HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vcehttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.htmlHP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vceDirkZhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-378817Q91 (which view to select to create a baseline)<br /> answer is C : "admin" <br /> <br /> http://www.vmware.com/pdf/vsp_vum_40_admin_guide.pdf :<br /> Creating Baselines<br /> You can create patch and upgrade baselines to meet the needs of your specific deployment by using the<br /> New Baseline wizard. Creating additional, customized baselines allows patches to be grouped into logical sets.<br /> You create baselines in the Update Manager Client Administrator's view.Sunday, March 10, 2013 12:11 AM UTDirkZhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-378813Q73 is D: "verify and update system ROM" (before adding a processor)<br /> From HP Support:<br /> Advisory: SYSTEM ROM UPGRADE RECOMMENDED Before Adding Processors to Some ProLiant Servers or the System May Stop Responding During Power-On Self-Test (POST) with an "805-Unsupported Processor Detected" MessageSaturday, March 09, 2013 11:49 PM UTMohammed Alihttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-378047I revised this dump and passed the exam today. I can say most of questions are from this dump but I'm not sure about the whole dump answers whether correct or not. I scored 72Thursday, March 07, 2013 1:36 PM UTxxxxhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377623A have uploaded new dump with this questions but I have changed many answers.<br /> Please, review it. I didn`t try to pass the exam with itWednesday, March 06, 2013 11:08 AM UTDaulexhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377593Did you use our correction from this comments ?Wednesday, March 06, 2013 10:09 AM UTjosh00bhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377591Yes Daulex, all questions of dump are in the real exam, <br /> I passed this exam yesterday (failded) because many answers are wrongWednesday, March 06, 2013 10:06 AM UTTeemohttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377465Question 152 I think the answer is C<br /> <br /> You may remove and replace a disk from these hot-swap storage systems after checking that the Safe to Remove status indicates "Yes" for the drive to be replaced. ( copied from "P4000 SAN Solution User Guide " Page 46)<br /> http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03035314/c03035314.pdfTuesday, March 05, 2013 10:41 PM UTxxxxhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377325q17 is DTuesday, March 05, 2013 2:57 PM UTxxxxhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377323Also:<br /> q132: D<br /> q146: A, E<br /> q149: C<br /> q152: A<br /> q157:BTuesday, March 05, 2013 2:56 PM UTDaulexhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377249Q114. I think answer is C<br /> The HP CTO (Configure to Order) Program is designed to provide customers with a production of equipment manufactured tailor-made to their needs.<br /> Optimized Care Optimized Care Package: Supports maintaining servers at optimum performance availability HP ProLiant Server Hardware InstallationTuesday, March 05, 2013 10:52 AM UTDaulexhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377245Q112. Answers A, B are correct,. But can someone explain why D. For FlexFabric is "Maximum transmission unit (MTU) of up to 9216 bytes (jumbo frames)"Tuesday, March 05, 2013 10:43 AM UTDaulexhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377219Q96. Answer was B, but I think is D<br /> Answer was B, but I think is D<br /> <br /> Disaster Tolerance: Is some cluster features<br /> Disaster Recovery: You need to have everything on another site. It is replication features<br /> Business Continuity: Is Disaster Recovey + some software features.<br /> System Recovery: Recovery sistem prom bacup.Tuesday, March 05, 2013 9:56 AM UTDaulexhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377209Q.86. Answer A is 100 % true. But answer D as I know is not.<br /> "vcutil -a" command only has "version, update, report, discover" option.<br /> Command vcsu has that option, Syntax: "vcsu -a configbackup .."<br /> So there is just one answer ATuesday, March 05, 2013 9:28 AM UTDaulexhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377196Q80. Is tricky one. Question is about "IT infrastructure security management". So probably answers are B,C but not to use VLAN1 is also very important ..Tuesday, March 05, 2013 9:09 AM UTSeriouslyPlayfulhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-377192Using HP Agentless Management, which components offer pre-failure alerting?<br /> Correct Answer is : Memory<br /> <br /> Answer is in this link in the first video: <br /> http://h30507.www3.hp.com/t5/Coffee-Coaching-HP-and-Microsoft/HP-ProLiant-Gen8-Agentless-Management-Overview/ba-p/108579<br /> <br /> http://www.youtube.com/watch?v=XDCBd_NeOuY&feature=player_embeddedTuesday, March 05, 2013 9:03 AM UTjosh00bhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376926Q 90: My answer are C "HP SUM" (not B)<br /> Because the Active Health System collects data from iLO 4 itself, System ROM, Smart Array, NIC, and power supply firmware, hardware components, and optional OS agents. It collects approximately 1,600 unique data items<br /> http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03207602/c03207602.pdf PMonday, March 04, 2013 2:55 PM UTjosh00bhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376900Q15 : My answer are C (not D)<br /> http://www.tricksguide.com/how-to-expand-array-extend-logical-drive-raid-hp-acu.html<br /> Q146 : My answers are A and E (not D,E)<br /> http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&taskId=125&prodSeriesId=5177949&prodTypeId=3709945&prodSeriesId=5177949&objectID=c03385293Monday, March 04, 2013 2:04 PM UTseriouslyplayfulhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376849After a power failure, how long will the data be retained on the cache of an FBWC of a Smart Array Controller <br /> Correct answer is :indefinitely<br /> The HP flash-backed write-cache (FBWC) system offers important advantages over battery-backed write-cache (BBWC) systems. HP designed the FBWC with NAND1 flash devices so that power is not required to retain cache data. There is no longer a 48-hour battery life limitation and the data will be posted to the disk drive the next time you power up the server. HP has engineered the FBWC to function with long-life super-capacitors (Super-caps) instead of a battery. The Super-cap is only used to power the FBWC system during data backup. The result is that the FBWC retains cache data regardless of server power states and you can adjust maintenance and replacement schedules to accommodate the longer Super-cap lifecycle. Figure 1-1 displays the FBWC module and the Super-cap housing. <br /> <br /> http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02231971/c02231971.pdfMonday, March 04, 2013 11:06 AM UTSergehttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376844Questions matched but still many wrong answers in this vce. I only got 68%Monday, March 04, 2013 11:01 AM UTDaulexhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376547Q17. FBWC is a flash based cache module that does not have battery limitation of how long it can retain what is written to the module. So answer is not E. Maybe D<br /> Q24. Hot-asie = Racks face back to back. So answer is C<br /> Q33.Cold-asie = Racks face front to front. so answer is D<br /> Q60 Answer C not A<br /> Q73 Answer B not D. They did not say that they will put different processor.<br /> Q122. My answers are D, E<br /> Q134 My answers are B, F. Aluminium to avoid !!!!<br /> Q137 My answer B,D. As I understand P10000 is not proliant base<br /> Q146. I really not sure. I wiil use all HBA adapter, why to change MPIO setting.<br /> Q147. My answers is D, E Different voltage DIMM will work on higher voltage<br /> Q150. A, E 100%<br /> Q157. my answer is BSunday, March 03, 2013 9:12 AM UTE100https://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376491People I have laid out the issues that will be on the exam. Just here all the time trying to post questions, but examination has three options. If you ever see one option then you're in luck.Sunday, March 03, 2013 4:04 AM UToleolehttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376453150 Which services does HP offer to help you review current firmware levels and develop an appropriate management strategy? (Select two) <br /> &bull; HP BladeSystem Firmware and Driver Gap Analysis<br /> &bull; HP BladeSystem Firmware and Driver Update Process Review<br /> <br /> http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02225412/c02225412.pdf p8Saturday, March 02, 2013 9:21 PM UTcrammerhttps://www.examcollection.com/hp/HP.BrainDump.HP0-S35.v2013-02-29.by.E100.157q.vce.file.html#comment-376022Great Dump, although some answers are wrong to my opinion.<br /> <br /> DFriday, March 01, 2013 10:44 AM UT