Question 690
For a FortiSwitch deployment, the root cause is confirmed as: An IP ping cannot replace switch forwarding-table evidence. The incident was: The administrator needs to learn which VLAN a specific endpoint MAC occupies. Which next operational step is MOST appropriate for this confirmed issue?
- Correlate discards, errors, utilization and packet observations on that port
- Inspect the FortiSwitch MAC address table for the relevant VLAN and port
- View PoE consumption and power-supply status for affected ports
- Compare intended controller configuration, local state and reboot events
Explanation
Correct Answer
B:Inspect the FortiSwitch MAC address table for the relevant VLAN and port. It targets or investigates the confirmed mechanism (An IP ping cannot replace switch forwarding-table evidence). Verify the intended outcome against the evidence: The endpoint MAC maps to the expected source port and VLAN.
Incorrect Answers
A:Although Correlate discards, errors, utilization and packet observations on that port can be useful elsewhere, its prerequisite is the separate situation 'A performance alarm points to a single copper port with increasing discards'. Here the engineer must address "An IP ping cannot replace switch forwarding-table evidence" through the specified corrective action.
C:Choosing View PoE consumption and power-supply status for affected ports would alter another behavior, while "An IP ping cannot replace switch forwarding-table evidence" remains unchanged. It would not restore the result: "The endpoint MAC maps to the expected source port and VLAN".
D:The action 'Compare intended controller configuration, local state and reboot events' responds to 'A switch rebooted after maintenance but its new configuration disappeared', not the identified cause here: "An IP ping cannot replace switch forwarding-table evidence". That would leave the current acceptance test unmet.
Question 691
For the incident 'The administrator needs to learn which VLAN a specific endpoint MAC occupies', the approved corrective change is: Inspect the FortiSwitch MAC address table for the relevant VLAN and port. Which result would BEST demonstrate that the intended outcome has been achieved?
- The endpoint MAC maps to the expected source port and VLAN
- The required setting persists after a controlled restart
- The server-response path is identified without disabling snooping globally
- Expected peer chassis and port identifiers appear in supported inventory
Explanation
Correct Answer
A:The endpoint MAC maps to the expected source port and VLAN. This observable result demonstrates that the change 'Inspect the FortiSwitch MAC address table for the relevant VLAN and port' resolved the identified condition 'An IP ping cannot replace switch forwarding-table evidence'.
Incorrect Answers
B:The observation 'The required setting persists after a controlled restart' demonstrates recovery for 'A switch rebooted after maintenance but its new configuration disappeared', rather than showing that this incident reached "The endpoint MAC maps to the expected source port and VLAN".
C:The metric 'The server-response path is identified without disabling snooping globally' belongs to another network path. It would not prove the specified remediation corrected "An IP ping cannot replace switch forwarding-table evidence".
D:Even if Expected peer chassis and port identifiers appear in supported inventory, the confirmed condition "An IP ping cannot replace switch forwarding-table evidence" might remain. The intended acceptance evidence is "The endpoint MAC maps to the expected source port and VLAN".
Question 692
Before a similar FortiSwitch deployment, review this previous incident: The administrator needs to learn which VLAN a specific endpoint MAC occupies. Which preventive control MOST directly reduces recurrence of the underlying risk?
- Monitor cumulative PoE budget with capacity thresholds
- Back up approved configurations and verify controller sync before reboots
- Preserve known-good DHCP traffic captures for comparison
- Retain switch MAC-table snapshots for complex cutovers
Explanation
Correct Answer
D:Retain switch MAC-table snapshots for complex cutovers. This safeguard directly reduces recurrence of the condition 'An IP ping cannot replace switch forwarding-table evidence' while keeping unrelated controls in place.
Incorrect Answers
A:Using Monitor cumulative PoE budget with capacity thresholds here could leave the underlying weakness ("An IP ping cannot replace switch forwarding-table evidence") in place. The narrower preventive check is "Retain switch MAC-table snapshots for complex cutovers".
B:Back up approved configurations and verify controller sync before reboots is a control aimed at 'A switch rebooted after maintenance but its new configuration disappeared'. It would not directly prevent the identified recurrence risk ("An IP ping cannot replace switch forwarding-table evidence"); the appropriate safeguard is "Retain switch MAC-table snapshots for complex cutovers".
C:Preserve known-good DHCP traffic captures for comparison would be useful for Clients cannot get addresses and the switch port table shows requests but no DHCP replies, not for the recurrence risk associated with "An IP ping cannot replace switch forwarding-table evidence".
Question 693
In a FortiSwitchOS/FortiOS 7.6 network, the operator observes this incident: A switch rebooted after maintenance but its new configuration disappeared. Which configuration condition or investigative conclusion BEST fits the available facts?
- The available evidence must distinguish client requests from server response reachability
- Physical media degradation can exist while link state remains up
- An IP ping cannot replace switch forwarding-table evidence
- The effective configuration is not persisted or controller synchronization was overridden
Explanation
Correct Answer
D:The effective configuration is not persisted or controller synchronization was overridden. This is the relevant interpretation of the operating situation 'A switch rebooted after maintenance but its new configuration disappeared' and informs the next operational step: Compare intended controller configuration, local state and reboot events.
Incorrect Answers
A:The available evidence must distinguish client requests from server response reachability. That diagnosis fits the situation where clients cannot get addresses and the switch port table shows requests but no DHCP replies, but this incident is explained by the effective configuration is not persisted or controller synchronization was overridden.
B:Physical media degradation can exist while link state remains up could explain the distinct observation A fiber uplink is up but its CRC error counter increases every minute. It does not explain the affected device and settings here as specifically as "The effective configuration is not persisted or controller synchronization was overridden".
C:Consider An IP ping cannot replace switch forwarding-table evidence only when the evidence looks like The administrator needs to learn which VLAN a specific endpoint MAC occupies. Here the more applicable fault mechanism is "The effective configuration is not persisted or controller synchronization was overridden".
Question 694
For a FortiSwitch deployment, the root cause is confirmed as: The effective configuration is not persisted or controller synchronization was overridden. The incident was: A switch rebooted after maintenance but its new configuration disappeared. Which next operational step is MOST appropriate for this confirmed issue?
- Inspect per-port counters and scoped DHCP traffic captures at the appropriate uplink
- Inspect transceiver diagnostics, cable and FCS counters instead of changing routing
- Compare intended controller configuration, local state and reboot events
- Correlate discards, errors, utilization and packet observations on that port
Explanation
Correct Answer
C:Compare intended controller configuration, local state and reboot events. It targets or investigates the confirmed mechanism (The effective configuration is not persisted or controller synchronization was overridden). Verify the intended outcome against the evidence: The required setting persists after a controlled restart.
Incorrect Answers
A:Choosing Inspect per-port counters and scoped DHCP traffic captures at the appropriate uplink would alter another behavior, while "The effective configuration is not persisted or controller synchronization was overridden" remains unchanged. It would not restore the result: "The required setting persists after a controlled restart".
B:The action 'Inspect transceiver diagnostics, cable and FCS counters instead of changing routing' responds to 'A fiber uplink is up but its CRC error counter increases every minute', not the identified cause here: "The effective configuration is not persisted or controller synchronization was overridden". That would leave the current acceptance test unmet.
D:Although Correlate discards, errors, utilization and packet observations on that port can be useful elsewhere, its prerequisite is the separate situation 'A performance alarm points to a single copper port with increasing discards'. Here the engineer must address "The effective configuration is not persisted or controller synchronization was overridden" through the specified corrective action.
Question 695
For the incident 'A switch rebooted after maintenance but its new configuration disappeared', the approved corrective change is: Compare intended controller configuration, local state and reboot events. Which result would BEST demonstrate that the intended outcome has been achieved?
- The server-response path is identified without disabling snooping globally
- The required setting persists after a controlled restart
- Expected peer chassis and port identifiers appear in supported inventory
- The offending mechanism is isolated with time-aligned counters
Explanation
Correct Answer
B:The required setting persists after a controlled restart. This observable result demonstrates that the change 'Compare intended controller configuration, local state and reboot events' resolved the identified condition 'The effective configuration is not persisted or controller synchronization was overridden'.
Incorrect Answers
A:The metric 'The server-response path is identified without disabling snooping globally' belongs to another network path. It would not prove the specified remediation corrected "The effective configuration is not persisted or controller synchronization was overridden".
C:Even if 'Expected peer chassis and port identifiers appear in supported inventory' is true elsewhere, it is insufficient evidence for this case; the switch should demonstrate "The required setting persists after a controlled restart".
D:An observation of The offending mechanism is isolated with time-aligned counters relates to A performance alarm points to a single copper port with increasing discards; it does not confirm the required outcome "The required setting persists after a controlled restart".
Question 696
Before a similar FortiSwitch deployment, review this previous incident: A switch rebooted after maintenance but its new configuration disappeared. Which preventive control MOST directly reduces recurrence of the underlying risk?
- Back up approved configurations and verify controller sync before reboots
- Alert on abnormal MAC flaps and topology changes
- Monitor cumulative PoE budget with capacity thresholds
- Preserve known-good DHCP traffic captures for comparison
Explanation
Correct Answer
A:Back up approved configurations and verify controller sync before reboots. This safeguard directly reduces recurrence of the condition 'The effective configuration is not persisted or controller synchronization was overridden' while keeping unrelated controls in place.
Incorrect Answers
B:The safeguard 'Alert on abnormal MAC flaps and topology changes' addresses a different condition: network staff report repeated MAC moves between two ports during an outage. This deployment instead needs a control against "The effective configuration is not persisted or controller synchronization was overridden".
C:The control Monitor cumulative PoE budget with capacity thresholds mitigates the alternate case A managed switch intermittently loses access clients after a PoE budget peak; it does not prevent the current mechanism "The effective configuration is not persisted or controller synchronization was overridden".
D:Using Preserve known-good DHCP traffic captures for comparison here could leave the underlying weakness ("The effective configuration is not persisted or controller synchronization was overridden") in place. The narrower preventive check is "Back up approved configurations and verify controller sync before reboots".
Question 697
In a FortiSwitchOS/FortiOS 7.6 network, the operator observes this incident: A performance alarm points to a single copper port with increasing discards. Which configuration condition or investigative conclusion BEST fits the available facts?
- The fault may be port congestion, queue policy or physical errors instead of controller availability
- The available evidence must distinguish client requests from server response reachability
- An IP ping cannot replace switch forwarding-table evidence
- Power utilization and endpoint power negotiation require examination
Explanation
Correct Answer
A:The fault may be port congestion, queue policy or physical errors instead of controller availability. This is the relevant interpretation of the operating situation 'A performance alarm points to a single copper port with increasing discards' and informs the next operational step: Correlate discards, errors, utilization and packet observations on that port.
Incorrect Answers
B:The hypothesis The available evidence must distinguish client requests from server response reachability normally concerns Clients cannot get addresses and the switch port table shows requests but no DHCP replies. The present symptoms instead point to "The fault may be port congestion, queue policy or physical errors instead of controller availability".
C:An IP ping cannot replace switch forwarding-table evidence. That mechanism applies when the administrator needs to learn which VLAN a specific endpoint MAC occupies; the present fault instead points to the fault may be port congestion, queue policy or physical errors instead of controller availability.
D:Power utilization and endpoint power negotiation require examination. That diagnosis fits the situation where a managed switch intermittently loses access clients after a PoE budget peak, but this incident is explained by the fault may be port congestion, queue policy or physical errors instead of controller availability.
Question 698
For a FortiSwitch deployment, the root cause is confirmed as: The fault may be port congestion, queue policy or physical errors instead of controller availability. The incident was: A performance alarm points to a single copper port with increasing discards. Which next operational step is MOST appropriate for this confirmed issue?
- View PoE consumption and power-supply status for affected ports
- Compare intended controller configuration, local state and reboot events
- Inspect per-port counters and scoped DHCP traffic captures at the appropriate uplink
- Correlate discards, errors, utilization and packet observations on that port
Explanation
Correct Answer
D:Correlate discards, errors, utilization and packet observations on that port. It targets or investigates the confirmed mechanism (The fault may be port congestion, queue policy or physical errors instead of controller availability). Verify the intended outcome against the evidence: The offending mechanism is isolated with time-aligned counters.
Incorrect Answers
A:View PoE consumption and power-supply status for affected ports treats the separate issue A managed switch intermittently loses access clients after a PoE budget peak. This incident has a different established cause: "The fault may be port congestion, queue policy or physical errors instead of controller availability"; the alternative would miss the required change.
B:Although Compare intended controller configuration, local state and reboot events can be useful elsewhere, its prerequisite is the separate situation 'A switch rebooted after maintenance but its new configuration disappeared'. Here the engineer must address "The fault may be port congestion, queue policy or physical errors instead of controller availability" through the specified corrective action.
C:The alternative Inspect per-port counters and scoped DHCP traffic captures at the appropriate uplink addresses the different situation Clients cannot get addresses and the switch port table shows requests but no DHCP replies. That action would leave the confirmed mechanism "The fault may be port congestion, queue policy or physical errors instead of controller availability" unresolved here.
Question 699
For the incident 'A performance alarm points to a single copper port with increasing discards', the approved corrective change is: Correlate discards, errors, utilization and packet observations on that port. Which result would BEST demonstrate that the intended outcome has been achieved?
- Power alarms correlate with the client drops and cease after budget correction
- The required setting persists after a controlled restart
- The offending mechanism is isolated with time-aligned counters
- Expected peer chassis and port identifiers appear in supported inventory
Explanation
Correct Answer
C:The offending mechanism is isolated with time-aligned counters. This observable result demonstrates that the change 'Correlate discards, errors, utilization and packet observations on that port' resolved the identified condition 'The fault may be port congestion, queue policy or physical errors instead of controller availability'.
Incorrect Answers
A:Even if 'Power alarms correlate with the client drops and cease after budget correction' is true elsewhere, it is insufficient evidence for this case; the switch should demonstrate "The offending mechanism is isolated with time-aligned counters".
B:An observation of The required setting persists after a controlled restart relates to A switch rebooted after maintenance but its new configuration disappeared; it does not confirm the required outcome "The offending mechanism is isolated with time-aligned counters".
D:The metric 'Expected peer chassis and port identifiers appear in supported inventory' belongs to another network path. It would not prove the specified remediation corrected "The fault may be port congestion, queue policy or physical errors instead of controller availability".
Question 700
Before a similar FortiSwitch deployment, review this previous incident: A performance alarm points to a single copper port with increasing discards. Which preventive control MOST directly reduces recurrence of the underlying risk?
- Retain switch MAC-table snapshots for complex cutovers
- Record port health baselines and raise actionable trend alerts
- Alert on abnormal MAC flaps and topology changes
- Monitor cumulative PoE budget with capacity thresholds
Explanation
Correct Answer
B:Record port health baselines and raise actionable trend alerts. This safeguard directly reduces recurrence of the condition 'The fault may be port congestion, queue policy or physical errors instead of controller availability' while keeping unrelated controls in place.
Incorrect Answers
A:The control Retain switch MAC-table snapshots for complex cutovers mitigates the alternate case The administrator needs to learn which VLAN a specific endpoint MAC occupies; it does not prevent the current mechanism "The fault may be port congestion, queue policy or physical errors instead of controller availability".
C:Alert on abnormal MAC flaps and topology changes is a control aimed at 'Network staff report repeated MAC moves between two ports during an outage'. It would not directly prevent the identified recurrence risk ("The fault may be port congestion, queue policy or physical errors instead of controller availability"); the appropriate safeguard is "Record port health baselines and raise actionable trend alerts".
D:Monitor cumulative PoE budget with capacity thresholds would be useful for A managed switch intermittently loses access clients after a PoE budget peak, not for the recurrence risk associated with "The fault may be port congestion, queue policy or physical errors instead of controller availability".
Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests