against an unchanged fabric reports no material differences and service tests remain stable.
- The network change reduces packet loss and congestion while measured training-step throughput improves.
- The device retrieves verified artifacts and applies the approved initial configuration successfully.
- The completed script retrieves the full authorized inventory across every page with no repeated identifiers.
Explanation
Correct Answer
D:The completed script retrieves the full authorized inventory across every page with no repeated identifiers. This result tests the original failure rather than reporting merely that the configuration command was accepted. Paginated REST endpoints may return only a subset of objects unless clients follow continuation information. The automation change must pass a preproduction test and leave a verifiable audit trail.
Incorrect Answers
A:A second run against an unchanged fabric reports no material differences and service tests remain stable. That response is associated with ansible idempotent templates rather than the specific python api pagination condition described here. For the stated failure, the preferred action is: Implement documented pagination and response-error handling in the inventory API client. Relevant evidence: Inspect response metadata, page limits, next tokens, error responses and known inventory counts. The automation change must pass a preproduction test and leave a verifiable audit trail.
B:The network change reduces packet loss and congestion while measured training-step throughput improves. This concerns ai cluster network congestion, not python api pagination.
C:The device retrieves verified artifacts and applies the approved initial configuration successfully. That response is associated with poap bootstrap dependencies rather than the specific python api pagination condition described here. For the stated failure, the preferred action is: Implement documented pagination and response-error handling in the inventory API client. Relevant evidence: Inspect response metadata, page limits, next tokens, error responses and known inventory counts. The automation change must pass a preproduction test and leave a verifiable audit trail.
Question 355
Two workloads reside in the same IP subnet but policy requires stricter isolation for only a tagged set of VMs. Security engineering must restore the approved service without relaxing unrelated protection. What information should be inspected before the change is applied?
- Inspect TACACS+ reachability, AAA method lists, local credentials and access accounting.
- Inspect DAI drop counters, DHCP snooping binding table, static host assignments and ARP inspection logs.
- Inspect VM attributes, uSeg EPG selectors, endpoint placement and resulting enforced contracts.
- Inspect EPG bindings, contracts, subject filters, provider-consumer association and zoning rules.
Explanation
Correct Answer
C:Inspect VM attributes, uSeg EPG selectors, endpoint placement and resulting enforced contracts. These records help distinguish the suspected failure from a superficially similar fault before modifying production. Microsegmentation can classify subsets of endpoints beyond broad subnet grouping and apply finer-grained controls. Security engineering must restore the approved service without relaxing unrelated protection.
Incorrect Answers
A:Inspect TACACS+ reachability, AAA method lists, local credentials and access accounting. This concerns centralized AAA fallback, not aci microsegmentation selector.
B:Inspect DAI drop counters, DHCP snooping binding table, static host assignments and ARP inspection logs. That response is associated with dynamic arp inspection source of truth rather than the specific aci microsegmentation selector condition described here. For the stated failure, the preferred action is: Use supported ACI microsegmentation classification and policy to distinguish the tagged workloads. Relevant evidence: Inspect VM attributes, uSeg EPG selectors, endpoint placement and resulting enforced contracts. Security engineering must restore the approved service without relaxing unrelated protection.
D:Inspect EPG bindings, contracts, subject filters, provider-consumer association and zoning rules. That response is associated with aci inter-epg contract rather than the specific aci microsegmentation selector condition described here. For the stated failure, the preferred action is: Use supported ACI microsegmentation classification and policy to distinguish the tagged workloads. Relevant evidence: Inspect VM attributes, uSeg EPG selectors, endpoint placement and resulting enforced contracts. Security engineering must restore the approved service without relaxing unrelated protection.
Question 356
A UCS fabric interconnect in NPV mode can establish an FC physical uplink but attached server vHBAs cannot complete login. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN. What information should be inspected before the change is applied?
- Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs.
- Inspect target portal IPs, IQN access rules, CHAP policy, TCP reachability and multipath sessions.
- Inspect alias database, recorded target WWPNs, zones using the alias and change approvals.
- Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs.
Explanation
Correct Answer
D:Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. NPV proxies initiator logins through an upstream fabric switch, which must support the required virtual-port logins. During the next path-failover exercise, the SAN team must confirm the same dependency on the affected VSAN.
Incorrect Answers
A:Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. This concerns VSAN isolation, not npv uplink fabric services.
B:Inspect target portal IPs, IQN access rules, CHAP policy, TCP reachability and multipath sessions. This concerns iscsi target discovery, not npv uplink fabric services.
C:Inspect alias database, recorded target WWPNs, zones using the alias and change approvals. This concerns device alias maintenance, not npv uplink fabric services.
Question 357
A service-profile template update adds a workload VLAN but newly associated blades cannot send tagged frames for that network. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state. What should the engineer do first to address the observed failure?
- Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment.
- Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path.
- Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs.
- Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path.
Explanation
Correct Answer
D:Align the vNIC template VLAN membership and upstream VLAN allowance across the chosen fabric path. A vNIC may be configured for a VLAN that the fabric and upstream trunks still do not carry. The issue reappears on a second managed host, so the team is checking its effective profiles and hardware state.
Incorrect Answers
A:Separate the relevant MAC pool ranges and confirm all instantiated identities are unique before attachment. This concerns UCS mac pool uniqueness, not UCS VLAN pool and template.
B:Configure an authorized traffic mirror or supported capture point to observe the affected vNIC path. This concerns compute traffic span, not UCS VLAN pool and template.
C:Validate that fabric A and fabric B interfaces have independent working uplinks and correctly bound vNICs. This concerns UCS fabric redundancy, not UCS VLAN pool and template.
Question 358
A maintenance script needs to run on a fixed schedule but an engineer proposes an EEM syslog trigger instead. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition. What post-change observation gives the strongest evidence of success?
- A controlled matching test message invokes the intended notification exactly once and produces an audit record.
- The utility reads the intended local input under the approved Guest Shell permissions and completes the task.
- The completed script retrieves the full authorized inventory across every page with no repeated identifiers.
- The job executes at the approved time and records the expected result without unplanned repeats.
Explanation
Correct Answer
D:The job executes at the approved time and records the expected result without unplanned repeats. This result tests the original failure rather than reporting merely that the configuration command was accepted. Scheduled tasks follow time-based execution rather than requiring a spontaneous syslog event to fire. A scheduled deployment is pending, and the engineer must validate how the script handles this failure condition.
Incorrect Answers
A:A controlled matching test message invokes the intended notification exactly once and produces an audit record. This concerns eem syslog-triggered remediation, not nx-os scheduler jobs.
B:The utility reads the intended local input under the approved Guest Shell permissions and completes the task. This concerns guest shell isolation, not nx-os scheduler jobs.
C:The completed script retrieves the full authorized inventory across every page with no repeated identifiers. This concerns python api pagination, not nx-os scheduler jobs.
Question 359
An automated UCS association binds a high-memory workload to a blade that lacks the required adapter capability. Operations is validating the host before approving production workload placement. Why is the targeted engineering response justified in this situation?
- SAN boot requires all of the initiator, fabric zoning, target presentation and boot policy to agree.
- Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure.
- Pool qualification policies can restrict association based on compatible server hardware characteristics.
- Updating templates can propagate modifications to associated service profiles; change impact depends on associations.
Explanation
Correct Answer
C:Pool qualification policies can restrict association based on compatible server hardware characteristics. Operations is validating the host before approving production workload placement.
Incorrect Answers
A:SAN boot requires all of the initiator, fabric zoning, target presentation and boot policy to agree. That response is associated with san boot path policy rather than the specific server pool qualification condition described here. For the stated failure, the preferred action is: Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies. Relevant evidence: Inspect server inventory, qualification criteria, pool membership and association failures. Operations is validating the host before approving production workload placement.
B:Restoring UCS management state can reintroduce policy and identity definitions that differ from current infrastructure. This concerns UCS restore integrity, not server pool qualification.
D:Updating templates can propagate modifications to associated service profiles; change impact depends on associations. That response is associated with updating service-profile templates rather than the specific server pool qualification condition described here. For the stated failure, the preferred action is: Correct server-pool qualifications and service-profile placement criteria for the workload's hardware dependencies. Relevant evidence: Inspect server inventory, qualification criteria, pool membership and association failures. Operations is validating the host before approving production workload placement.
Question 360
A UCS fabric interconnect in NPV mode can establish an FC physical uplink but attached server vHBAs cannot complete login. A storage change board requires a traceable diagnosis before allowing further fabric changes. What information should be inspected before the change is applied?
- Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs.
- Inspect alias database, recorded target WWPNs, zones using the alias and change approvals.
- Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs.
- Inspect CFS peers, lock ownership, pending changes, feature status and activation records.
Explanation
Correct Answer
A:Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. These records help distinguish the suspected failure from a superficially similar fault before modifying production. NPV proxies initiator logins through an upstream fabric switch, which must support the required virtual-port logins. A storage change board requires a traceable diagnosis before allowing further fabric changes.
Incorrect Answers
B:Inspect alias database, recorded target WWPNs, zones using the alias and change approvals. That response is associated with device alias maintenance rather than the specific npv uplink fabric services condition described here. For the stated failure, the preferred action is: Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. Relevant evidence: Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. A storage change board requires a traceable diagnosis before allowing further fabric changes.
C:Inspect interface-to-VSAN membership, active zonesets, fabric IDs and authorized inter-VSAN designs. That response is associated with vsan isolation rather than the specific npv uplink fabric services condition described here. For the stated failure, the preferred action is: Confirm upstream NPIV support and the NPV uplink VSAN association before modifying host zoning. Relevant evidence: Inspect upstream NPIV configuration, NPV status, uplink VSAN, FLOGI database and server WWPNs. A storage change board requires a traceable diagnosis before allowing further fabric changes.
D:Inspect CFS peers, lock ownership, pending changes, feature status and activation records. This concerns cisco fabric services distribution, not npv uplink fabric services.
Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests