Pass Your CompTIA 220-1201 Exam Easy!

CompTIA 220-1201 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

220-1201 Premium Bundle

$79.99

CompTIA 220-1201 Premium Bundle

220-1201 Premium File: 527 Questions & Answers

Last Update: Oct 05, 2026

220-1201 Training Course: 106 Video Lectures

220-1201 PDF Study Guide: 2615 Pages

220-1201 Bundle gives you unlimited access to "220-1201" files. However, this does not replace the need for a .vce exam simulator. To download VCE exam simulator click here
CompTIA 220-1201 Premium Bundle
CompTIA 220-1201 Premium Bundle

220-1201 Premium File: 527 Questions & Answers

Last Update: Oct 05, 2026

220-1201 Training Course: 106 Video Lectures

220-1201 PDF Study Guide: 2615 Pages

$79.99

220-1201 Bundle gives you unlimited access to "220-1201" files. However, this does not replace the need for a .vce exam simulator. To download your .vce exam simulator click here

CompTIA 220-1201 Practice Test 38

Question 370

A field technician verifies the following customer equipment condition: A high-end desktop shuts off only when the GPU and CPU both draw peak current, with normal temperatures recorded. Which response BEST addresses the actual cause or requirement?

  1. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.
  2. Connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  3. Restore the known-good firmware settings and verify the storage controller/boot mode.
  4. Check PSU capacity and transient load behavior before replacing the CPU cooler.

Explanation

Correct Answer

D:

Power demand may exceed the supply despite acceptable component temperatures.

Incorrect Answers

A:

Replacing the supported CMOS/RTC battery and reconfigure UEFI settings as needed would not check PSU capacity and transient load behavior.

B:

Connecting the manufacturer's specified expansion-card power lead and verifying the supply budget would not check PSU capacity and transient load behavior.

C:

Restoring the known-good firmware settings and verifying the storage controller/boot mode would not check PSU capacity and transient load behavior.

Question 371

An IT support worker is asked to resolve this case: A computer loses firmware date and custom boot settings whenever it remains unplugged overnight. Which next step MOST directly resolves the reported condition?

  1. Check PSU capacity and transient load behavior before replacing the CPU cooler.
  2. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.
  3. Connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  4. Restore the known-good firmware settings and verify the storage controller/boot mode.

Explanation

Correct Answer

B:

The RTC battery maintains time and some firmware state when mains power is disconnected.

Incorrect Answers

A:

Checking PSU capacity and transient load behavior would not replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.

C:

Connecting the manufacturer's specified expansion-card power lead and verifying the supply budget would not replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.

D:

Restoring the known-good firmware settings and verifying the storage controller/boot mode would not replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.

Question 372

A service bench observes this hardware or network symptom: A workstation intermittently resets after an expansion card was installed and its auxiliary power connector remains unplugged. What should the support specialist recommend FIRST within the stated limits?

  1. Connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  2. Restore the known-good firmware settings and verify the storage controller/boot mode.
  3. Check PSU capacity and transient load behavior before replacing the CPU cooler.
  4. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.

Explanation

Correct Answer

A:

Unpowered expansion devices can fail under load and trigger unstable system operation.

Incorrect Answers

B:

Restoring the known-good firmware settings and verifying the storage controller/boot mode would not connect the manufacturer's specified expansion-card power lead and verify the supply budget.

C:

Checking PSU capacity and transient load behavior would not connect the manufacturer's specified expansion-card power lead and verify the supply budget.

D:

Replacing the supported CMOS/RTC battery and reconfigure UEFI settings as needed would not connect the manufacturer's specified expansion-card power lead and verify the supply budget.

Question 373

During a controlled office IT maintenance window, the technician notes: A technician changes several BIOS options at once and the PC stops detecting its boot disk although hardware tests pass. What is the MOST appropriate technician action?

  1. Connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  2. Restore the known-good firmware settings and verify the storage controller/boot mode.
  3. Check PSU capacity and transient load behavior before replacing the CPU cooler.
  4. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.

Explanation

Correct Answer

B:

Configuration changes can prevent an otherwise healthy installed OS from appearing bootable.

Incorrect Answers

A:

Connecting the manufacturer's specified expansion-card power lead and verifying the supply budget would not restore the known-good firmware settings and verify the storage controller/boot mode.

C:

Checking PSU capacity and transient load behavior would not restore the known-good firmware settings and verify the storage controller/boot mode.

D:

Replacing the supported CMOS/RTC battery and reconfigure UEFI settings as needed would not restore the known-good firmware settings and verify the storage controller/boot mode.

Question 374

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A high-end desktop shuts off only when the GPU and CPU both draw peak current, with normal temperatures recorded. A computer loses firmware date and custom boot settings whenever it remains unplugged overnight. Which course of action addresses the stated issues?

  1. Check PSU capacity and transient load behavior before replacing the CPU cooler; restore the known-good firmware settings and verify the storage controller/boot mode.
  2. Connect the manufacturer's specified expansion-card power lead and verify the supply budget; restore the known-good firmware settings and verify the storage controller/boot mode.
  3. Check PSU capacity and transient load behavior before replacing the CPU cooler; replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.
  4. Connect the manufacturer's specified expansion-card power lead and verify the supply budget; replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.

Explanation

Correct Answer

C:

For ticket (1), Power demand may exceed the supply despite acceptable component temperatures. For ticket (2), The RTC battery maintains time and some firmware state when mains power is disconnected.

Incorrect Answers

A:

For ticket 2, replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed. The RTC battery maintains time and some firmware state when mains power is disconnected.

B:

For ticket 1, check PSU capacity and transient load behavior before replacing the CPU cooler. Power demand may exceed the supply despite acceptable component temperatures. For ticket 2, replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed. The RTC battery maintains time and some firmware state when mains power is disconnected.

D:

For ticket 1, check PSU capacity and transient load behavior before replacing the CPU cooler. Power demand may exceed the supply despite acceptable component temperatures.

Question 375

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A high-end desktop shuts off only when the GPU and CPU both draw peak current, with normal temperatures recorded. A workstation intermittently resets after an expansion card was installed and its auxiliary power connector remains unplugged. Which response best addresses these needs?

  1. Check PSU capacity and transient load behavior before replacing the CPU cooler; connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  2. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed; connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  3. Check PSU capacity and transient load behavior before replacing the CPU cooler; restore the known-good firmware settings and verify the storage controller/boot mode.
  4. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed; restore the known-good firmware settings and verify the storage controller/boot mode.

Explanation

Correct Answer

A:

For ticket (1), Power demand may exceed the supply despite acceptable component temperatures. For ticket (2), Unpowered expansion devices can fail under load and trigger unstable system operation.

Incorrect Answers

B:

For ticket 1, check PSU capacity and transient load behavior before replacing the CPU cooler. Power demand may exceed the supply despite acceptable component temperatures.

C:

For ticket 2, connect the manufacturer's specified expansion-card power lead and verify the supply budget. Unpowered expansion devices can fail under load and trigger unstable system operation.

D:

For ticket 1, check PSU capacity and transient load behavior before replacing the CPU cooler. Power demand may exceed the supply despite acceptable component temperatures. For ticket 2, connect the manufacturer's specified expansion-card power lead and verify the supply budget. Unpowered expansion devices can fail under load and trigger unstable system operation.

Question 376

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A computer loses firmware date and custom boot settings whenever it remains unplugged overnight. A technician changes several BIOS options at once and the PC stops detecting its boot disk although hardware tests pass. What is the most appropriate plan for this situation?

  1. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed; restore the known-good firmware settings and verify the storage controller/boot mode.
  2. Check PSU capacity and transient load behavior before replacing the CPU cooler; restore the known-good firmware settings and verify the storage controller/boot mode.
  3. Replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed; connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  4. Check PSU capacity and transient load behavior before replacing the CPU cooler; connect the manufacturer's specified expansion-card power lead and verify the supply budget.

Explanation

Correct Answer

A:

For ticket (1), The RTC battery maintains time and some firmware state when mains power is disconnected. For ticket (2), Configuration changes can prevent an otherwise healthy installed OS from appearing bootable.

Incorrect Answers

B:

For ticket 1, replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed. The RTC battery maintains time and some firmware state when mains power is disconnected.

C:

For ticket 2, restore the known-good firmware settings and verify the storage controller/boot mode. Configuration changes can prevent an otherwise healthy installed OS from appearing bootable.

D:

For ticket 1, replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed. The RTC battery maintains time and some firmware state when mains power is disconnected. For ticket 2, restore the known-good firmware settings and verify the storage controller/boot mode. Configuration changes can prevent an otherwise healthy installed OS from appearing bootable.

Question 377

A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A workstation intermittently resets after an expansion card was installed and its auxiliary power connector remains unplugged. A technician changes several BIOS options at once and the PC stops detecting its boot disk although hardware tests pass. Which course of action addresses the stated issues?

  1. Connect the manufacturer's specified expansion-card power lead and verify the supply budget; replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.
  2. Check PSU capacity and transient load behavior before replacing the CPU cooler; replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed.
  3. Connect the manufacturer's specified expansion-card power lead and verify the supply budget; restore the known-good firmware settings and verify the storage controller/boot mode.
  4. Check PSU capacity and transient load behavior before replacing the CPU cooler; restore the known-good firmware settings and verify the storage controller/boot mode.

Explanation

Correct Answer

C:

For ticket (1), Unpowered expansion devices can fail under load and trigger unstable system operation. For ticket (2), Configuration changes can prevent an otherwise healthy installed OS from appearing bootable.

Incorrect Answers

A:

For ticket 2, restore the known-good firmware settings and verify the storage controller/boot mode. Configuration changes can prevent an otherwise healthy installed OS from appearing bootable.

B:

For ticket 1, connect the manufacturer's specified expansion-card power lead and verify the supply budget. Unpowered expansion devices can fail under load and trigger unstable system operation. For ticket 2, restore the known-good firmware settings and verify the storage controller/boot mode. Configuration changes can prevent an otherwise healthy installed OS from appearing bootable.

D:

For ticket 1, connect the manufacturer's specified expansion-card power lead and verify the supply budget. Unpowered expansion devices can fail under load and trigger unstable system operation.

Question 378

A service coordinator has THREE separate support tickets and needs the correct matching actions: A high-end desktop shuts off only when the GPU and CPU both draw peak current, with normal temperatures recorded. A computer loses firmware date and custom boot settings whenever it remains unplugged overnight. A workstation intermittently resets after an expansion card was installed and its auxiliary power connector remains unplugged. Which response best addresses these needs?

  1. Check PSU capacity and transient load behavior before replacing the CPU cooler; replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed; and restore the known-good firmware settings and verify the storage controller/boot mode.
  2. Check PSU capacity and transient load behavior before replacing the CPU cooler; replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed; and connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  3. Restore the known-good firmware settings and verify the storage controller/boot mode; replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed; and connect the manufacturer's specified expansion-card power lead and verify the supply budget.
  4. Check PSU capacity and transient load behavior before replacing the CPU cooler; restore the known-good firmware settings and verify the storage controller/boot mode; and connect the manufacturer's specified expansion-card power lead and verify the supply budget.

Explanation

Correct Answer

B:

For ticket (1), Power demand may exceed the supply despite acceptable component temperatures. For ticket (2), The RTC battery maintains time and some firmware state when mains power is disconnected. For ticket (3), Unpowered expansion devices can fail under load and trigger unstable system operation.

Incorrect Answers

A:

For ticket 3, connect the manufacturer's specified expansion-card power lead and verify the supply budget. Unpowered expansion devices can fail under load and trigger unstable system operation.

C:

For ticket 1, check PSU capacity and transient load behavior before replacing the CPU cooler. Power demand may exceed the supply despite acceptable component temperatures.

D:

For ticket 2, replace the supported CMOS/RTC battery and reconfigure UEFI settings as needed. The RTC battery maintains time and some firmware state when mains power is disconnected.

Question 379

An IT support worker is asked to resolve this case: A convertible laptop displays a clear image but ignores finger touches, while its external mouse works. Which next step MOST directly resolves the reported condition?

  1. Check the backlight and inverter circuitry using appropriate service methods.
  2. Confirm the actual panel/backlight design before ordering legacy inverter components.
  3. Calibrate the supported digitizer and verify its controller configuration before replacing the LCD.
  4. Diagnose the touch digitizer and its driver/connection independently of the image panel.

Explanation

Correct Answer

D:

Displaying pixels and sensing touch are separate functions on many convertible assemblies.

Incorrect Answers

A:

Failed backlighting can leave a faint LCD image that is only visible with external illumination; displaying pixels and sensing touch are separate functions on many convertible assemblies.

B:

Modern LED backlights generally use different power-driving circuits from older fluorescent displays; displaying pixels and sensing touch are separate functions on many convertible assemblies.

C:

Touch coordinate mapping can be incorrect even when the display image itself is sharp; displaying pixels and sensing touch are separate functions on many convertible assemblies.

Question 380

A service bench observes this hardware or network symptom: A CCFL-backlit legacy laptop screen becomes barely visible under a flashlight, although the computer still generates a video image. What should the support specialist recommend FIRST within the stated limits?

  1. Calibrate the supported digitizer and verify its controller configuration before replacing the LCD.
  2. Diagnose the touch digitizer and its driver/connection independently of the image panel.
  3. Check the backlight and inverter circuitry using appropriate service methods.
  4. Confirm the actual panel/backlight design before ordering legacy inverter components.

Explanation

Correct Answer

C:

Failed backlighting can leave a faint LCD image that is only visible with external illumination.

Incorrect Answers

A:

Touch coordinate mapping can be incorrect even when the display image itself is sharp; failed backlighting can leave a faint LCD image that is only visible with external illumination.

B:

Displaying pixels and sensing touch are separate functions on many convertible assemblies; failed backlighting can leave a faint LCD image that is only visible with external illumination.

D:

Modern LED backlights generally use different power-driving circuits from older fluorescent displays; failed backlighting can leave a faint LCD image that is only visible with external illumination.


CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests

Purchase Individually

220-1201 Premium File

Premium File
220-1201 Premium File
527 Q&A
$76.99$69.99

220-1201 Training Video Course

Training Course
220-1201 Training Video Course
106 Lectures
$27.49$24.99

220-1201 Study Guide

Study Guide
220-1201 Study Guide
2615 PDF Pages
$27.49$24.99

Site Search:

 

VISA, MasterCard, AmericanExpress, UnionPay

SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.