Question 810
A service coordinator has THREE separate support tickets and needs the correct matching actions: A company phone joins a Wi-Fi SSID but cannot reach intranet apps because the network requires a managed certificate not installed on the device. A Bluetooth headset suddenly reconnects to a nearby tablet instead of the employee's phone, although both devices have used it previously. A tablet displays strong Wi-Fi signal but no internet access, and its assigned gateway is unreachable. Which response best addresses these needs?
- Install the approved enterprise wireless profile and certificate through device management; check active multipoint pairing and select the intended audio endpoint; and connect to a supported band or supply a 6 GHz-capable device.
- Install the approved enterprise wireless profile and certificate through device management; check active multipoint pairing and select the intended audio endpoint; and verify the Wi-Fi network's DHCP, router and gateway status rather than changing the tablet display.
- Connect to a supported band or supply a 6 GHz-capable device; check active multipoint pairing and select the intended audio endpoint; and verify the Wi-Fi network's DHCP, router and gateway status rather than changing the tablet display.
- Install the approved enterprise wireless profile and certificate through device management; connect to a supported band or supply a 6 GHz-capable device; and verify the Wi-Fi network's DHCP, router and gateway status rather than changing the tablet display.
Explanation
Correct Answer
B:For ticket (1), Network association and enterprise application authorization are separate access requirements. For ticket (2), Bluetooth accessories may retain multiple paired devices and connect to the wrong source. For ticket (3), A strong radio link does not guarantee an operational Layer 3 path.
Incorrect Answers
A:For ticket 3, verify the Wi-Fi network's DHCP, router and gateway status rather than changing the tablet display. A strong radio link does not guarantee an operational Layer 3 path.
C:For ticket 1, install the approved enterprise wireless profile and certificate through device management. Network association and enterprise application authorization are separate access requirements.
D:For ticket 2, check active multipoint pairing and select the intended audio endpoint. Bluetooth accessories may retain multiple paired devices and connect to the wrong source.
Question 811
An IT support worker is asked to resolve this case: A desktop begins showing random system crashes only after a third-party high-frequency memory profile is enabled. Which next step MOST directly resolves the reported condition?
- Replace or isolate the failing supported DIMM after confirming its slot and configuration.
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
- Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test.
Explanation
Correct Answer
D:Aggressive timings may destabilize the memory subsystem without any disk fault.
Incorrect Answers
A:Repeatable memory errors tied to one module indicate a likely hardware defect; aggressive timings may destabilize the memory subsystem without any disk fault.
B:Damaged power-regulation components can destabilize the platform and create a safety concern; aggressive timings may destabilize the memory subsystem without any disk fault.
C:Vibration-sensitive faults often indicate loose internal contacts rather than a background app; aggressive timings may destabilize the memory subsystem without any disk fault.
Question 812
A service bench observes this hardware or network symptom: A computer intermittently reboots after a module upgrade, and a memory diagnostic reports errors only with one new DIMM installed. What should the support specialist recommend FIRST within the stated limits?
- Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test.
- Replace or isolate the failing supported DIMM after confirming its slot and configuration.
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
Explanation
Correct Answer
C:Repeatable memory errors tied to one module indicate a likely hardware defect.
Incorrect Answers
A:Reseat the supported memory and inspect the retention clips for movement would not replace or isolate the failing supported DIMM after confirming its slot and configuration.
B:Revert to supported memory settings and run a controlled RAM stability test would not replace or isolate the failing supported DIMM after confirming its slot and configuration.
D:Stopping normal use and arrange system-board replacement or qualified repair rather than continued stress testing would not replace or isolate the failing supported DIMM after confirming its slot and configuration.
Question 813
During a controlled office IT maintenance window, the technician notes: An office workstation produces spontaneous crashes and visible swollen capacitors are found on the motherboard. What is the MOST appropriate technician action?
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
- Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test.
- Replace or isolate the failing supported DIMM after confirming its slot and configuration.
Explanation
Correct Answer
A:Damaged power-regulation components can destabilize the platform and create a safety concern.
Incorrect Answers
B:Reseat the supported memory and inspect the retention clips for movement would not stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
C:Revert to supported memory settings and run a controlled RAM stability test would not stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
D:Replacing or isolate the failing supported DIMM after confirming its slot and configuration would not stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
Question 814
A support case documents the following situation: A notebook freezes when moved, but remains stable on a desk; its removable RAM has not been secured after service. Which response BEST addresses the actual cause or requirement?
- Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test.
- Replace or isolate the failing supported DIMM after confirming its slot and configuration.
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
Explanation
Correct Answer
A:Vibration-sensitive faults often indicate loose internal contacts rather than a background app.
Incorrect Answers
B:Aggressive timings may destabilize the memory subsystem without any disk fault; vibration-sensitive faults often indicate loose internal contacts rather than a background app.
C:Repeatable memory errors tied to one module indicate a likely hardware defect; vibration-sensitive faults often indicate loose internal contacts rather than a background app.
D:Damaged power-regulation components can destabilize the platform and create a safety concern; vibration-sensitive faults often indicate loose internal contacts rather than a background app.
Question 815
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A desktop begins showing random system crashes only after a third-party high-frequency memory profile is enabled. A computer intermittently reboots after a module upgrade, and a memory diagnostic reports errors only with one new DIMM installed. Which course of action addresses the stated issues?
- Revert to supported memory settings and run a controlled RAM stability test; replace or isolate the failing supported DIMM after confirming its slot and configuration.
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing; replace or isolate the failing supported DIMM after confirming its slot and configuration.
- Revert to supported memory settings and run a controlled RAM stability test; Reseat the supported memory and inspect the retention clips for movement.
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing; Reseat the supported memory and inspect the retention clips for movement.
Explanation
Correct Answer
A:For ticket (1), Aggressive timings may destabilize the memory subsystem without any disk fault. For ticket (2), Repeatable memory errors tied to one module indicate a likely hardware defect.
Incorrect Answers
B:For ticket 1, revert to supported memory settings and run a controlled RAM stability test. Aggressive timings may destabilize the memory subsystem without any disk fault.
C:For ticket 2, replace or isolate the failing supported DIMM after confirming its slot and configuration. Repeatable memory errors tied to one module indicate a likely hardware defect.
D:For ticket 1, revert to supported memory settings and run a controlled RAM stability test. Aggressive timings may destabilize the memory subsystem without any disk fault. For ticket 2, replace or isolate the failing supported DIMM after confirming its slot and configuration. Repeatable memory errors tied to one module indicate a likely hardware defect.
Question 816
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A desktop begins showing random system crashes only after a third-party high-frequency memory profile is enabled. An office workstation produces spontaneous crashes and visible swollen capacitors are found on the motherboard. Which response best addresses these needs?
- Replace or isolate the failing supported DIMM after confirming its slot and configuration; stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
- Revert to supported memory settings and run a controlled RAM stability test; Reseat the supported memory and inspect the retention clips for movement.
- Replace or isolate the failing supported DIMM after confirming its slot and configuration; Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test; stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
Explanation
Correct Answer
D:For ticket (1), Aggressive timings may destabilize the memory subsystem without any disk fault. For ticket (2), Damaged power-regulation components can destabilize the platform and create a safety concern.
Incorrect Answers
A:For ticket 1, revert to supported memory settings and run a controlled RAM stability test. Aggressive timings may destabilize the memory subsystem without any disk fault.
B:For ticket 2, stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing. Damaged power-regulation components can destabilize the platform and create a safety concern.
C:For ticket 1, revert to supported memory settings and run a controlled RAM stability test. Aggressive timings may destabilize the memory subsystem without any disk fault. For ticket 2, stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing. Damaged power-regulation components can destabilize the platform and create a safety concern.
Question 817
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A computer intermittently reboots after a module upgrade, and a memory diagnostic reports errors only with one new DIMM installed. A notebook freezes when moved, but remains stable on a desk; its removable RAM has not been secured after service. What is the most appropriate plan for this situation?
- Replace or isolate the failing supported DIMM after confirming its slot and configuration; Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test; Reseat the supported memory and inspect the retention clips for movement.
- Replace or isolate the failing supported DIMM after confirming its slot and configuration; stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
- Revert to supported memory settings and run a controlled RAM stability test; stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
Explanation
Correct Answer
A:For ticket (1), Repeatable memory errors tied to one module indicate a likely hardware defect. For ticket (2), Vibration-sensitive faults often indicate loose internal contacts rather than a background app.
Incorrect Answers
B:For ticket 1, replace or isolate the failing supported DIMM after confirming its slot and configuration. Repeatable memory errors tied to one module indicate a likely hardware defect.
C:For ticket 2, reseat the supported memory and inspect the retention clips for movement. Vibration-sensitive faults often indicate loose internal contacts rather than a background app.
D:For ticket 1, replace or isolate the failing supported DIMM after confirming its slot and configuration. Repeatable memory errors tied to one module indicate a likely hardware defect. For ticket 2, reseat the supported memory and inspect the retention clips for movement. Vibration-sensitive faults often indicate loose internal contacts rather than a background app.
Question 818
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: An office workstation produces spontaneous crashes and visible swollen capacitors are found on the motherboard. A notebook freezes when moved, but remains stable on a desk; its removable RAM has not been secured after service. Which course of action addresses the stated issues?
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing; replace or isolate the failing supported DIMM after confirming its slot and configuration.
- Revert to supported memory settings and run a controlled RAM stability test; replace or isolate the failing supported DIMM after confirming its slot and configuration.
- Stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing; Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test; Reseat the supported memory and inspect the retention clips for movement.
Explanation
Correct Answer
C:For ticket (1), Damaged power-regulation components can destabilize the platform and create a safety concern. For ticket (2), Vibration-sensitive faults often indicate loose internal contacts rather than a background app.
Incorrect Answers
A:For ticket 2, reseat the supported memory and inspect the retention clips for movement. Vibration-sensitive faults often indicate loose internal contacts rather than a background app.
B:For ticket 1, stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing. Damaged power-regulation components can destabilize the platform and create a safety concern. For ticket 2, reseat the supported memory and inspect the retention clips for movement. Vibration-sensitive faults often indicate loose internal contacts rather than a background app.
D:For ticket 1, stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing. Damaged power-regulation components can destabilize the platform and create a safety concern.
Question 819
A service coordinator has THREE separate support tickets and needs the correct matching actions: A desktop begins showing random system crashes only after a third-party high-frequency memory profile is enabled. A computer intermittently reboots after a module upgrade, and a memory diagnostic reports errors only with one new DIMM installed. An office workstation produces spontaneous crashes and visible swollen capacitors are found on the motherboard. Which response best addresses these needs?
- Reseat the supported memory and inspect the retention clips for movement; replace or isolate the failing supported DIMM after confirming its slot and configuration; and stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
- Revert to supported memory settings and run a controlled RAM stability test; Reseat the supported memory and inspect the retention clips for movement; and stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
- Revert to supported memory settings and run a controlled RAM stability test; replace or isolate the failing supported DIMM after confirming its slot and configuration; and Reseat the supported memory and inspect the retention clips for movement.
- Revert to supported memory settings and run a controlled RAM stability test; replace or isolate the failing supported DIMM after confirming its slot and configuration; and stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing.
Explanation
Correct Answer
D:For ticket (1), Aggressive timings may destabilize the memory subsystem without any disk fault. For ticket (2), Repeatable memory errors tied to one module indicate a likely hardware defect. For ticket (3), Damaged power-regulation components can destabilize the platform and create a safety concern.
Incorrect Answers
A:For ticket 1, revert to supported memory settings and run a controlled RAM stability test. Aggressive timings may destabilize the memory subsystem without any disk fault.
B:For ticket 2, replace or isolate the failing supported DIMM after confirming its slot and configuration. Repeatable memory errors tied to one module indicate a likely hardware defect.
C:For ticket 3, stop normal use and arrange system-board replacement or qualified repair rather than continued stress testing. Damaged power-regulation components can destabilize the platform and create a safety concern.
Question 820
A service bench observes this hardware or network symptom: A support team buys an ARM-based laptop and assumes its installed x64-only diagnostic utility runs natively without compatibility software. What should the support specialist recommend FIRST within the stated limits?
- Verify the sound card's slot, driver and required audio input specifications.
- Add a supported network interface card rather than unrelated graphics expansion.
- Check the software's supported CPU architecture and approved emulation options.
- Install a compatible video capture device with an HDMI input.
Explanation
Correct Answer
C:ARM and x86/x64 processors use different instruction architectures, affecting native binary execution.
Incorrect Answers
A:Sound expansion hardware can add supported recording and playback capabilities; aRM and x86/x64 processors use different instruction architectures, affecting native binary execution.
B:A NIC provides Ethernet networking and MAC-layer functionality; aRM and x86/x64 processors use different instruction architectures, affecting native binary execution.
D:Graphics display outputs and video-capture inputs perform different roles; aRM and x86/x64 processors use different instruction architectures, affecting native binary execution.
CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests