• Home
  • EMC
  • E20-390 VNX Solutions Specialist for Implementation Engineers Dumps

Pass Your EMC E20-390 Exam Easy!

100% Real EMC E20-390 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

EMC E20-390 Practice Test Questions in VCE Format

File Votes Size Date
File
EMC.Realtests.E20-390.v2015-04-08.by.Sophia.411q.vce
Votes
19
Size
2.36 MB
Date
Apr 08, 2015
File
EMC.ActualTests.E20-390.v2013-08-21.by.TechExpert.334q.vce
Votes
6
Size
314.98 KB
Date
Aug 21, 2013
File
EMC.ActualTests.E20-390.v2012-07-23.by.Anonymous.213q.vce
Votes
2
Size
106.2 KB
Date
Jul 23, 2012
File
EMC.Braindump.E20-390.v2012-02-16.by.VPOUO.162q.vce
Votes
2
Size
3.96 MB
Date
Feb 16, 2012

EMC E20-390 Practice Test Questions, Exam Dumps

EMC E20-390 (VNX Solutions Specialist for Implementation Engineers) exam dumps vce, practice test questions, study guide & video training course to study and pass quickly and easily. EMC E20-390 VNX Solutions Specialist for Implementation Engineers exam dumps & practice test questions and answers. You need avanset vce exam simulator in order to study the EMC E20-390 certification exam dumps & EMC E20-390 practice test questions in vce format.

Mastering the Foundations for the E20-390 Exam: Isilon Architecture and Initial Setup

The E20-390 Exam, officially titled the Isilon Solutions Specialist Exam for Implementation Engineers, represents a crucial benchmark for IT professionals seeking to validate their skills in deploying and managing Dell EMC Isilon scale-out Network Attached Storage (NAS) solutions. Passing this exam earns the candidate the Dell EMC Certified Specialist - Implementation Engineer, Isilon Solutions certification, a credential recognized across the industry. This certification signifies a deep understanding of Isilon architecture, installation procedures, configuration, and fundamental management tasks. It is specifically designed for individuals in roles such as implementation engineers, system administrators, and storage professionals who are responsible for the hands-on aspects of Isilon cluster deployment.

The value of this certification is rooted in the growing demand for robust, scalable storage solutions capable of handling the massive data volumes generated by modern enterprises. As organizations grapple with big data, analytics, high-performance computing, and large-scale file-based workflows, Isilon has become a prominent platform. The E20-390 Exam covers the critical knowledge areas required to successfully implement these solutions. The exam curriculum is structured around several key domains, including Isilon hardware and software architecture, initial cluster installation and configuration, network design, data protection strategies, and basic cluster administration. This initial part of our series will lay the groundwork, exploring these foundational concepts in detail.

The Evolution of Network Attached Storage (NAS)

To appreciate the significance of Isilon and the E20-390 Exam, it is important to understand the evolution of NAS technology. Initially, NAS systems were developed to provide simple, centralized file storage over a network, offering a convenient alternative to direct-attached storage. These traditional NAS systems typically followed a "scale-up" architecture. In a scale-up model, increasing capacity or performance meant adding more disks to an existing controller or, eventually, replacing the entire system with a more powerful one. This approach, while effective for a time, presented significant limitations as data growth accelerated exponentially.

The primary drawbacks of scale-up NAS include performance bottlenecks, disruptive data migrations, and increasing management complexity. As more disks were added, the central controllers would become a chokepoint, limiting throughput and increasing latency. When a system reached its maximum capacity, administrators faced a costly and risky "forklift upgrade," requiring a complete data migration to a new, larger system. The E20-390 Exam content is built upon the solution to these challenges: the "scale-out" architecture. Scale-out NAS, pioneered by platforms like Isilon, allows organizations to expand capacity and performance linearly and non-disruptively by simply adding more nodes to a cluster.

Core Concepts of the Isilon Scale-Out Architecture

The Isilon scale-out architecture is the central theme of the E20-390 Exam. Its fundamental building block is the Isilon node, a self-contained server that includes CPU, memory, networking, and storage drives. These nodes are intelligently clustered together using a high-speed, low-latency backend network, traditionally InfiniBand. This interconnect is crucial as it facilitates constant communication and data sharing between all the nodes in the cluster, ensuring that the system operates as a single, cohesive entity. Unlike traditional NAS, where a pair of controllers manages all the storage, the Isilon architecture is fully distributed, with no single point of failure or performance bottleneck.

The magic that unifies these individual hardware nodes is the OneFS operating system. OneFS creates a single, global namespace and a single file system that spans across every node in the cluster. From the perspective of a user or an application, the entire Isilon cluster appears as one massive, easily accessible storage volume. This design dramatically simplifies administration. Instead of managing dozens of separate volumes and LUNs, administrators manage a single pool of storage. As the business needs grow, new nodes can be added to the cluster in as little as sixty seconds, with their resources automatically integrated into the existing file system, seamlessly increasing both capacity and performance.

OneFS Operating System: The Brains of the Operation

The OneFS operating system is a sophisticated piece of software and a primary focus for anyone preparing for the E20-390 Exam. It is a fully symmetric, distributed file system, meaning that every node in the cluster is a peer and can perform I/O operations for any client. There is no master or primary node, which enhances both resiliency and performance. When a client writes a file to the Isilon cluster, OneFS intelligently breaks the file into smaller units, or "stripes," and distributes these stripes, along with parity information for data protection, across multiple nodes. This ensures that the workload is balanced and that the failure of a single node or drive does not lead to data loss.

OneFS is responsible for managing all aspects of the cluster's operation. It handles client connectivity, authentication, and access control. It also manages the cluster's robust data protection through a software-based feature called FlexProtect, which uses Reed-Solomon erasure coding. This is a significant departure from traditional systems that rely on hardware RAID controllers. Furthermore, OneFS integrates powerful data management features directly into the operating system. These include efficient snapshot capabilities for point-in-time recovery (SnapshotIQ), asynchronous replication for disaster recovery (SyncIQ), and automated storage tiering (SmartPools), all of which are essential topics for the E20-390 Exam.

Demystifying Isilon Hardware Components

A thorough understanding of Isilon hardware is a prerequisite for passing the E20-390 Exam. Isilon clusters are built from various types of nodes, each designed for specific workload requirements. For example, the F-series nodes are all-flash platforms designed for extreme performance workloads. The H-series nodes offer a hybrid balance of performance and capacity, typically using a mix of SSDs for caching and HDDs for data storage. The A-series nodes are built for high-density, low-cost archival storage. An implementation engineer must be able to identify these different node types and understand their appropriate use cases.

Inside each node, you will find standard server components: multiple CPUs, significant amounts of RAM which is heavily used for caching, and a variety of network interfaces. These interfaces are divided into two categories: frontend and backend. Frontend interfaces, typically Ethernet, are used for client connections, providing access to the file system data. Backend interfaces, which are often high-throughput, low-latency InfiniBand or Ethernet, are dedicated to the private, internal network that allows the nodes to communicate with each other. This separation is critical for maintaining high performance and is a key design principle tested in the E20-390 Exam.

Initial Cluster Installation and Configuration

The practical, hands-on process of bringing a new Isilon cluster online is a major domain of the E20-390 Exam. The process begins with meticulous planning long before the hardware arrives. This planning phase includes designing the network layout, allocating IP address ranges, and defining the cluster's naming conventions. Once the hardware is on-site, the first step is the physical installation, which involves racking the nodes, connecting power supplies, and cabling the frontend and backend networks correctly. Proper cabling of the InfiniBand backend network is especially critical for cluster health and performance.

After the physical setup is complete, the software configuration begins. The initial configuration of a new cluster is typically done through a serial console connection to one of the nodes. The system runs an automated configuration wizard that guides the engineer through the essential setup parameters. These include creating a cluster name, setting the OneFS version, defining the internal IP address range for the backend network, and configuring the external network settings for client access. The wizard also prompts for setting the root user password and joining the initial nodes together to form the cluster. Accuracy during this stage is vital for a stable deployment.

Network Configuration for an Isilon Cluster

Networking is a complex and vital aspect of any Isilon deployment, and the E20-390 Exam dedicates significant attention to it. A well-designed network ensures high performance, high availability, and ease of management. Isilon networking is built around the concept of SmartConnect, a powerful software module that provides intelligent client connection load balancing and dynamic failover. SmartConnect works by assigning a single, fully qualified domain name (FQDN) to a pool of IP addresses that are distributed across the nodes in the cluster. When a client requests a connection using this name, SmartConnect intelligently directs the client to the least busy node, based on policies like round-robin, connection count, or CPU utilization.

Proper network segmentation is another key principle. The frontend client network must be logically and often physically separated from the private backend network used for inter-node communication. This prevents client traffic from interfering with the latency-sensitive operations of the OneFS distributed file system. Implementation engineers must also be proficient in configuring advanced networking features. This includes setting up link aggregation (LACP) to bundle multiple network ports into a single logical link for increased bandwidth and redundancy. Understanding how to configure VLANs to segregate different types of client traffic is also a critical skill for managing a secure and efficient Isilon environment.

Understanding Data Layout and Protection with FlexProtect

How OneFS protects data is fundamentally different from traditional RAID systems and is a core concept tested in the E20-390 Exam. Instead of grouping disks into RAID sets, Isilon uses a software-defined approach called FlexProtect. When a file is written to the cluster, OneFS breaks it into smaller chunks and writes these chunks, along with mathematically calculated protection blocks (erasure codes), across multiple nodes and drives. This method ensures that data is protected at the file level, allowing for much greater flexibility and efficiency than hardware-based RAID.

FlexProtect provides various levels of protection that an administrator can set, such as N+1, N+2, N+3, or N+4, which allow the cluster to withstand the simultaneous failure of one, two, three, or four nodes or drives, respectively, without any data loss. For example, an N+2:1 protection level means the cluster can tolerate two drive failures or one node failure. This is achieved using Reed-Solomon erasure coding, a method of adding parity data that is more space-efficient than simple mirroring. A major advantage of this approach is the speed of rebuilds. When a drive fails, OneFS only needs to recalculate the missing data blocks, a process that is distributed across all nodes in the cluster, making it significantly faster than traditional RAID rebuilds.

Preparing for the E20-390 Exam: Study Strategies

Successfully preparing for the E20-390 Exam requires a combination of theoretical knowledge and practical understanding. The most important resource is the official Dell EMC training material, including the student guides and instructor-led courses specifically designed for this certification. These materials are tailored to the exam objectives and provide the most accurate and in-depth information. It is also highly recommended to thoroughly review the official product documentation, white papers, and best practice guides for Isilon. These documents offer real-world context and detail that goes beyond the training courses.

Beyond book knowledge, hands-on experience is invaluable. If possible, get access to a physical Isilon cluster or a lab environment to practice the tasks covered in the exam. This includes running through the initial configuration wizard, setting up network pools, creating file shares, and observing how the cluster behaves under different conditions. If a physical lab is not available, Isilon offers a free, downloadable virtual node simulator (OneFS Simulator) that can be run on a hypervisor. This simulator provides a fully functional OneFS environment, allowing you to practice with the command-line interface (CLI) and the WebUI, which is essential for building confidence and reinforcing your learning.

The Journey Ahead: What to Expect in This Series

This first part of our five-part series has laid the foundational groundwork necessary for approaching the E20-390 Exam. We have explored the evolution from scale-up to scale-out NAS, delved into the core architectural components of Isilon hardware and the OneFS operating system, and covered the essential first steps of installation and network configuration. We also touched upon the unique way Isilon protects data with FlexProtect. These concepts are the bedrock upon which all other Isilon knowledge is built. Understanding them thoroughly is the first and most critical step towards achieving certification.

In the subsequent parts of this series, we will build upon this foundation to explore more advanced topics. Part 2 will focus on the day-to-day administration of an Isilon cluster, including managing access protocols like SMB and NFS, using the web administration and command-line interfaces, and monitoring cluster health. We will then move on to advanced data services, security concepts, and performance tuning. The goal of this series is to provide a comprehensive guide that not only helps you prepare for the E20-390 Exam but also equips you with the practical knowledge to become a proficient Isilon implementation specialist.

Navigating Isilon Management Interfaces

A key competency for the E20-390 Exam is proficiency in using the available Isilon management interfaces. Implementation engineers must be comfortable with both the graphical and command-line tools to effectively configure, manage, and troubleshoot the cluster. The primary graphical interface is the OneFS web administration interface, often referred to as the WebUI. This browser-based tool provides a comprehensive and intuitive dashboard for monitoring cluster health, performance, and capacity. It offers wizards and graphical representations for nearly all administrative tasks, including configuring network settings, managing file system access, and setting up data protection policies. It is the preferred tool for many day-to-day management activities.

For more advanced tasks, automation, and deep troubleshooting, the command-line interface (CLI) is indispensable. The CLI is accessible via a secure shell (SSH) connection to any node in the cluster. It provides access to a powerful set of commands, prefixed with isi, that allow for granular control over every aspect of the OneFS operating system. The E20-390 Exam will test your knowledge of common isi commands for tasks such as checking cluster status (isi status), managing volumes (isi volume), and configuring network pools (isi network pools). Proficiency in navigating the CLI is a hallmark of an experienced Isilon administrator.

Configuring Client Access with Access Zones

Isilon clusters are often used in multi-tenant environments where different departments, projects, or clients require secure, isolated access to their data. OneFS addresses this requirement through a powerful feature called Access Zones. An Access Zone is a virtual container that creates a separate access and authentication environment within a single Isilon cluster. Each zone can have its own set of authentication providers (like Active Directory or LDAP), its own base directory for user home directories, and its own SmartConnect IP pool. This allows an administrator to logically partition the cluster for different user groups, ensuring that users in one zone cannot see or access data belonging to another.

The concept of Access Zones is a critical topic for the E20-390 Exam. You will be expected to understand how to create and configure them. For instance, you might create a "Sales" zone and an "Engineering" zone. The Sales zone would be configured to authenticate against the company's primary Active Directory, while the Engineering zone might use a separate LDAP server. By assigning different base directories, you ensure that when a sales user logs in, they land in /ifs/data/sales, whereas an engineering user lands in /ifs/data/engineering. This powerful feature provides the security and isolation of multiple NAS devices within a single, unified cluster.

Mastering File Sharing for Windows Clients (SMB)

Serving files to Windows clients using the Server Message Block (SMB) protocol is one of the most common use cases for an Isilon cluster. The E20-390 Exam requires a detailed understanding of how to configure and manage SMB shares. The process begins by ensuring the cluster is properly joined to an Active Directory domain. This allows OneFS to leverage AD for authentication and access control, enabling users to access files using their standard corporate credentials. Once joined to the domain, an administrator can create SMB shares on any directory within the OneFS file system.

When creating an SMB share, several configuration options are available. The administrator must define the share name, path, and an optional description. More importantly, they must configure share-level permissions. These permissions determine which users or groups can access the share and what level of access they have (e.g., read-only, read-write, full control). It is crucial to understand that Isilon employs a multi-layered permission model. Access to a file via SMB is determined by the most restrictive combination of both the share-level permissions and the underlying file-level NTFS-style permissions on the file or directory itself. Managing these two permission layers effectively is a key skill for any Isilon implementer.

Mastering File Sharing for Linux and Unix Clients (NFS)

In addition to serving Windows clients, Isilon provides robust support for Linux and Unix clients via the Network File System (NFS) protocol. For the E20-390 Exam, you must be proficient in configuring NFS exports, which are the NFS equivalent of SMB shares. The process involves defining a directory path within the /ifs structure that you want to make available to NFS clients. Once the path is chosen, you must create an NFS export rule. This rule specifies which clients are allowed to access the export, typically defined by IP address, subnet, or netgroup.

The NFS export settings also control various access behaviors. You can specify whether the export should be read-only or read-write for clients. You can also configure user mapping. For instance, by default, the root user on an NFS client is "squashed" to the anonymous "nobody" user for security reasons, preventing a client-side root user from having unrestricted root access on the Isilon cluster. Understanding how to modify this behavior, for example, by mapping the root user to a specific user on the cluster, is an important concept. An administrator must be able to create and manage multiple NFS exports to serve different datasets to various groups of Linux/Unix servers.

Understanding Permissions and Identity Management

Effective identity and permission management is at the heart of securing data on an Isilon cluster, making it a major topic for the E20-390 Exam. OneFS has a unified permission model that is designed to handle multi-protocol environments where the same files might be accessed by both SMB and NFS clients. This can be complex because Windows (using NTFS ACLs) and Unix (using POSIX mode bits) have fundamentally different ways of representing permissions. OneFS solves this by maintaining a single, authoritative set of permissions for every file and directory and presenting a synthetic, protocol-appropriate view to the connecting client.

An implementation engineer must understand how OneFS handles user identity mapping. The System for Cross-domain Identity Management (SCIM) is the service within OneFS responsible for mapping a Windows Security Identifier (SID) to a Unix User Identifier (UID) and Group Identifier (GID), and vice-versa. This allows a user to have a consistent identity and set of permissions regardless of which protocol they use to access the data. Understanding how to configure authentication providers, manage user mapping rules, and troubleshoot permission issues in a mixed-protocol environment is a critical skill set for the exam and for real-world administration.

Leveraging Snapshots with SnapshotIQ

Data protection is more than just guarding against hardware failure; it also involves protecting against logical corruption, accidental deletions, and malware attacks. Isilon's SnapshotIQ feature provides a powerful and efficient mechanism for creating point-in-time copies of data. A snapshot is an instantaneous, read-only image of a directory or the entire file system. Because of OneFS's copy-on-write architecture, creating a snapshot is extremely fast and initially consumes very little additional disk space. Space is only consumed as the active data begins to change, and OneFS preserves the original data blocks for the snapshot.

The E20-390 Exam requires candidates to know how to create, manage, and schedule snapshots. Administrators can create snapshots manually at any time or, more commonly, set up a schedule to take them automatically at regular intervals (e.g., hourly, daily, weekly). These snapshots can then be used for rapid recovery. If a user accidentally deletes a file, an administrator can quickly access the most recent snapshot and restore the file to its previous state. On Windows clients, snapshots can be exposed via the "Previous Versions" feature, allowing end-users to perform their own file restores without needing to contact the IT department, which significantly reduces administrative overhead.

Monitoring Cluster Health and Performance

Proactive monitoring is essential for maintaining a healthy and high-performing Isilon cluster. A significant portion of the E20-390 Exam will cover the tools and techniques used to monitor the system. The WebUI provides a central dashboard that gives an at-a-glance view of key metrics. This includes capacity utilization, showing how much space is used and how much is free. It also displays real-time performance statistics, such as CPU usage, network throughput (IOPS), and client connection counts. The dashboard will also display any active events or alerts, which are critical for identifying potential issues like a failed drive or a network connectivity problem.

For more detailed analysis, OneFS provides InsightIQ, a powerful monitoring and reporting tool. InsightIQ collects vast amounts of performance data from the cluster and presents it in detailed graphical reports. It can break down performance by client, by protocol, by file, or by node, allowing administrators to pinpoint performance bottlenecks or identify misbehaving applications. From the CLI, commands like isi statistics provide raw, real-time performance data. An implementation engineer must know what key metrics to watch, how to interpret the data from these tools, and what actions to take based on the information presented.

Managing the OneFS File System

While OneFS presents a single file system, administrators have a range of tools to manage how data is stored and organized within it. The E20-390 Exam will test your knowledge of these file system management tasks. This includes understanding the directory structure, which always starts at /ifs. Administrators need to know how to create directories and set appropriate permissions. A key feature is SmartQuotas, which allows for the enforcement of storage limits. Quotas can be applied to directories, users, or groups to control capacity consumption. They can be configured as hard limits, which prevent further writes, or soft limits, which trigger notifications when a threshold is exceeded.

Another important management feature is file system analytics. The File System Analytics (FSA) job scans the cluster and generates detailed reports about the data. These reports can show data age, file types, file sizes, and owner distribution. This information is invaluable for capacity planning, identifying old or unused data that could be archived, and understanding storage growth trends. Managing the OneFS file system effectively involves using these tools to maintain an organized, secure, and efficient storage environment that meets the needs of the business while controlling costs and complexity.

Introduction to Data Replication with SyncIQ

While snapshots protect against local data loss, a comprehensive disaster recovery (DR) strategy requires having a copy of your data at a secondary location. Isilon's native replication solution is called SyncIQ, and an introduction to its concepts is relevant for the E20-390 Exam. SyncIQ provides asynchronous data replication between two Isilon clusters, typically a primary production cluster and a secondary DR cluster. It works by taking a snapshot of the source data and then efficiently transferring only the changed blocks to the target cluster. This process is highly efficient and minimizes the impact on network bandwidth and cluster performance.

Administrators configure SyncIQ policies to define what data to replicate (which directories), where to replicate it (the target cluster), and how often the replication should occur (the schedule). A policy can be set to run manually or on a recurring schedule, such as every 15 minutes or once per day, depending on the Recovery Point Objective (RPO) requirements. SyncIQ also includes features for failover and failback. In the event of a disaster at the primary site, administrators can perform a controlled failover, making the data on the DR cluster writable and redirecting users and applications to that site, ensuring business continuity.

Preparing for Advanced Isilon Concepts

This second part has focused on the essential, day-to-day administrative tasks that an Isilon implementation engineer must master. We covered navigating the management interfaces, providing multi-protocol data access through SMB and NFS, managing permissions, and utilizing core data services like SnapshotIQ and SyncIQ. Proficiency in these areas is absolutely critical for passing the E20-390 Exam. These skills form the bridge between the initial deployment and the long-term, successful operation of the Isilon cluster. They are the practical application of the architectural knowledge we discussed in the first part.

In the next part of our series, we will elevate our discussion to more advanced data management and security features within the Isilon ecosystem. We will explore powerful tools like SmartPools for automated storage tiering, which optimizes storage costs and performance. We will also delve into security topics such as role-based access control (RBAC) for administrators, antivirus integration, and data encryption. These advanced features are what allow Isilon to meet the stringent demands of enterprise environments, and a solid understanding of them is necessary to demonstrate true expertise and to confidently tackle the more challenging questions on the E20-390 Exam.

Automated Storage Tiering with SmartPools

As Isilon clusters grow, they often contain a mix of different node types, from high-performance all-flash nodes to cost-effective, high-capacity archive nodes. Managing data placement across these different tiers of storage manually would be a daunting task. This is where SmartPools, a key feature tested on the E20-390 Exam, becomes essential. SmartPools is the intelligent, policy-based software module within OneFS that automates the movement of data between different tiers of storage within the same cluster. This allows organizations to align the value of their data with the cost of the storage it resides on, optimizing both performance and total cost of ownership.

An administrator configures file pool policies that define rules for data placement. For example, a policy could be created to state that all new files with a .mkv extension are to be written directly to a high-capacity archive tier. Another policy might state that any file that has not been accessed in the last 90 days should be automatically moved from the expensive flash tier to a more economical hybrid tier. These policies are executed by a scheduled job that scans the file system and moves data non-disruptively in the background. Understanding how to create and manage these policies is a critical skill for an Isilon implementation engineer.

Optimizing Performance and Capacity with CloudPools

Beyond tiering within the cluster, modern data strategies often involve leveraging the public cloud for long-term retention and archival. Isilon addresses this with CloudPools, an advanced feature that extends the concept of automated tiering to the cloud. The E20-390 Exam expects candidates to understand the purpose and basic configuration of CloudPools. This software allows you to seamlessly tier inactive or "cold" data from your on-premises Isilon cluster to a variety of cloud storage providers, including Amazon S3, Microsoft Azure Blob, and Google Cloud Storage, as well as to other on-premises object storage systems.

When a file is tiered to the cloud, the file itself is moved to the cloud object store, but a small, intelligent stub file remains on the Isilon cluster. From a user's or application's perspective, the file still appears to be in its original location. When the file is accessed, OneFS transparently retrieves the data from the cloud and rehydrates it on the Isilon cluster. This process allows organizations to free up valuable space on their high-performance on-premises storage while retaining easy access to an almost limitless archive tier in the cloud. It is a powerful tool for managing data lifecycle and controlling storage costs.

Securing Administrative Access with Role-Based Access Control (RBAC)

In an enterprise environment, it is rarely appropriate for every administrator to have full, unrestricted root access to the storage system. The principle of least privilege dictates that users should only have the permissions necessary to perform their job functions. OneFS implements this principle through Role-Based Access Control (RBAC), a crucial security topic for the E20-390 Exam. RBAC allows the cluster's primary administrator to create specific administrative roles and then assign those roles to different users or groups. Each role is defined by a set of privileges, which grant the ability to perform specific actions or view specific information.

For example, you could create a "Helpdesk" role that has the privilege to view cluster status and manage SMB shares, but not the privilege to change network settings or modify data protection policies. You could then create a "Backup Admin" role that has privileges to manage snapshots and replication jobs, but nothing else. This granular control significantly enhances security by limiting the potential damage from accidental misconfigurations or compromised accounts. Understanding how to define roles, assign privileges, and audit administrative actions is a key aspect of securing an Isilon cluster.

Hardening the Cluster: Security Configuration and Auditing

Beyond RBAC, the E20-390 Exam requires knowledge of various other security-hardening features within OneFS. A fundamental aspect of this is configuring the cluster to comply with security best practices and corporate policies. This includes tasks such as disabling legacy, less-secure protocols like SMBv1 and older versions of NFS. It also involves configuring secure administrative access, for example, by disabling password-based SSH authentication in favor of public key authentication. OneFS also supports integration with remote syslog servers, which allows all system and audit logs to be sent to a centralized, secure logging platform for monitoring and analysis.

A particularly important security feature is auditing. OneFS can be configured to generate detailed audit logs of all protocol access events (e.g., who read, wrote, or deleted a specific file and when). This capability is often a requirement for compliance with regulations like HIPAA, SOX, or GDPR. The audit logs provide a complete, tamper-resistant record of data access that can be used for forensic analysis and to prove compliance. An implementation engineer must know how to enable and configure protocol auditing, specify which events to log, and ensure the audit data is securely stored.

Protecting Against Malware with Antivirus Integration

File-based storage systems like Isilon are a prime target for malware, such as viruses and ransomware. To combat this threat, OneFS integrates with third-party antivirus (AV) solutions through the industry-standard Internet Content Adaptation Protocol (ICAP). Understanding this integration is a key objective for the E20-390 Exam. The Isilon cluster itself does not perform the virus scanning. Instead, it acts as an ICAP client, forwarding files to one or more external ICAP AV servers for scanning. This offloads the resource-intensive scanning process from the storage cluster, preserving its performance for its primary task of serving files.

The administrator configures OneFS with the addresses of the ICAP servers and sets policies for when scanning should occur. Scanning can be configured to happen "on-access," meaning a file is scanned whenever a user attempts to open or write to it. Alternatively, scanning can be done via a scheduled "on-demand" policy that scans the file system in the background. If a threat is detected by the AV server, it informs the Isilon cluster, which can then be configured to deny access to the infected file, quarantine it, or attempt to repair it. This provides a critical layer of defense against malware entering the corporate network via the central file repository.

Data Encryption and WORM for Compliance

For organizations with highly sensitive data or stringent regulatory requirements, data encryption is a necessity. The E20-390 Exam tests knowledge of Isilon's data-at-rest encryption (D@RE) capabilities. Isilon supports D@RE through the use of self-encrypting drives (SEDs). In a cluster equipped with SEDs, all data written to the drives is automatically encrypted by the drive's hardware. The encryption keys themselves are managed by an external Key Management Interoperability Protocol (KMIP) compliant key manager, such as Gemalto SafeNet KeySecure. This ensures a secure separation of duties, where the storage administrator manages the cluster and a security administrator manages the encryption keys.

Another critical feature for compliance is SmartLock, which provides Write-Once, Read-Many (WORM) data immutability. When a directory is configured as a SmartLock domain, files written into it become locked and cannot be modified or deleted for a specified retention period. This is essential for meeting legal and regulatory requirements for data retention, such as SEC Rule 17a-4. SmartLock has two modes: Enterprise mode, which allows a privileged administrator to undo the lock, and Compliance mode, which provides the highest level of protection where not even a root user can delete a file before its retention period expires.

Understanding NDMP for Backup and Recovery

While replication provides disaster recovery, traditional backup is still required for long-term archival and granular recovery. The standard protocol for backing up NAS devices is the Network Data Management Protocol (NDMP). The E20-390 Exam requires an understanding of how Isilon integrates with backup software using NDMP. OneFS supports a three-way NDMP configuration, which is the most efficient method. In this model, the backup application (Data Management Application, or DMA) instructs the Isilon cluster to start a backup. The Isilon cluster then reads the data directly from its disks and sends it across the network to the backup device (e.g., a tape library or a backup appliance), without the data having to pass through the backup server itself.

This direct data path significantly improves backup performance and reduces the load on the backup server and the network. Isilon supports various advanced NDMP features, such as token-based backups, which allow for parallel backup streams to improve performance, and file-level recovery from block-based backups. An implementation engineer needs to understand how to configure NDMP on the Isilon cluster, manage authentication credentials, and work with backup administrators to ensure that the data on the cluster is being backed up reliably and efficiently.

Advanced Performance Analysis

While Part 2 introduced basic monitoring, the E20-390 Exam also touches upon more advanced performance analysis and tuning. This involves moving beyond the high-level dashboard and using tools to investigate the underlying causes of performance issues. The isi statistics command in the CLI is incredibly powerful, offering deep insights into various subsystems. For example, isi statistics protocol can break down I/O operations by protocol, client IP address, and even by user, helping to identify a "noisy neighbor" that might be consuming an unfair share of resources.

Similarly, isi statistics drive can show the performance of individual drives, which can help pinpoint a failing or slow disk. Another key area is cache performance. The command isi statistics heat can show which files are the "hottest" or most frequently accessed, which is useful for verifying that SmartPools policies are correctly placing high-demand data on the fastest storage tier. A proficient engineer knows how to use these command-line tools to follow a methodical troubleshooting process, starting from a high-level symptom and drilling down to find the root cause of a performance problem.

Non-Disruptive Operations and Upgrades

One of the most significant advantages of the Isilon scale-out architecture is its ability to perform maintenance and upgrades without requiring downtime. This concept of non-disruptive operations is a recurring theme in the E20-390 Exam. Because every node is a peer and OneFS is a distributed file system, individual nodes can be taken offline for maintenance (e.g., to replace a failed component) while the rest of the cluster remains online and continues to serve data. The cluster's built-in data protection ensures that all data remains accessible even with a node offline, provided the configured protection level is not exceeded.

The same principle applies to software upgrades. OneFS supports rolling upgrades, where the new software version is applied to one node at a time. The node is rebooted, rejoins the cluster running the new code, and the process moves to the next node. During this entire process, which can take several hours for a large cluster, the cluster remains online and available for client access. This capability is a massive operational benefit compared to traditional scale-up systems that often require a planned outage window for software updates. Understanding the process and prerequisites for these non-disruptive operations is essential.

The Path to Isilon Specialization

This third part of the series has explored the advanced features that make Isilon a true enterprise-grade storage platform. We have covered how to optimize storage cost and performance with SmartPools and CloudPools, and how to secure the environment with RBAC, encryption, and auditing. We also discussed integrations for antivirus and backup, as well as the principles of advanced performance analysis and non-disruptive operations. These topics represent a higher level of mastery over the Isilon ecosystem and are critical for differentiating a basic administrator from a certified implementation specialist.

With the foundations from Part 1 and the core administration skills from Part 2, this exploration of advanced services provides a more complete picture of what is required for the E20-390 Exam. The final parts of our series will shift focus to troubleshooting common issues, preparing for the exam itself with practice scenarios, and looking at real-world implementation case studies. By combining architectural knowledge with practical administrative skills and an understanding of these advanced features, you will be well-equipped to tackle the challenges of both the certification exam and real-world Isilon deployments.

A Methodical Approach to Troubleshooting

When an issue arises on an Isilon cluster, a structured and methodical approach to troubleshooting is far more effective than random guesswork. This is a mindset that the E20-390 Exam seeks to validate. The first step is always to clearly define the problem. Is it a performance issue, a connectivity problem, a permission error, or something else? Gather as much information as possible from the end-user or application owner, including error messages, timestamps, and the specific workflow that is failing. Once the problem is defined, the next step is to determine the scope. Is the issue affecting a single user, a group of users, all clients on a specific network, or the entire cluster?

With the problem defined and scoped, you can begin to form a hypothesis. For example, if a single user cannot connect, the hypothesis might be an authentication or network issue specific to that user's client. If all users experience slow performance, the hypothesis might be a cluster-wide resource constraint. The next phase is to test the hypothesis using the various diagnostic tools available in OneFS. Based on the results of your tests, you either confirm and resolve the issue or refine your hypothesis and test again. This iterative process of defining, scoping, hypothesizing, and testing is fundamental to efficient problem resolution on any complex system, including Isilon.

Troubleshooting Client Connectivity Issues

Client connectivity problems are one of the most common issues an Isilon administrator will face. For the E20-390 Exam, you need to be able to diagnose why a client cannot access a share or export. The troubleshooting process should start at the client and work towards the cluster. First, verify basic network connectivity. Can the client ping the SmartConnect Service IP (SSIP) of the Isilon cluster? Can it perform a DNS lookup of the SmartConnect FQDN? DNS issues are a frequent cause of connection failures. Using a tool like nslookup to verify that the FQDN resolves to the correct IP addresses is a critical first step.

If basic network connectivity is confirmed, the next layer to investigate is authentication. Is the user providing the correct credentials? For SMB, is the client machine properly joined to the Active Directory domain? For NFS, does the client's IP address match a rule in the NFS export? OneFS logs are invaluable for diagnosing these issues. The log file /var/log/lsassd.log provides detailed information about authentication attempts against providers like Active Directory. Examining this log can reveal issues like failed Kerberos tickets or incorrect usernames. Similarly, checking the cluster's event logs (isi events) can show specific errors related to failed connection attempts.

Diagnosing Performance Problems: Latency and Throughput

Performance issues can be challenging to diagnose because they can have many root causes. The E20-390 Exam requires an understanding of how to differentiate between various types of performance problems. A key distinction is between latency and throughput. Latency refers to the time it takes to complete a single I/O operation, while throughput refers to the total amount of data that can be moved per second. An application might suffer from high latency even if overall cluster throughput is low, which is common for workloads that involve many small file metadata operations. Conversely, a single client performing a large file copy might saturate the network, causing a throughput bottleneck.

The tool of choice for investigating these issues is InsightIQ, or the isi statistics command for real-time analysis. When troubleshooting, it is important to analyze the "four main food groups" of storage performance: CPU, memory (cache), network, and disk. The isi statistics system command provides a high-level view of CPU utilization and network traffic. If CPU is consistently high, isi statistics protocol can help identify which clients or protocols are driving the load. If network throughput seems to be a bottleneck, you might investigate the client's network connection or the link aggregation configuration on the cluster. High disk I/O could point to a cache-miss-heavy workload that may benefit from adding SSDs.

Analyzing OneFS Log Files

OneFS generates a wealth of log files that are essential for deep-dive troubleshooting, and familiarity with their locations and contents is expected for the E20-390 Exam. Most logs are located in the /var/log/ directory on each node. While some logs are unique to a specific node, many critical logs are aggregated and synchronized across the cluster. The isi_for_array command is a powerful utility that allows you to run a command, such as searching a log file with grep, on all nodes simultaneously. This is invaluable for finding events that may have occurred on any node in the cluster without having to log in to each one individually.

Some of the most important log files include /var/log/messages, which contains general system-level events and hardware alerts. As mentioned earlier, /var/log/lsassd.log is crucial for authentication issues. The /var/log/lwiod.log contains detailed information on SMB protocol operations. For NFS, the nfs.log can provide insights. The cluster's event log system provides a consolidated, human-readable view of important alerts and can be viewed with the isi events command. Knowing where to look for specific types of error messages is a skill that can dramatically reduce the time it takes to resolve an issue.

Hardware Troubleshooting and Support

While Isilon is designed for high availability, hardware failures can and do occur. The E20-390 Exam will expect you to know the process for identifying and handling common hardware faults. OneFS continuously monitors the health of all hardware components, including drives, power supplies, network interfaces, and memory modules. When a component fails, the cluster automatically generates a high-priority event alert. These alerts are visible in the WebUI, the CLI via isi events, and can be configured to be sent out via email or SNMP to a monitoring system. The system will also automatically mark the failed component as faulty.

For a failed drive, the FlexProtect system will automatically begin a "reprotect" or "rebuild" job to recalculate the missing data and write it to the available free space in the cluster, ensuring the data returns to its configured level of protection. The role of the administrator is to identify the failed component, which the system will clearly flag by node number and component ID, and then follow the documented procedure for replacement. For critical issues, it is essential to know how to gather a comprehensive log set from the cluster using the isi_gather_info command. This command bundles all relevant logs and system configuration data into a single file that can be sent to Dell EMC support for analysis.

Optimizing SMB and NFS Performance

Beyond fixing problems, a key skill for an implementation engineer is performance tuning. For the E20-390 Exam, you should be familiar with common tuning parameters for both SMB and NFS. For SMB, performance can often be improved by enabling SMB3 and its advanced features like Multichannel. SMB Multichannel allows a client with multiple network interfaces to establish multiple connections to the Isilon cluster for a single session, aggregating the bandwidth and providing resiliency. On the Isilon side, ensuring that you have enough IP addresses in your SmartConnect pool and that clients are being distributed evenly across nodes is also important.

For NFS, especially in high-performance computing environments, tuning the read and write block sizes (rsize and wsize) on the client-side mount options can have a significant impact. Matching these sizes to the Isilon cluster's optimal I/O size can improve efficiency. On the cluster itself, enabling and tuning the NFS data cache can reduce latency for frequently read data. Additionally, separating different NFS workloads onto different network subnets and SmartConnect zones can help isolate traffic and prevent one high-demand application from impacting others. The key is to understand the specific I/O profile of the application and tune the parameters accordingly.

Tuning SmartPools for Optimal Data Placement

SmartPools is not just a set-it-and-forget-it feature; it can be tuned to optimize performance and cost. The E20-390 Exam may test your understanding of these tuning concepts. The most important aspect is designing file pool policies that accurately reflect the data lifecycle of your workloads. For example, if you know that a certain project's data is only actively used for 30 days, creating a policy to move that data to a lower-cost tier after 35 days is a simple and effective optimization. It is also important to consider the I/O impact of the SmartPools job itself. By default, it runs at a low priority, but its schedule and impact level can be adjusted.

Another tuning consideration is the "spillover" setting. By default, if a specific tier or node pool becomes full, new writes destined for that pool can "spill over" to another available pool. While this ensures that writes never fail due to a full tier, it might not be desirable if you have strict data placement requirements. Understanding how to manage this behavior, for example, by disabling spillover for certain pools, is an important administrative skill. Regularly reviewing the File System Analytics reports to see if your data is landing on the correct tiers is also a crucial part of the ongoing tuning process.


Go to testing centre with ease on our mind when you use EMC E20-390 vce exam dumps, practice test questions and answers. EMC E20-390 VNX Solutions Specialist for Implementation Engineers certification practice test questions and answers, study guide, exam dumps and video training course in vce format to help you study with ease. Prepare with confidence and study using EMC E20-390 exam dumps & practice test questions and answers vce from ExamCollection.

Read More


SPECIAL OFFER: GET 10% OFF

ExamCollection Premium

ExamCollection Premium Files

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 10% Off Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.