• Home
  • HP
  • HP0-S35
  • HP.BrainDump.HP0-S35.v2013-02-22.by.SeriouslyPlayful.63q.vce

Pass Your HP HP0-S35 Exam Easy!

Get 100% Real Exam Questions, Accurate & Verified Answers By IT Experts

Fast Updates & Instant Download!

Certification Exam: HP0-S35 (Implementing HP BladeSystem Solutions)

Download Free HP0-S35 Exam Questions

Exam HP0-S35 - Implementing HP BladeSystem Solutions
Size: 5.19 MB
Posted Date: Sunday, February 24, 2013
# of downloads: 30
Free Download:
  Download Free HP0-S35 Exam Questions
Exam
HP0-S35 - Implementing HP BladeSystem Solutions
Size
5.19 MB
Posted Date
Sunday, February 24, 2013
# of downloads
30
Comments
* The most recent comment are at the top
  • www
  • United Kingdom
  • Feb 27, 2013

QUESTION 30 An engineer reviews a Virtual Connect profile configuration and finds that all of the defined network cards do not have mapping formation
What could cause this problem?
A. The cable does not connect to the switch
B. The profile has not been assigned to the server
C. The corresponding server has been switched off
D. The network selected has no valid uplinks

QUESTION 31 Which resource can be used to identify supported third-party SAN configurations for HP BladeSystems?
A. HP SAN Design Reference Guide
B. SNIA Compatibility Reference Tables
C. HP Heterogeneous SAN Design Guide
D. SNIA SMI-S Specifications Support Matrix

  • Feb 27, 2013
  • www
  • United Kingdom
  • Feb 27, 2013

QUESTION 26 In a P4000 system, which Network RAID level is required to power off the drive in the Central Management Console before removing it?
A. RAID 0
B. RAID 1
C. RAID 5
D. RAID 50

QUESTION 27 Which log or report is used to verify the Memory Serial Presence Detect (SPD) information on a BladeSystem Gen8 server?
A. iLO Diagnostics Log
B. Onboard Administrator (OA) ShowAII report
C. Integrated Management Log (IML)
D. Insight Diagnostics, Survey report from HP Intelligent Provisioning tool

QUESTION 28 What can you use to transfer information over a power distnbution infrastructure consisting of an iPDU and extension bars
A. mini USB power connection
B. power line communis (PLC)
C. Power over Ethernet connection (PoE)
D. dedicated null modem senal cable

QUESTION 29 You are creating an action plan to troubleshoot an inaccessible EVA LUN. Which steps should your action plan contain ? (select three)
A. Check Server MBA ports
B. Check Server Array controller
C. Check EVA Vdisk presentation
D. Check SAN switch zoning
E. Check SAN switch ifmode.

  • Feb 27, 2013
  • hqid
  • Germany
  • Feb 27, 2013

QUESTION 22 A customer adds a BL460c G7 blade to a c-Class enclosure with Virtual Connect (VC) installed, boots the server, and sets PXC on the second NIC m the ROM Base Setup Utility (RBSU) The blade connects, but due to a network issue, does not complete, and the blade is cold booted Now the blade never connects to the HP Insight Control Deployment Server.
What is needed to enable the Wade to always connect to the deployment server?
A. Recreate the VC profile with PXF enabled on the second NIC.
B. Set PXE on the second NIC in tho VC profile
C. Set PXE on the first NIC in the server profile.
D. Enable Smartl ink on the VC profile on the second NIC

QUESTION 23 A customer has an HP BtadeSystem c7000 environment and wants to add HP external storage Which HP resources can be used to validate design compatibly? (Select three.)
A. SAN Design Reference Guide
B. Insight Online
C. Stengel Port configuration Knowledge
D. Product Datasheets
E. Support Center
F. Storage Sizer

QUESTION 24 An HP BLc 4X QDR InfiniBand switch is installed in Bays 3 and 4 in a c7000 enclosure What is the maximum number of downlink ports that it for connections to Wade servers?
A. 8
B. 16
C. 32
D. 64

QUESTION 25 A customer wants to add a second dual port Fibre Channel adapter to a BL460c Gen 8 server in an HP BladeSystem c7000. What is the
A. FC HBA in Mezzanine two with FC interconnects in slots seven and eight
B. FC HBA in Mezzanine two with FC interconnects in slots three and four
C. FC HBA m Mezzanine two with FC interconnects in slots five and seven
D. FC HBA in Mezzanine two with FC interconnects in slots five and six

  • Feb 27, 2013
  • hqid
  • Germany
  • Feb 27, 2013

QUESTION 18 You configured HP SIM to send email alerts if a system crashes in a LAWMAN environment You occasionally receive email alerts with false no unreachable system, even if the system has been up and running without any crash or hang
What should you do first to correct the problem?
A. Customize the Timeout and Retries values on the Discovery page
B. Customize the Timeout and Retries values for that specific system
C. Reboot the server and apply the latest Windows and HP patches
D. Customize the Retries value from 1 to 5.

QUESTION 19 Using HP Agentless Management, which components offer pre-failure alerting?
A. processors
B. memory
C. power supplies
D. Fans

QUESTION 20 In an HP BL460c Gen8 server, which NIC RBSU personality setting allows the Converged Network Adapter to connect to the Fibre Channel storage?
A. Iscsi
B. FCIP
C. FC Connect
D. FCoE

QUESTION 21 You are preparing an Intel based UP ProLiant Gen8 server for installation of a hyperwsor. Which advanced R3SU settings should be set? (Setect two)
A. Visualization Technology Support enabled
B. adjacent sector prefetch disabled
C. Intel Core C3 state enabled
D. half physical cores per processor disabled
E. No-Execute Memory Protection disabled
F. No-Execute Memory Protection enabled

  • Feb 27, 2013
  • hqid
  • Ukraine
  • Feb 27, 2013

QUESTION 14 How can you access the memory DIMM Serial Presence Detect (SPD) data failure log in an HP ProLiant BL460c Gen8 server?
A. HP Insight Diagnoses
B. SmartStart
C. iLO Web Interface
D. RBSU

QUESTION 15 Which settings can you configure using EBIPA? (Select two.)
A. serial number
B. DNS address
C. NIC teaming address
D. enclosure name

QUESTION 16 Which statements about HP Virtual Connect FlexFabnc ethernet connectivity are correct? (Select three.)
A. it drops all incoming Jumbo Frames
B. it allows aggregation of uplinks to data center networks
C. it blocks all Link Layer Discovery Protocol trafic
D. it support VLAN tagging on egress or pass-through of VLAN tags in tunneled node
E. it does not participate in the data center Spanning Tree Protocol

QUESTION 17 After a power failure, how long will the data be retained on the cache of an FBWC of a Smart Array Controller'?
A. FBWC does not protect cache data with power failure
B. indefinitely
C. 24 hours
D. 48 hours
E. 72 hours

  • Feb 27, 2013
  • seriouslyplayful
  • Cyprus
  • Feb 27, 2013

QUESTION 10 A customer has a standard HP Proliant BL680c server and wants to integrate an online mirror split in local storage RAID1. Which action needs to be performed?
A.Expand the array with two additional disk drives.
B.Add 1 GB Flashed-backed write cache
C.Upgrade to an HP P711 Smart Array controller.
D.Apply an HP Smart Array Advanced pack license.

QUESTION 11 An HP BladeSystem c7000 Insight Display backlight is flashing. What can cause this?
A.normal status, flashing as heartbeat
B.user logged in to iLO console
C.status that needs attention
D.user logged in to Onboard Administrator

QUESTION 12 Acustomer adds a BL460c G7 Blade to a c-Class enclosure with virtual Connect (VC) installed, Boots the server and sets PXE on the second NIC..... Rom-Based Setup Utility (RBSU). The blade connects, but due a network issue, does not complete, and the blade is cold booted. Now .. Insight Control Deployment Server.

What is needed to enable the blade to always connect to the deployment server?
A.Enable SmartLink on the VC profileon the second NIC.
B.Recreate the VC profile with PXE enabled on the second NIC.
C.Set PXE on the second NIC in the VC profile.
D.Set PXE on the first NIC in the server profile

QUESTION 13 A customer has an LTO-4 tape drive connected to an HP DL380 server. The customer wants to integrate a new backup solution.... enclosure and maximize capacity.
Which HP protuct should be recommended?
A.SB920c
B.SB3000c
C.x3800sb
D.SB1760c

  • Feb 27, 2013
  • seriouslyplayful
  • Cyprus
  • Feb 27, 2013

6) Which enhancements were added to the HP iLO Management Engine of an HP ProLiant Gen8 server? (Select Two)
A.HP Virtual Media
B.HP Remote Console
C.Video Replay
D.Agentless Management
E.Embedded Remote Support


7) Which memory protection is supported on a BL460c Gen8 Blade Server? (Select two)
A.Memory Non-Lockstep Mode
B.Advanced ECC
C.Memory Lock Step Mode
D.Hot Plug Raid Mirror
E.Memory parity checking


8) Using HP Agentless Management, which components offer pre-failure alerting?
A.power supplies
B.memory
C.processors
D.fans


9) What are the major advantages of the GUID Partition table (GPT) over the Master Boot Record (MBR) ? (Select two)
A.it provides added security with 1024 encryption
B.it provides added security with 2048 encryption
C.it not restricted to a disk partition's size of 2 TB
D.it supports Solid State Drives (SSD)
E.it provides redundancy

  • Feb 27, 2013
  • anonymous (seriouslyplayful)
  • Cyprus
  • Feb 27, 2013

3) What can you use to transfer information over a power distribution infrastructure consisting of an iPDU .....
A.Power over Ethernet connection (PoE)
B.mini USB power connection
C.dedicated null modem serial cable
D.power line communications (PLC)

4)What describes hot-aisle containment for rack placement in a data center?
A.Two rows are positioned back to back
B.Two rows are positioned front to front
C.Two rows are positioned front to back
D.Two rows are positioned back to front

5)Which file system is supported on the VMware vShere ESXi 5 hypervisor host? (select two)
A.NTFS
B.ext2
C.ext3
D.VMFS v3
E.VMFS v5

  • Feb 27, 2013
  • anonymous (seriouslyplayful)
  • Cyprus
  • Feb 27, 2013

Guys My friend took the exam yesterday. THese are the new questions. Unfortunately the photos missed a couple of words towards the end of the sentence at the end of the screen hence some words missing. I will be posting them here so that we all look at them and find solutions.(if there is .... it means a couple of words are missing)

1)What is the definition of Recovery Point Objective (RPO)?
A.point in the process code that needs to be recovered
B.amount of time a recovery process must wait before it ...
C.amount of time a recovery process may take
D.amount of data that can be unrecoverable


Which component is only required on the monarch blade module of an HP Integrity i2 server?
A.scalable memory buffers
B.memory
C.ICH mezanine card
D.management processor

  • Feb 27, 2013
  • good.morning
  • Germany
  • Feb 26, 2013

About the tool - but when i read in the Paper to the HP SUM - i found that :

This argument generates a report The following report file is generated:
that lists all installed firmware,
/installed_report
HPSUM_Installed_Report_<datatime>.xml ,
software, and driver versions .html, or .csv.
installed on targets.

  • Feb 26, 2013
  • good.morning
  • Germany
  • Feb 26, 2013

About the Question : which HP tool collects most information

I think it´s not Active Health System - this is not a tool - ist included in ILO and you can read it with the Viewer and works only with Gen8 Systems. I think is HPS Report - this is a "Tool/Utiliy"

  • Feb 26, 2013
  • good.morning
  • Germany
  • Feb 26, 2013

For the Question :

At a customer meeting, a concern was raised about IT infrastructure security management. In planning the solution for this concern, which critical area should be addressed?

I Think it´s A & C - because - A say the User ID und the "LAN" and C say the Management Passworts - so we habe USER ID & Password & LAN

D - i think it´s not correct - because a "Virtual Network with VLAN 1" doesn´t exist. You can change the Native VLAN to anothe ID then 1 - but no Virtual Network with ID 1 exists.

  • Feb 26, 2013
  • anonymous (seriouslyplayful)
  • Cyprus
  • Feb 26, 2013

At a customer meeting, a concern was raised about IT infrastructure security management. In planning the solution for this concern, which critical area should be addressed?

In this question,when i took exam last week, there was single answer, not multiple. I have to photo to prove it. But from my understanding question doesn't require us to suggest solution to fix problem (solution would be in that case "Isolated management LAN access" ). From my understanding question needs us to point out which is the problem, not the solution. So i think answer is A. The use of a common user ID and common IP subnet with the production LAN.

I think HP is trying to confuse us by the way it is posting this question. We could all be correct depending how we interprit the question.

  • Feb 26, 2013
  • E100
  • Kazakhstan
  • Feb 26, 2013

the people I talk to in this examination. There were 90% of new issues. Later, lay idit new questions for the exam with this dump would be a loss of money and time.

  • Feb 26, 2013
  • Maya
  • South Africa
  • Feb 25, 2013

Hi Mashaar:

can you explain me why C isn't a valid possibility? ...

http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c03520794/c03520794.pdf

- Deployment of software for single or one-to-many HP ProLiant servers (supported in Windows
and Linux environments).

I think you might have the answer here. HP normally relies on their own homogenized method. Doing all the servers at once would be a typical approach

Changing my answer to C

  • Feb 25, 2013
  • Maya
  • South Africa
  • Feb 25, 2013

Conflicting answers, which one to choose?

At a customer meeting, a concern was raised about IT infrastructure security management. In planning the solution for this concern, which critical area should be addressed?

A. The use of a common user ID and common IP subnet with the production LAN.
B. Isolated management LAN access.
C. The use of a common password to access all management components.
D. A virtual network with VLAN ID 1

Multiple answers suggested C & D - Both use of common passwords and utilizing VLAN ID 1 are not secure at all.
Single choice suggests A

  • Feb 25, 2013
  • MaaShar
  • Belgium
  • Feb 25, 2013

Maya,

can you explain me why C isn't a valid possibility? Because I think C is the correct answer, unless you can explain me why Windows and RHEL can't be updated at the same time. Booting from the ISO is possible indeed, but I don't think it is the fastest. But again, I can't give you the 100% correct answer as well :(

  • Feb 25, 2013
  • Maya
  • South Africa
  • Feb 25, 2013

Magic answer?

A customer wants to update the SPP on five Windows 2008 R2 and five RHEL6 servers running in an HP Bladesystem C7000 chassis.

What is the fastest way to achieve this?

A. Boot each server from the SPP DVD, using the Onboard Administrator
B. Run the SPP on each server using the rcmd command on Windows and remote SSH script on RHEL
C. Update all targets remotely at the same time from one instance of HP Smart Update Manager from a client
D. Update all Windows servers from one client using HP Smart Update Manager followed by all RHEL servers

It seems that A and D might be possible answers. Which one is fastest (easiest)

  • Feb 25, 2013
  • MaaShar
  • Belgium
  • Feb 25, 2013

Maya,

funny how things can be interpreted among us :)
But again I have to change my opinion and I think it is final now. See this link:
http://www.intel.com/content/www/us/en/io/quickpath-technology/quickpath-technology-general.html

You will see this sentence:
- Intel® QuickPath Technology uses Intel® QuickPath Interconnect, which provides high-speed, point-to-point links inside and outside of the processor. In contrast to parallel buses, these links speed up data transfers by connecting distributed shared memory, the internal cores, the I/O hub, and other Intel® processors.

Which means also transport between cores internally.
I think we can conclude now 'Quickpath interconnect' is the correct answer here?

  • Feb 25, 2013
  • Maya
  • South Africa
  • Feb 25, 2013

The way I understand it, Crossbar is not a technology name, but a switch that assist in communication between processors, memory etc, allowing inter core & inter CPU communication. QPI, FSB & HT are all types of crossbar switches.


www.site.uottawa.ca/~mbolic/ceg4131/Report Crossbar switches.pdf

A. Intel Xeon 7500 architecture
The Intel Xeon 7500 series processor architectures uses an
8 port crossbar switch which implements the Intel QuickPath
Interconnect (QPI) and routing layers. The Intel QPI is
point-point interconnection link developed by Intel [1] to
compete with HyperTransport. Prior to using QPI the Intel
architecture was using the Front Side Bus (FSB) [2] which
was the bus that carried data between CPU and the memory
controller(northbridge) and I/O controller(southbridge).
The off-chip single memory controller often was the
bottleneck which prevented faster CPUs from improving
the overall performance of the system. Now, with crossbar
implementation the microprocessor were able to integrate the
northbridge on-chip for faster access.

  • Feb 25, 2013
  • Maya
  • South Africa
  • Feb 25, 2013

Refer edv's answer

QUESTION 16
Which KVM is assigned Master Status in a cascaded configuration?

I missed the "IP" part of description when I did my initial research. The IP switch must always be the master.

So yes, I agree, C must be the answer

  • Feb 25, 2013
  • MaaShar
  • Belgium
  • Feb 25, 2013

kkk,

http://www.examcollection.com/hp/HP.ActualAnswers.HP0-S35.v2013-02-19.by.LoL.63q.vce.file.html

The questions are in the comments because for some questions we can't remember all answers..

  • Feb 25, 2013
  • kkkk
  • United States
  • Feb 25, 2013

@MaaShar: Where is the dump with the other 26 questions?

  • Feb 25, 2013
  • MaaShar
  • Belgium
  • Feb 25, 2013

EDV,

many errors? we are all trying to find the correct answers.. just saying 'many errors' doesn't help us very much :) I think we've been able to sort out a lot of questions already. It's still possible there are some errors though, so it would be helpful to provide us the correct answer where you think we are wrong.

You may be right about the HP IP KVM Console switch: (page 4)
http://h18000.www1.hp.com/products/quickspecs/12464_div/12464_div.pdf

The question about the core-to-core transport mechanism you may be right as well :) Quickpath interconnect is between processors and crossbar switchs is between cores:
http://books.google.be/books?id=L9IDAAAAMBAJ&pg=PA30&lpg=PA30&dq=crossbar+switch+vs+quickpath+interconnect&source=bl&ots=AQSQVDQh6F&sig=6jHFAWwyLVD9rcP9984MwGrO5zU&hl=nl&sa=X&ei=7kErUY6EOM-4hAeBi4CoBQ&ved=0CCsQ6AEwAA#v=onepage&q=crossbar%20switch%20vs%20quickpath%20interconnect&f=false

In another dump we also posted 26 other questions, can you please involve there as well so we can find the correct answers for these questions? Thanks in advance!

  • Feb 25, 2013
  • edv
  • Russian Federation
  • Feb 25, 2013

QUESTION 6
What is the name of the core-to-core transport mechanism used in Intel XEON processors?

What a you think about this?
http://www.intel.com/content/dam/doc/white-paper/quick-path-interconnect-introduction-paper.pdf (Crossbar Router, Figure 7, page 8)
http://www.intel.com/content/dam/www/public/us/en/documents/datasheets/xeon-e7-8800-4800-2800-families-vol-2-datasheet.pdf (Rbox, Crossbar Router, page 16)

Correct answer is "B"



and many errors..



HP employer upload this dump??? :)))

  • Feb 25, 2013
  • edv
  • Russian Federation
  • Feb 25, 2013

sorry, page 63

  • Feb 25, 2013
  • edv
  • Russian Federation
  • Feb 25, 2013

QUESTION 16
Which KVM is assigned Master Status in a cascaded configuration?

What a you think about this?
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00224485/c00224485.pdf (pge 67)

CAUTION: While cascading console switches, be sure that the console switch is cascaded below the HP IP
Console Switch. Undesirable operations might occur if these specific cascading sequences are not followed.

Correct anwer is "C"


I can upload my answers )))))

  • Feb 25, 2013
  • SeriouslyPLayful
  • Cyprus
  • Feb 25, 2013

These are the exact same questions I faced last Tuesday the 19th of February when i took this exam.

  • Feb 25, 2013

Add Comments

Introducing The New!

Exam Collection

Premium Membership
Premium

Get Unlimited Access to all
ExamCollection’s PREMIUM files

Learn More
Download Quality. ExamCollection Certified

Site Search:

Only Registered Members Can Download VCE Files or View Training Courses

Please fill out your email address below in order to Download VCE files or view Training Courses. Registration is Free and Easy - you simply need to provide an email address.

  • Trusted By 1.2M IT Certification Candidates Every Month
  • VCE Files Simulate Real Exam Environment
  • Instant Download After Registration.
Please provide a correct e-mail address
A confirmation link will be sent to this email address to verify your login.
Already Member? Click Here to Login

Log into your ExamCollection Account

Please Log In to download VCE file or view Training Course

Please provide a correct E-mail address

Please provide your Password (min. 6 characters)

Only registered Examcollection.com members can download vce files or view training courses.

Registration is free and easy - just provide your E-mail address. Click Here to Register

Summer Sale: 20% OFF!

ExamCollection Premium

ExamCollection Premium Files

Get Unlimited Access to all ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads
Enter Your Email Address to Receive Your 20% OFF Discount Code
A Confirmation Link will be sent to this email address to verify your login
We value your privacy. We will not rent or sell your email address

Summer Sale: 20% OFF!

Use Discount Code:

SUMMER2020

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Next

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.