Question 150
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A laptop has 8 GB RAM, and a technician assigns 12 GB dedicated memory to a new virtual machine while other apps are running. A team wants to test untrusted configuration changes but accidentally mounts the host's production document directory with read/write access inside the guest. Which response best addresses these needs?
- Reduce guest memory allocation or increase host capacity under supported resource limits; remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test.
- Select the approved virtual network mode and confirm IP reachability and isolation; remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test.
- Reduce guest memory allocation or increase host capacity under supported resource limits; Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload.
- Select the approved virtual network mode and confirm IP reachability and isolation; Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload.
Explanation
Correct Answer
A:For ticket (1), Oversubscription without adequate physical memory can cause pressure or prevent a guest from starting. For ticket (2), Guest isolation is weakened when writable production host resources are exposed to the test VM.
Incorrect Answers
B:For ticket 1, reduce guest memory allocation or increase host capacity under supported resource limits. Oversubscription without adequate physical memory can cause pressure or prevent a guest from starting.
C:For ticket 2, remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test. Guest isolation is weakened when writable production host resources are exposed to the test VM.
D:For ticket 1, reduce guest memory allocation or increase host capacity under supported resource limits. Oversubscription without adequate physical memory can cause pressure or prevent a guest from starting. For ticket 2, remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test. Guest isolation is weakened when writable production host resources are exposed to the test VM.
Question 151
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A virtual machine can browse the internet but cannot contact a local lab server because its adapter is configured for NAT instead of the required bridged network. A user stores a virtual machine's disk on an almost-full host volume and sees guest writes begin to fail. What is the most appropriate plan for this situation?
- Select the approved virtual network mode and confirm IP reachability and isolation; remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test.
- Reduce guest memory allocation or increase host capacity under supported resource limits; remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test.
- Select the approved virtual network mode and confirm IP reachability and isolation; Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload.
- Reduce guest memory allocation or increase host capacity under supported resource limits; Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload.
Explanation
Correct Answer
C:For ticket (1), NAT, bridged and host-only virtual networks expose guests to different paths and security boundaries. For ticket (2), Virtual disk growth consumes real host bytes even when its advertised maximum is larger.
Incorrect Answers
A:For ticket 2, provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload. Virtual disk growth consumes real host bytes even when its advertised maximum is larger.
B:For ticket 1, select the approved virtual network mode and confirm IP reachability and isolation. NAT, bridged and host-only virtual networks expose guests to different paths and security boundaries. For ticket 2, provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload. Virtual disk growth consumes real host bytes even when its advertised maximum is larger.
D:For ticket 1, select the approved virtual network mode and confirm IP reachability and isolation. NAT, bridged and host-only virtual networks expose guests to different paths and security boundaries.
Question 152
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A team wants to test untrusted configuration changes but accidentally mounts the host's production document directory with read/write access inside the guest. A user stores a virtual machine's disk on an almost-full host volume and sees guest writes begin to fail. Which course of action addresses the stated issues?
- Remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test; select the approved virtual network mode and confirm IP reachability and isolation.
- Reduce guest memory allocation or increase host capacity under supported resource limits; select the approved virtual network mode and confirm IP reachability and isolation.
- Remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test; Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload.
- Reduce guest memory allocation or increase host capacity under supported resource limits; Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload.
Explanation
Correct Answer
C:For ticket (1), Guest isolation is weakened when writable production host resources are exposed to the test VM. For ticket (2), Virtual disk growth consumes real host bytes even when its advertised maximum is larger.
Incorrect Answers
A:For ticket 2, provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload. Virtual disk growth consumes real host bytes even when its advertised maximum is larger.
B:For ticket 1, remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test. Guest isolation is weakened when writable production host resources are exposed to the test VM. For ticket 2, provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload. Virtual disk growth consumes real host bytes even when its advertised maximum is larger.
D:For ticket 1, remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test. Guest isolation is weakened when writable production host resources are exposed to the test VM.
Question 153
A service coordinator has THREE separate support tickets and needs the correct matching actions: A laptop has 8 GB RAM, and a technician assigns 12 GB dedicated memory to a new virtual machine while other apps are running. A virtual machine can browse the internet but cannot contact a local lab server because its adapter is configured for NAT instead of the required bridged network. A team wants to test untrusted configuration changes but accidentally mounts the host's production document directory with read/write access inside the guest. Which response best addresses these needs?
- Reduce guest memory allocation or increase host capacity under supported resource limits; Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload; and remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test.
- Reduce guest memory allocation or increase host capacity under supported resource limits; select the approved virtual network mode and confirm IP reachability and isolation; and Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload.
- Reduce guest memory allocation or increase host capacity under supported resource limits; select the approved virtual network mode and confirm IP reachability and isolation; and remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test.
- Provide adequate host storage capacity and confirm guest disk provisioning before restarting the workload; select the approved virtual network mode and confirm IP reachability and isolation; and remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test.
Explanation
Correct Answer
C:For ticket (1), Oversubscription without adequate physical memory can cause pressure or prevent a guest from starting. For ticket (2), NAT, bridged and host-only virtual networks expose guests to different paths and security boundaries. For ticket (3), Guest isolation is weakened when writable production host resources are exposed to the test VM.
Incorrect Answers
A:For ticket 2, select the approved virtual network mode and confirm IP reachability and isolation. NAT, bridged and host-only virtual networks expose guests to different paths and security boundaries.
B:For ticket 3, remove unnecessary shared-folder access and take a clean VM snapshot before the controlled test. Guest isolation is weakened when writable production host resources are exposed to the test VM.
D:For ticket 1, reduce guest memory allocation or increase host capacity under supported resource limits. Oversubscription without adequate physical memory can cause pressure or prevent a guest from starting.
Question 154
A field technician verifies the following customer equipment condition: A desktop shows no LEDs or fan movement when its power button is pressed, and the outlet was recently moved. Which response BEST addresses the actual cause or requirement?
- Verify wall power, power cord, PSU switch and standby output before replacing internal components.
- Check port-specific Power Delivery support rather than diagnosing a failed battery.
- Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
- Test with a known-good properly rated power source before removing the PSU.
Explanation
Correct Answer
A:A dead AC path can mimic system-board failure and should be checked safely first.
Incorrect Answers
B:Checking port-specific Power Delivery support rather than diagnosing a failed battery would not verify wall power, power cord, PSU switch and standby output.
C:Disconnect the suspect accessory and inspect its cable/port for a short would not verify wall power, power cord, PSU switch and standby output.
D:Testing with a known-good properly rated power source would not verify wall power, power cord, PSU switch and standby output.
Question 155
An IT support worker is asked to resolve this case: A laptop charges through one USB-C port but not through a second data-only USB-C port with the same adapter. Which next step MOST directly resolves the reported condition?
- Test with a known-good properly rated power source before removing the PSU.
- Verify wall power, power cord, PSU switch and standby output before replacing internal components.
- Check port-specific Power Delivery support rather than diagnosing a failed battery.
- Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
Explanation
Correct Answer
C:Data-capable USB-C ports do not necessarily accept system charging power.
Incorrect Answers
A:Testing with a known-good properly rated power source would not check port-specific Power Delivery support rather than diagnosing a failed battery.
B:Verifying wall power, power cord, PSU switch and standby output would not check port-specific Power Delivery support rather than diagnosing a failed battery.
D:Disconnect the suspect accessory and inspect its cable/port for a short would not check port-specific Power Delivery support rather than diagnosing a failed battery.
Question 156
A service bench observes this hardware or network symptom: A computer powers on briefly then shuts off when the user plugs in a damaged external USB accessory. What should the support specialist recommend FIRST within the stated limits?
- Verify wall power, power cord, PSU switch and standby output before replacing internal components.
- Check port-specific Power Delivery support rather than diagnosing a failed battery.
- Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
- Test with a known-good properly rated power source before removing the PSU.
Explanation
Correct Answer
C:A fault on a peripheral power rail can activate protection and drop host power.
Incorrect Answers
A:A dead AC path can mimic system-board failure and should be checked safely first; a fault on a peripheral power rail can activate protection and drop host power.
B:Data-capable USB-C ports do not necessarily accept system charging power; a fault on a peripheral power rail can activate protection and drop host power.
D:Faulty upstream power distribution can prevent a healthy computer from starting; a fault on a peripheral power rail can activate protection and drop host power.
Question 157
During a controlled office IT maintenance window, the technician notes: A workstation's power strip indicator is dark after a storm, while the PC supply and internal wiring appear undamaged. What is the MOST appropriate technician action?
- Test with a known-good properly rated power source before removing the PSU.
- Verify wall power, power cord, PSU switch and standby output before replacing internal components.
- Check port-specific Power Delivery support rather than diagnosing a failed battery.
- Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
Explanation
Correct Answer
A:Faulty upstream power distribution can prevent a healthy computer from starting.
Incorrect Answers
B:Verifying wall power, power cord, PSU switch and standby output would not test with a known-good properly rated power source.
C:Checking port-specific Power Delivery support rather than diagnosing a failed battery would not test with a known-good properly rated power source.
D:Disconnect the suspect accessory and inspect its cable/port for a short would not test with a known-good properly rated power source.
Question 158
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A desktop shows no LEDs or fan movement when its power button is pressed, and the outlet was recently moved. A laptop charges through one USB-C port but not through a second data-only USB-C port with the same adapter. Which course of action addresses the stated issues?
- Verify wall power, power cord, PSU switch and standby output before replacing internal components; test with a known-good properly rated power source before removing the PSU.
- Disconnect the suspect accessory and inspect its cable/port for a short before retesting; test with a known-good properly rated power source before removing the PSU.
- Verify wall power, power cord, PSU switch and standby output before replacing internal components; check port-specific Power Delivery support rather than diagnosing a failed battery.
- Disconnect the suspect accessory and inspect its cable/port for a short before retesting; check port-specific Power Delivery support rather than diagnosing a failed battery.
Explanation
Correct Answer
C:For ticket (1), A dead AC path can mimic system-board failure and should be checked safely first. For ticket (2), Data-capable USB-C ports do not necessarily accept system charging power.
Incorrect Answers
A:For ticket 2, check port-specific Power Delivery support rather than diagnosing a failed battery. Data-capable USB-C ports do not necessarily accept system charging power.
B:For ticket 1, verify wall power, power cord, PSU switch and standby output before replacing internal components. A dead AC path can mimic system-board failure and should be checked safely first. For ticket 2, check port-specific Power Delivery support rather than diagnosing a failed battery. Data-capable USB-C ports do not necessarily accept system charging power.
D:For ticket 1, verify wall power, power cord, PSU switch and standby output before replacing internal components. A dead AC path can mimic system-board failure and should be checked safely first.
Question 159
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A desktop shows no LEDs or fan movement when its power button is pressed, and the outlet was recently moved. A computer powers on briefly then shuts off when the user plugs in a damaged external USB accessory. Which response best addresses these needs?
- Check port-specific Power Delivery support rather than diagnosing a failed battery; Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
- Verify wall power, power cord, PSU switch and standby output before replacing internal components; test with a known-good properly rated power source before removing the PSU.
- Check port-specific Power Delivery support rather than diagnosing a failed battery; test with a known-good properly rated power source before removing the PSU.
- Verify wall power, power cord, PSU switch and standby output before replacing internal components; Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
Explanation
Correct Answer
D:For ticket (1), A dead AC path can mimic system-board failure and should be checked safely first. For ticket (2), A fault on a peripheral power rail can activate protection and drop host power.
Incorrect Answers
A:For ticket 1, verify wall power, power cord, PSU switch and standby output before replacing internal components. A dead AC path can mimic system-board failure and should be checked safely first.
B:For ticket 2, disconnect the suspect accessory and inspect its cable/port for a short before retesting. A fault on a peripheral power rail can activate protection and drop host power.
C:For ticket 1, verify wall power, power cord, PSU switch and standby output before replacing internal components. A dead AC path can mimic system-board failure and should be checked safely first. For ticket 2, disconnect the suspect accessory and inspect its cable/port for a short before retesting. A fault on a peripheral power rail can activate protection and drop host power.
Question 160
A support team must resolve TWO distinct issues at the same location, using approved non-destructive maintenance: A laptop charges through one USB-C port but not through a second data-only USB-C port with the same adapter. A workstation's power strip indicator is dark after a storm, while the PC supply and internal wiring appear undamaged. What is the most appropriate plan for this situation?
- Verify wall power, power cord, PSU switch and standby output before replacing internal components; test with a known-good properly rated power source before removing the PSU.
- Check port-specific Power Delivery support rather than diagnosing a failed battery; Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
- Verify wall power, power cord, PSU switch and standby output before replacing internal components; Disconnect the suspect accessory and inspect its cable/port for a short before retesting.
- Check port-specific Power Delivery support rather than diagnosing a failed battery; test with a known-good properly rated power source before removing the PSU.
Explanation
Correct Answer
D:For ticket (1), Data-capable USB-C ports do not necessarily accept system charging power. For ticket (2), Faulty upstream power distribution can prevent a healthy computer from starting.
Incorrect Answers
A:For ticket 1, check port-specific Power Delivery support rather than diagnosing a failed battery. Data-capable USB-C ports do not necessarily accept system charging power.
B:For ticket 2, test with a known-good properly rated power source before removing the PSU. Faulty upstream power distribution can prevent a healthy computer from starting.
C:For ticket 1, check port-specific Power Delivery support rather than diagnosing a failed battery. Data-capable USB-C ports do not necessarily accept system charging power. For ticket 2, test with a known-good properly rated power source before removing the PSU. Faulty upstream power distribution can prevent a healthy computer from starting.
CompTIA A+ Certification Exam: Core 1 (220-1201) Practice Tests